-
1
-
-
84984082388
-
Scapular shape and primate classification
-
Ashton, E.H., Oxnard, C.E., Spence, T.F., 1965. Scapular shape and primate classification. Proceedings of the Zoological Society, London 145, 125-142.
-
(1965)
Proceedings of the Zoological Society, London
, vol.145
, pp. 125-142
-
-
Ashton, E.H.1
Oxnard, C.E.2
Spence, T.F.3
-
2
-
-
0033218441
-
Variability of measurement of glenoid version on computed tomography scan
-
Bokor, D.J., O'Sullivan, M.D., Hazan, G.J., 1999. Variability of measurement of glenoid version on computed tomography scan. Journal of Shoulder and Elbow Surgery 8, 595-598.
-
(1999)
Journal of Shoulder and Elbow Surgery
, vol.8
, pp. 595-598
-
-
Bokor, D.J.1
O'Sullivan, M.D.2
Hazan, G.J.3
-
4
-
-
0035407670
-
Glenoid size, inclination, and version: An anatomic study
-
Churchill, R.S., Brems, J.J., Kotschi, H., 2001. Glenoid size, inclination, and version: an anatomic study. Journal of Shoulder and Elbow Surgery 10, 327-332.
-
(2001)
Journal of Shoulder and Elbow Surgery
, vol.10
, pp. 327-332
-
-
Churchill, R.S.1
Brems, J.J.2
Kotschi, H.3
-
5
-
-
0033760895
-
Morphological and mechanical analysis of the glenoid by 3D geometric reconstruction using computed tomography
-
Couteau, B., Mansat, P., Darmana, R., Mansat, M., Egan, J., 2000. Morphological and mechanical analysis of the glenoid by 3D geometric reconstruction using computed tomography. Clinical Biomechanics 15, S8-S12.
-
(2000)
Clinical Biomechanics
, vol.15
-
-
Couteau, B.1
Mansat, P.2
Darmana, R.3
Mansat, M.4
Egan, J.5
-
6
-
-
0026786765
-
The use of computerized tomography in the measurement of glenoid version
-
Friedman, R.J., Hawthorne, K.B., Genez, B.M., 1992. The use of computerized tomography in the measurement of glenoid version. Journal of Bone and Joint Surgery America 74 (A), 1032-1037.
-
(1992)
Journal of Bone and Joint Surgery America 74 (A)
, pp. 1032-1037
-
-
Friedman, R.J.1
Hawthorne, K.B.2
Genez, B.M.3
-
7
-
-
0032062257
-
Anthropometry of the scapula: Clinical and surgical considerations
-
Gallino, M., Santamaria, E., Doro, T., 1998. Anthropometry of the scapula: clinical and surgical considerations. Journal of Shoulder and Elbow Surgery 7, 284-291.
-
(1998)
Journal of Shoulder and Elbow Surgery
, vol.7
, pp. 284-291
-
-
Gallino, M.1
Santamaria, E.2
Doro, T.3
-
8
-
-
0003807831
-
-
Mosby-Wolfe Publishers, pp
-
Gosling, J.A., Harris, P.F., Humpherson, J.R., Whitmore, I., Willan, P.L., 1996. Human Anatomy Color Atlas and Text. Mosby-Wolfe Publishers, pp. 3.30-3.45.
-
(1996)
Human Anatomy Color Atlas and Text
-
-
Gosling, J.A.1
Harris, P.F.2
Humpherson, J.R.3
Whitmore, I.4
Willan, P.L.5
-
9
-
-
0020759032
-
A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
-
Grood, E.S., Suntay, W.J., 1983. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. Trans ASME Journal of Biomechanical Engineering 105, 136-144.
-
(1983)
Trans ASME Journal of Biomechanical Engineering
, vol.105
, pp. 136-144
-
-
Grood, E.S.1
Suntay, W.J.2
-
10
-
-
0033919801
-
Functional stability of the glenohumeral joint
-
Hess, S.A., 2000. Functional stability of the glenohumeral joint. Manual Therapy 5, 63-71.
-
(2000)
Manual Therapy
, vol.5
, pp. 63-71
-
-
Hess, S.A.1
-
11
-
-
54049156950
-
-
Ph.D. Thesis, Imperial College, University of London, United Kingdom
-
Hill, A.M., 2006. Passive stability of the glenohumeral joint. Ph.D. Thesis, Imperial College, University of London, United Kingdom.
-
(2006)
Passive stability of the glenohumeral joint
-
-
Hill, A.M.1
-
12
-
-
38049030075
-
Qualitative and quantitative descriptions of glenohumeral motion
-
Hill, A.M., Bull, A.M.J., Wallace, A.L., Johnson, G.R., 2008. Qualitative and quantitative descriptions of glenohumeral motion. Gait and Posture 27, 177-188.
-
(2008)
Gait and Posture
, vol.27
, pp. 177-188
-
-
Hill, A.M.1
Bull, A.M.J.2
Wallace, A.L.3
Johnson, G.R.4
-
13
-
-
0027656883
-
A method for the measurement of three-dimensional scapular movement
-
Johnson, G.R., Stuart, P.R., Mitchell, S., 1993. A method for the measurement of three-dimensional scapular movement. Journal of Clinical Biomechanics 8, 269-273.
-
(1993)
Journal of Clinical Biomechanics
, vol.8
, pp. 269-273
-
-
Johnson, G.R.1
Stuart, P.R.2
Mitchell, S.3
-
14
-
-
1242276500
-
Variations in glenoid rim anatomy: Implications regarding anchor insertion
-
Lehtinen, J.T., Tingart, M.J., Apreleva, M., Ticker, J.B., Warner, J.P.J., 2004. Variations in glenoid rim anatomy: implications regarding anchor insertion. Arthroscopy 20, 175-178.
-
(2004)
Arthroscopy
, vol.20
, pp. 175-178
-
-
Lehtinen, J.T.1
Tingart, M.J.2
Apreleva, M.3
Ticker, J.B.4
Warner, J.P.J.5
-
15
-
-
3042757174
-
Open procedure for shoulder instability
-
Lembeck, B., Wülker, N., 2004. Open procedure for shoulder instability. Current Orthopaedics 18, 169-180.
-
(2004)
Current Orthopaedics
, vol.18
, pp. 169-180
-
-
Lembeck, B.1
Wülker, N.2
-
16
-
-
0004208567
-
-
fifth ed. Prentice-Hall, Englewood Cliffs, NJ, pp
-
Martini, F.H., Ober, W.C., Garrison, C.W., Welch, K., Hutchings, R.T., 2001. Fundamentals of Anatomy and Physiology, fifth ed. Prentice-Hall, Englewood Cliffs, NJ, pp. 230-233.
-
(2001)
Fundamentals of Anatomy and Physiology
, pp. 230-233
-
-
Martini, F.H.1
Ober, W.C.2
Garrison, C.W.3
Welch, K.4
Hutchings, R.T.5
-
17
-
-
0347634584
-
Glenohumeral translations are increased after a type II superior labrum anterior-posterior lesion: A cadaveric study of severity of passive stabilizer injury
-
McMahon, P.J., Burkart, A., Musahl, V., Debski, R.E., 2004. Glenohumeral translations are increased after a type II superior labrum anterior-posterior lesion: a cadaveric study of severity of passive stabilizer injury. Journal of Shoulder and Elbow Surgery 13, 39-44.
-
(2004)
Journal of Shoulder and Elbow Surgery
, vol.13
, pp. 39-44
-
-
McMahon, P.J.1
Burkart, A.2
Musahl, V.3
Debski, R.E.4
-
18
-
-
0034839613
-
Laser morphometric analysis of the glenoid fossa of the scapula
-
Monk, A.P., Berry, E., Limb, D., Soames, R.W., 2001. Laser morphometric analysis of the glenoid fossa of the scapula. Clinical Anatomy 14, 320-323.
-
(2001)
Clinical Anatomy
, vol.14
, pp. 320-323
-
-
Monk, A.P.1
Berry, E.2
Limb, D.3
Soames, R.W.4
-
19
-
-
0033622802
-
Modeling the stability of the glenohumeral joint during external rotation
-
Novotny, J.E., Beynnon, B.D., Nichols, C.E., 2000. Modeling the stability of the glenohumeral joint during external rotation. Journal of Biomechanics 33, 345-354.
-
(2000)
Journal of Biomechanics
, vol.33
, pp. 345-354
-
-
Novotny, J.E.1
Beynnon, B.D.2
Nichols, C.E.3
-
20
-
-
33947598435
-
Acromial morphology: Effects of suboptimal radiographs
-
Stehle, J., Moore, S.M., Alaseirlis, D.A., Debski, R.E., McMahon, P.J., 2007. Acromial morphology: effects of suboptimal radiographs. Journal of Shoulder and Elbow Surgery 16, 135-142.
-
(2007)
Journal of Shoulder and Elbow Surgery
, vol.16
, pp. 135-142
-
-
Stehle, J.1
Moore, S.M.2
Alaseirlis, D.A.3
Debski, R.E.4
McMahon, P.J.5
-
21
-
-
0037657950
-
Glenoid rim morphology in recurrent anterior glenohumeral instability
-
Sugaya, H., Moriishi, J., Dohi, M., Kon, Y., Tsuchiya, A., 2003. Glenoid rim morphology in recurrent anterior glenohumeral instability. Journal of Bone and Joint Surgery America 85 (A), 878-884.
-
(2003)
Journal of Bone and Joint Surgery America 85 (A)
, pp. 878-884
-
-
Sugaya, H.1
Moriishi, J.2
Dohi, M.3
Kon, Y.4
Tsuchiya, A.5
-
22
-
-
0028439509
-
Analysis of the kinematics and dynamic behavior of the shoulder mechanism
-
Van der Helm, F.C.T., 1994. Analysis of the kinematics and dynamic behavior of the shoulder mechanism. Journal of Biomechanics 27, 527-550.
-
(1994)
Journal of Biomechanics
, vol.27
, pp. 527-550
-
-
Van der Helm, F.C.T.1
-
23
-
-
0001899403
-
A standardized protocol for motion recordings of the shoulder
-
Veeger, H.E.J, Van der Helm, F.C.T, Rozing, P.M, Eds, Maastricht, Netherlands
-
Van der Helm, F.C.T., 1997. A standardized protocol for motion recordings of the shoulder. In: Veeger, H.E.J., Van der Helm, F.C.T., Rozing, P.M. (Eds.), Proceedings of the First Conference of the International Shoulder Group. Maastricht, Netherlands.
-
(1997)
Proceedings of the First Conference of the International Shoulder Group
-
-
Van der Helm, F.C.T.1
-
24
-
-
0029239651
-
Three dimensional recording and description of motions of the shoulder mechanism
-
Van der Helm, F., Pronk, G.M., 1995. Three dimensional recording and description of motions of the shoulder mechanism. Journal of Biomechanical Engineering 117, 27-40.
-
(1995)
Journal of Biomechanical Engineering
, vol.117
, pp. 27-40
-
-
Van der Helm, F.1
Pronk, G.M.2
-
25
-
-
0041560125
-
The effect of glenoid inclination on superior humeral head migration
-
Wong, A.S., Gallo, L., Kuhn, J.E., Carpenter, J.E., Hughes, R.E., 2003. The effect of glenoid inclination on superior humeral head migration. Journal of Shoulder and Elbow Surgery 12, 360-364.
-
(2003)
Journal of Shoulder and Elbow Surgery
, vol.12
, pp. 360-364
-
-
Wong, A.S.1
Gallo, L.2
Kuhn, J.E.3
Carpenter, J.E.4
Hughes, R.E.5
-
26
-
-
20144387878
-
ISB recommendation on the definitions of joint coordinate systems of various joints for the reporting of human joint motion-part II: Shoulder, elbow, wrist and hand
-
Wu, G., van der Helm, F.C.T., Veeger, H.E.J., Makhsous, M., Roy, P.V., Anglin, C., Nagels, J., Karduna, A.R., McQuade, K., Wang, X., Werner, F.W., Buchholz, B., 2005. ISB recommendation on the definitions of joint coordinate systems of various joints for the reporting of human joint motion-part II: shoulder, elbow, wrist and hand. Journal of Biomechanics 38, 981-992.
-
(2005)
Journal of Biomechanics
, vol.38
, pp. 981-992
-
-
Wu, G.1
van der Helm, F.C.T.2
Veeger, H.E.J.3
Makhsous, M.4
Roy, P.V.5
Anglin, C.6
Nagels, J.7
Karduna, A.R.8
McQuade, K.9
Wang, X.10
Werner, F.W.11
Buchholz, B.12
-
27
-
-
41649092525
-
Predicting the shapes of bones at a joint: Application to the shoulder
-
Yang, Y.H.M., Rueckert, D., Bull, A.M.J., 2008. Predicting the shapes of bones at a joint: application to the shoulder. Computer Methods in Biomechanics and Biomedical Engineering 11, 19-30.
-
(2008)
Computer Methods in Biomechanics and Biomedical Engineering
, vol.11
, pp. 19-30
-
-
Yang, Y.H.M.1
Rueckert, D.2
Bull, A.M.J.3
|