메뉴 건너뛰기




Volumn 55, Issue 9, 2008, Pages 1921-1934

Reduction of influence of variation in center frequencies of RF echoes on estimation of artery-wall strain

Author keywords

[No Author keywords available]

Indexed keywords

CHLORINE COMPOUNDS; CORRELATION METHODS; ELASTICITY; ERROR ANALYSIS; ESTIMATION; FREQUENCY ESTIMATION; HEALTH; MOTION ESTIMATION; MUSCLE; NUMERICAL ANALYSIS; SPEECH COMMUNICATION; STANDARDS; WALLS (STRUCTURAL PARTITIONS);

EID: 52649112758     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.884     Document Type: Article
Times cited : (40)

References (49)
  • 1
    • 0025896776 scopus 로고
    • Structure-dependent dynamic mechanical behavior of fibrous caps from human atherosclerotic plaques
    • R. T. Lee, A. J. Grodzinsky, E. H. Frank, R. D. Kamm, and F. J. Schoen, "Structure-dependent dynamic mechanical behavior of fibrous caps from human atherosclerotic plaques," Circulation, vol. 83, no. 5, pp. 1764-1770, 1991.
    • (1991) Circulation , vol.83 , Issue.5 , pp. 1764-1770
    • Lee, R.T.1    Grodzinsky, A.J.2    Frank, E.H.3    Kamm, R.D.4    Schoen, F.J.5
  • 2
    • 0028370884 scopus 로고
    • Static circumferential tangential modulus of human atherosclerotic tissue
    • H. M. Loree, A. J. Grodzinsky, S. Y. Park, L. J. Gibson, and R. T. Lee, "Static circumferential tangential modulus of human atherosclerotic tissue," J. Biomech., vol. 27, no. 2, pp. 195-204, 1994.
    • (1994) J. Biomech , vol.27 , Issue.2 , pp. 195-204
    • Loree, H.M.1    Grodzinsky, A.J.2    Park, S.Y.3    Gibson, L.J.4    Lee, R.T.5
  • 3
    • 0025998231 scopus 로고
    • Calculation of pulse-wave velocity using cross-correlation-effects of reflexes in the arterial tree
    • M. Benthin, P. Dahl, R. Ruzicka, and K. Lindström, "Calculation of pulse-wave velocity using cross-correlation-effects of reflexes in the arterial tree," Ultrasound Med. Biol., vol. 17, no. 5, pp. 461-469, 1991.
    • (1991) Ultrasound Med. Biol , vol.17 , Issue.5 , pp. 461-469
    • Benthin, M.1    Dahl, P.2    Ruzicka, R.3    Lindström, K.4
  • 4
    • 0028391807 scopus 로고
    • New method for evaluating local pulse wave velocity by measuring vibrations on aortic wall
    • H. Kanai, K. Kawabe, M. Takano, R. Murata, N. Chubachi, and Y. Koiwa, "New method for evaluating local pulse wave velocity by measuring vibrations on aortic wall," Electron. Lett., vol. 30, no. 7, pp. 534-536, 1993.
    • (1993) Electron. Lett , vol.30 , Issue.7 , pp. 534-536
    • Kanai, H.1    Kawabe, K.2    Takano, M.3    Murata, R.4    Chubachi, N.5    Koiwa, Y.6
  • 5
    • 0032409973 scopus 로고    scopus 로고
    • A noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound
    • P. J. Brands, J. M. Willigers, L. A. F. Ledoux, R. S. Reneman, and A. P. G. Hoeks, "A noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound," Ultrasound Med. Biol., vol. 24, no. 9, pp. 1325-1335, 1998.
    • (1998) Ultrasound Med. Biol , vol.24 , Issue.9 , pp. 1325-1335
    • Brands, P.J.1    Willigers, J.M.2    Ledoux, L.A.F.3    Reneman, R.S.4    Hoeks, A.P.G.5
  • 6
  • 7
    • 0034971760 scopus 로고    scopus 로고
    • Assessment of the spatial homogeneity of artery dimension parameters with high frame rate 2-D B-mode
    • J. M. Meinders, P. J. Brands, J. M. Willigers, L. Kornet, and A. P. G. Hoeks, "Assessment of the spatial homogeneity of artery dimension parameters with high frame rate 2-D B-mode," Ultrasound Med. Biol., vol. 27, no. 6, pp. 785-794, 2001.
    • (2001) Ultrasound Med. Biol , vol.27 , Issue.6 , pp. 785-794
    • Meinders, J.M.1    Brands, P.J.2    Willigers, J.M.3    Kornet, L.4    Hoeks, A.P.G.5
  • 8
    • 0021959888 scopus 로고
    • Transcutaneous detection of relative changes in artery diameter
    • A. P. G. Hoeks, C. J. Ruissen, P. Hick, and R. S. Reneman, "Transcutaneous detection of relative changes in artery diameter," Ultrasound Med. Biol., vol. 11, no. 1, pp. 51-59, 1985.
    • (1985) Ultrasound Med. Biol , vol.11 , Issue.1 , pp. 51-59
    • Hoeks, A.P.G.1    Ruissen, C.J.2    Hick, P.3    Reneman, R.S.4
  • 10
    • 0029739654 scopus 로고    scopus 로고
    • A noninvasive method to estimate arterial impedance by means of assessment of local diameter change and the local center-line blood flow velocity using ultrasound
    • P. J. Brands, A. P. G. Hoeks, M. C. M. Rutten, and R. S. Reneman, "A noninvasive method to estimate arterial impedance by means of assessment of local diameter change and the local center-line blood flow velocity using ultrasound," Ultrasound Med. Biol., vol. 22, no. 7, pp. 895-905, 1996.
    • (1996) Ultrasound Med. Biol , vol.22 , Issue.7 , pp. 895-905
    • Brands, P.J.1    Hoeks, A.P.G.2    Rutten, M.C.M.3    Reneman, R.S.4
  • 11
    • 0025806883 scopus 로고
    • Elastography: A quantitative method for imaging the elasticity of biological tissues
    • J. Ophir, I. Céspedes, H. Ponnekanti, Y. Yazdi, and X. Li, "Elastography: A quantitative method for imaging the elasticity of biological tissues," Ultrason. Imag., vol. 13, pp. 111-134, 1991.
    • (1991) Ultrason. Imag , vol.13 , pp. 111-134
    • Ophir, J.1    Céspedes, I.2    Ponnekanti, H.3    Yazdi, Y.4    Li, X.5
  • 12
    • 0027177373 scopus 로고
    • Reduction of image noise in elastography
    • I. Céspedes and J. Ophir, "Reduction of image noise in elastography," Ultrason. Imag., vol. 15, pp. 89-102, 1993.
    • (1993) Ultrason. Imag , vol.15 , pp. 89-102
    • Céspedes, I.1    Ophir, J.2
  • 13
    • 0032191886 scopus 로고    scopus 로고
    • A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strain and Poisson's ratios in tissues
    • E. E. Konofagou, J. Ophir, T. Varghese, and F. Kallel, "A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strain and Poisson's ratios in tissues," Ultrasound Med. Biol., vol. 24, no. 8, pp. 1183-1199, 1998.
    • (1998) Ultrasound Med. Biol , vol.24 , Issue.8 , pp. 1183-1199
    • Konofagou, E.E.1    Ophir, J.2    Varghese, T.3    Kallel, F.4
  • 15
    • 0030825419 scopus 로고    scopus 로고
    • Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms
    • C. L. de Korte, E. I. Céspedes, A. F. W. van der Steen, and C. T. Lanée, "Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms," Ultrasound Med. Biol., vol. 23, no. 5, pp. 735-746, 1997.
    • (1997) Ultrasound Med. Biol , vol.23 , Issue.5 , pp. 735-746
    • de Korte, C.L.1    Céspedes, E.I.2    van der Steen, A.F.W.3    Lanée, C.T.4
  • 16
    • 0343729905 scopus 로고    scopus 로고
    • Intraluminal ultrasonic palpation: Assessment of local and cross-sectional tissue stiffness
    • E. I. Céspedes, C. L. de Korte, and A. F. W. van der Steen, "Intraluminal ultrasonic palpation: Assessment of local and cross-sectional tissue stiffness," Ultrasound Med. Biol., vol. 26, no. 3, pp. 385-396, 2000.
    • (2000) Ultrasound Med. Biol , vol.26 , Issue.3 , pp. 385-396
    • Céspedes, E.I.1    de Korte, C.L.2    van der Steen, A.F.W.3
  • 17
    • 0035486254 scopus 로고    scopus 로고
    • Blood flow and tissue motion with ultrasound for vascular applications
    • O. Bonnefous, "Blood flow and tissue motion with ultrasound for vascular applications," C. R. Acad. Sci. Ser. IV Phys., vol. 2, pp. 1161-1178, 2001.
    • (2001) C. R. Acad. Sci. Ser. IV Phys , vol.2 , pp. 1161-1178
    • Bonnefous, O.1
  • 20
    • 3042659013 scopus 로고    scopus 로고
    • Vascular intramural strain imaging using arterial pressure equalization
    • K. Kim, W. F. Weitzel, J. M. Rubin, H. Xie, X. Chen, and M. O'Donnell, "Vascular intramural strain imaging using arterial pressure equalization," Ultrasound Med. Biol., vol. 30, no. 6, pp. 761-771, 2004.
    • (2004) Ultrasound Med. Biol , vol.30 , Issue.6 , pp. 761-771
    • Kim, K.1    Weitzel, W.F.2    Rubin, J.M.3    Xie, H.4    Chen, X.5    O'Donnell, M.6
  • 21
    • 0032785966 scopus 로고    scopus 로고
    • Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation
    • M. A. Lubinski, S. Y. Emelianov, and M. O'Donnell, "Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 46, no. 1, pp. 82-96, 1999.
    • (1999) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.46 , Issue.1 , pp. 82-96
    • Lubinski, M.A.1    Emelianov, S.Y.2    O'Donnell, M.3
  • 22
    • 0035713310 scopus 로고    scopus 로고
    • Axial strain imaging of intravascular data: Results on polyvinyl alcohol cryogel phantoms and carotid artery
    • E. Brusseau, J. Fromageau, G. Finet, P. Delachartre, and D. Vray, "Axial strain imaging of intravascular data: Results on polyvinyl alcohol cryogel phantoms and carotid artery," Ultrasound Med. Biol., vol. 27, no. 12, pp. 1631-1642, 2001.
    • (2001) Ultrasound Med. Biol , vol.27 , Issue.12 , pp. 1631-1642
    • Brusseau, E.1    Fromageau, J.2    Finet, G.3    Delachartre, P.4    Vray, D.5
  • 24
    • 0031075651 scopus 로고    scopus 로고
    • Noninvasive evaluation of Poisson's ratio of arterial wall using ultrasound
    • H. Hasegawa, H. Kanai, Y. Koiwa, and N. Chubachi, "Noninvasive evaluation of Poisson's ratio of arterial wall using ultrasound," Electron. Lett., vol. 33, no. 4, pp. 340-342, 1997.
    • (1997) Electron. Lett , vol.33 , Issue.4 , pp. 340-342
    • Hasegawa, H.1    Kanai, H.2    Koiwa, Y.3    Chubachi, N.4
  • 26
    • 0033276932 scopus 로고    scopus 로고
    • Real-time measurements of local myocardium motion and arterial wall thickening
    • H. Kanai, Y. Koiwa, and J. Zhang, "Real-time measurements of local myocardium motion and arterial wall thickening," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 46, no. 5, pp. 1229-1241, 1999.
    • (1999) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.46 , Issue.5 , pp. 1229-1241
    • Kanai, H.1    Koiwa, Y.2    Zhang, J.3
  • 27
    • 0036578388 scopus 로고    scopus 로고
    • Modified phased tracking method for measurement of change in thickness of arterial wall
    • H. Hasegawa, H. Kanai, and Y. Koiwa, "Modified phased tracking method for measurement of change in thickness of arterial wall," Jpn. J. Appl. Phys., vol. 41, no. 5B, pp. 3563-3571, 2002.
    • (2002) Jpn. J. Appl. Phys , vol.41 , Issue.5 B , pp. 3563-3571
    • Hasegawa, H.1    Kanai, H.2    Koiwa, Y.3
  • 28
    • 21144433117 scopus 로고    scopus 로고
    • Evaluating the regional elastic modulus of a cylindrical shell with nonuniform wall thickness
    • H. Hasegawa, H. Kanai, N. Hoshimiya, and Y. Koiwa, "Evaluating the regional elastic modulus of a cylindrical shell with nonuniform wall thickness," J. Med. Ultrason., vol. 31, no. 2, pp. 81-90, 2004.
    • (2004) J. Med. Ultrason , vol.31 , Issue.2 , pp. 81-90
    • Hasegawa, H.1    Kanai, H.2    Hoshimiya, N.3    Koiwa, Y.4
  • 29
    • 0037662871 scopus 로고    scopus 로고
    • Elasticity imaging of atheroma with transcutaneous ultrasound-preliminary study
    • H. Kanai, H. Hasegawa, M. Ichiki, F. Tezuka, and Y. Koiwa, "Elasticity imaging of atheroma with transcutaneous ultrasound-preliminary study," Circulation, vol. 107, no. 24, pp. 3018-3021, 2003.
    • (2003) Circulation , vol.107 , Issue.24 , pp. 3018-3021
    • Kanai, H.1    Hasegawa, H.2    Ichiki, M.3    Tezuka, F.4    Koiwa, Y.5
  • 30
    • 33744502129 scopus 로고    scopus 로고
    • Construction of reference data for tissue characterization of arterial wall based on elasticity images
    • J. Inagaki, H. Hasegawa, H. Kanai, M. Ichiki, F. Tezuka, and Y. Koiwa, "Construction of reference data for tissue characterization of arterial wall based on elasticity images," Jpn. J. Appl. Phys., vol. 44, no. 6B, pp. 4593-4597, 2005.
    • (2005) Jpn. J. Appl. Phys , vol.44 , Issue.6 B , pp. 4593-4597
    • Inagaki, J.1    Hasegawa, H.2    Kanai, H.3    Ichiki, M.4    Tezuka, F.5    Koiwa, Y.6
  • 31
    • 33744463126 scopus 로고    scopus 로고
    • Tissue classification of arterial wall based on elasticity image
    • J. Inagaki, H. Hasegawa, H. Kanai, M. Ichiki, F. Tezuka, and Y. Koiwa, "Tissue classification of arterial wall based on elasticity image," Jpn. J. Appl. Phys., vol. 45, no. 5B, pp. 4732-4735, 2006.
    • (2006) Jpn. J. Appl. Phys , vol.45 , Issue.5 B , pp. 4732-4735
    • Inagaki, J.1    Hasegawa, H.2    Kanai, H.3    Ichiki, M.4    Tezuka, F.5    Koiwa, Y.6
  • 32
    • 84939739865 scopus 로고
    • Real-time two-dimensional blood flow imaging using an autocorrelation technique
    • C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, "Real-time two-dimensional blood flow imaging using an autocorrelation technique," IEEE Trans. Sonics Ultrason., vol. SU-32, no. 3, pp. 458-464, 1985.
    • (1985) IEEE Trans. Sonics Ultrason , vol.SU-32 , Issue.3 , pp. 458-464
    • Kasai, C.1    Namekawa, K.2    Koyano, A.3    Omoto, R.4
  • 33
    • 0032820432 scopus 로고    scopus 로고
    • Power spectral strain estimators in elastography
    • E. E. Konofagou, T. Varghese, J. Ophir, and S. K. Alam, "Power spectral strain estimators in elastography," Ultrasound Med. Biol., vol. 25, no. 7, pp. 1115-1129, 1999.
    • (1999) Ultrasound Med. Biol , vol.25 , Issue.7 , pp. 1115-1129
    • Konofagou, E.E.1    Varghese, T.2    Ophir, J.3    Alam, S.K.4
  • 34
    • 0034150122 scopus 로고    scopus 로고
    • Spectral estimators in elastography
    • E. E. Konofagou, T. Varghese, and J. Ophir, "Spectral estimators in elastography," Ultrasonics, vol. 38, pp. 412-416, 2000.
    • (2000) Ultrasonics , vol.38 , pp. 412-416
    • Konofagou, E.E.1    Varghese, T.2    Ophir, J.3
  • 35
    • 0021411029 scopus 로고
    • Comparison of the deskewed short-time correlator and the maximum likelihood correlator
    • J. W. Betz, "Comparison of the deskewed short-time correlator and the maximum likelihood correlator," IEEE Trans. Acoust. Speech Signal Process., vol. ASSP-32, no. 2, pp. 285-294, 1984.
    • (1984) IEEE Trans. Acoust. Speech Signal Process , vol.ASSP-32 , Issue.2 , pp. 285-294
    • Betz, J.W.1
  • 36
    • 0019727330 scopus 로고
    • Estimation of location and motion parameters of a moving source observed from a linear array
    • J. C. Hassab, B. W. Guimond, and S. C. Nardone, "Estimation of location and motion parameters of a moving source observed from a linear array," J. Acoust. Soc. Am., vol. 70, no. 4, pp. 1054-1061, 1981.
    • (1981) J. Acoust. Soc. Am , vol.70 , Issue.4 , pp. 1054-1061
    • Hassab, J.C.1    Guimond, B.W.2    Nardone, S.C.3
  • 37
    • 0019009621 scopus 로고
    • Correlation compensation requirements for passive time delay estimation with moving source or receivers
    • W. B. Adams, J. P. Kuhn, and W. P. Whyland, "Correlation compensation requirements for passive time delay estimation with moving source or receivers," IEEE Trans. Acoust. Speech Signal Process., vol. ASSP-28, no. 2, pp. 158-168, 1980.
    • (1980) IEEE Trans. Acoust. Speech Signal Process , vol.ASSP-28 , Issue.2 , pp. 158-168
    • Adams, W.B.1    Kuhn, J.P.2    Whyland, W.P.3
  • 38
    • 0029980462 scopus 로고    scopus 로고
    • Deformation models and correlation analysis in elastography
    • M. Bilgen and M. F. Insana, "Deformation models and correlation analysis in elastography," J. Acoust. Soc. Am., vol. 99, no. 5, pp. 3212-3224, 1996.
    • (1996) J. Acoust. Soc. Am , vol.99 , Issue.5 , pp. 3212-3224
    • Bilgen, M.1    Insana, M.F.2
  • 39
    • 0030459735 scopus 로고    scopus 로고
    • Performance optimization in elastography: Multicompression with temporal stretching
    • T. Varghese and J. Ophir, "Performance optimization in elastography: Multicompression with temporal stretching," Ultrason. Imag., vol. 18, pp. 193-214, 1996.
    • (1996) Ultrason. Imag , vol.18 , pp. 193-214
    • Varghese, T.1    Ophir, J.2
  • 40
    • 0031056017 scopus 로고    scopus 로고
    • Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography
    • S. K. Alam and J. Ophir, "Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography," Ultrasound Med. Biol., vol. 23, no. 2, pp. 95-105, 1997.
    • (1997) Ultrasound Med. Biol , vol.23 , Issue.2 , pp. 95-105
    • Alam, S.K.1    Ophir, J.2
  • 41
    • 0030736520 scopus 로고    scopus 로고
    • Enhancement of echo-signal correlation in elastography using temporal stretching
    • T. Varghese and J. Ophir, "Enhancement of echo-signal correlation in elastography using temporal stretching," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 44, no. 1, pp. 173-180, 1997.
    • (1997) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.44 , Issue.1 , pp. 173-180
    • Varghese, T.1    Ophir, J.2
  • 43
    • 0029344834 scopus 로고
    • An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approach
    • T. Loupas, J. T. Powers, and R. W. Gill, "An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approach," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 42, no. 4, pp. 672-688, 1995.
    • (1995) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.42 , Issue.4 , pp. 672-688
    • Loupas, T.1    Powers, J.T.2    Gill, R.W.3
  • 44
    • 0036277861 scopus 로고    scopus 로고
    • Ultrasound-based vessel wall tracking: An auto-correlation technique with RF center frequency estimation
    • S. I. Rabben, S. Bjærum, V. Sørhus, and H. Torp, "Ultrasound-based vessel wall tracking: An auto-correlation technique with RF center frequency estimation," Ultrasound Med. Biol., vol. 28, no. 4, pp. 507-517, 2002.
    • (2002) Ultrasound Med. Biol , vol.28 , Issue.4 , pp. 507-517
    • Rabben, S.I.1    Bjærum, S.2    Sørhus, V.3    Torp, H.4
  • 45
    • 33846199889 scopus 로고    scopus 로고
    • Modification of the phased-tracking method for reduction of artifacts in estimated artery wall deformation
    • H. Hasegawa and H. Kanai, "Modification of the phased-tracking method for reduction of artifacts in estimated artery wall deformation," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 11, pp. 2050-2064, 2006.
    • (2006) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.53 , Issue.11 , pp. 2050-2064
    • Hasegawa, H.1    Kanai, H.2
  • 47
    • 32044472533 scopus 로고    scopus 로고
    • Young's modulus reconstruction of vulnerable atherosclerotic plaque components using deformable curves
    • R. A. Baldewsing, F. Mastik, J. A. Schaar, P. W. Serruys, and A. F. W. van der Steen, "Young's modulus reconstruction of vulnerable atherosclerotic plaque components using deformable curves," Ultrasound Med. Biol., vol. 32, no. 2, pp. 201-210, 2006.
    • (2006) Ultrasound Med. Biol , vol.32 , Issue.2 , pp. 201-210
    • Baldewsing, R.A.1    Mastik, F.2    Schaar, J.A.3    Serruys, P.W.4    van der Steen, A.F.W.5
  • 48
    • 17444371294 scopus 로고    scopus 로고
    • Assessment of vulnerable plaque composition by matching the deformation of a parametric plaque model to measured plaque deformation
    • R. A. Baldewsing, J. A. Shaar, F. Mastik, C. W. J. Oomens, and A. F. W. van der Steen, "Assessment of vulnerable plaque composition by matching the deformation of a parametric plaque model to measured plaque deformation," IEEE Trans. Med. Imaging, vol. 24, no. 4, pp. 514-528, 2005.
    • (2005) IEEE Trans. Med. Imaging , vol.24 , Issue.4 , pp. 514-528
    • Baldewsing, R.A.1    Shaar, J.A.2    Mastik, F.3    Oomens, C.W.J.4    van der Steen, A.F.W.5
  • 49
    • 3042519588 scopus 로고    scopus 로고
    • A finite element model for performing intra-vascular ultrasound elastography of human atherosclerotic coronary arteries
    • R. A. Baldewsing, C. L. de Korte, J. A. Shaar, F. Mastik, and A. F. W. van der Steen, "A finite element model for performing intra-vascular ultrasound elastography of human atherosclerotic coronary arteries," Ultrasound Med. Biol., vol. 30, no. 6, pp. 803-813, 2004.
    • (2004) Ultrasound Med. Biol , vol.30 , Issue.6 , pp. 803-813
    • Baldewsing, R.A.1    de Korte, C.L.2    Shaar, J.A.3    Mastik, F.4    van der Steen, A.F.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.