메뉴 건너뛰기




Volumn 16, Issue 4, 2008, Pages 331-334

The utility of microvascular anastomotic devices in head and neck reconstruction

Author keywords

Anastomosis; Microvascular; Reconstruction

Indexed keywords

ARTERY ANASTOMOSIS; BLOOD VESSEL SHUNT; CLIP; COLD ISCHEMIA; HEAD AND NECK SURGERY; HOSPITAL COST; MEDICAL PRACTICE; MICROVASCULAR SURGERY; NONHUMAN; PRIORITY JOURNAL; REVIEW; SURGEON; SURGICAL EQUIPMENT; VEIN ANASTOMOSIS; ANASTOMOSIS; ANIMAL; ARTERY; EQUIPMENT DESIGN; EVIDENCE BASED MEDICINE; GRAFT SURVIVAL; HEAD AND NECK TUMOR; HUMAN; INSTRUMENTATION; MICROSURGERY; PHYSIOLOGY; PLASTIC SURGERY; SUTURING METHOD; VASCULARIZATION; VEIN; WOUND HEALING;

EID: 52449110072     PISSN: 10689508     EISSN: None     Source Type: Journal    
DOI: 10.1097/MOO.0b013e32830139a7     Document Type: Review
Times cited : (18)

References (18)
  • 1
    • 0000222491 scopus 로고
    • Microsurgery in anastomosis of small vessels
    • Jacobson JI, Suarez EL. Microsurgery in anastomosis of small vessels. Surg Forum 1960; 11:243-245.
    • (1960) Surg Forum , vol.11 , pp. 243-245
    • Jacobson, J.I.1    Suarez, E.L.2
  • 2
    • 0024561653 scopus 로고
    • Strength of microvascular anastomoses: Comparison between the UNILINK anastomotic system and sutures
    • Gilbert RW, Ragnarsson R, Berggren A, et al. Strength of microvascular anastomoses: comparison between the UNILINK anastomotic system and sutures. Microsurgery 1989; 10:40-46.
    • (1989) Microsurgery , vol.10 , pp. 40-46
    • Gilbert, R.W.1    Ragnarsson, R.2    Berggren, A.3
  • 3
    • 0024520578 scopus 로고
    • A microvascular anastomotic device, I: A hemodynamic evaluation in rabbit femoral arteries and veins
    • Blair WF, Steyers CM, Brown TD, Gable RH. A microvascular anastomotic device, I: a hemodynamic evaluation in rabbit femoral arteries and veins. Microsurgery 1989; 10:21-28.
    • (1989) Microsurgery , vol.10 , pp. 21-28
    • Blair, W.F.1    Steyers, C.M.2    Brown, T.D.3    Gable, R.H.4
  • 4
    • 0024520579 scopus 로고    scopus 로고
    • Blair WF, Morecraft RJ, Steyers CM, Maynard JA. A microvascular anastomotic device, II:ahistologic studyinarteriesandveins.Microsurgery 1989;10:29-39.
    • Blair WF, Morecraft RJ, Steyers CM, Maynard JA. A microvascular anastomotic device, II:ahistologic studyinarteriesandveins.Microsurgery 1989;10:29-39.
  • 5
    • 0041971040 scopus 로고    scopus 로고
    • Management of significant venous discrepancy with microvascular venous coupler
    • Sullivan SK, Dellacroce F, Allen R. Management of significant venous discrepancy with microvascular venous coupler. J Reconstr Microsurg 2003; 19:377-380.
    • (2003) J Reconstr Microsurg , vol.19 , pp. 377-380
    • Sullivan, S.K.1    Dellacroce, F.2    Allen, R.3
  • 6
    • 33751314744 scopus 로고    scopus 로고
    • Venous thrombosis in coupled versus sutured microvascular anastomoses
    • Yap LH, Constantinides J, Butler CE. Venous thrombosis in coupled versus sutured microvascular anastomoses. Ann Plast Surg 2006; 57:666-669.
    • (2006) Ann Plast Surg , vol.57 , pp. 666-669
    • Yap, L.H.1    Constantinides, J.2    Butler, C.E.3
  • 7
    • 0000399368 scopus 로고
    • A simple new apparatus for small vessel anastomosisi (free autograft of the sigmoid included)
    • Nakayama K, Tamiya T, Yamamoto K, Akimoto S. A simple new apparatus for small vessel anastomosisi (free autograft of the sigmoid included). Surgery 1962; 52:918-931.
    • (1962) Surgery , vol.52 , pp. 918-931
    • Nakayama, K.1    Tamiya, T.2    Yamamoto, K.3    Akimoto, S.4
  • 8
    • 0022830388 scopus 로고
    • The UNILINK instrument system for fast and safe microvascular anastomoses
    • Östrup LT, Berggren A. The UNILINK instrument system for fast and safe microvascular anastomoses. Ann Plast Surg 1986; 17:521-525.
    • (1986) Ann Plast Surg , vol.17 , pp. 521-525
    • Östrup, L.T.1    Berggren, A.2
  • 9
    • 0028303128 scopus 로고
    • Clinical experience with the 3M micro-vascular coupling anastomotic device in 100 free-tissue transfers
    • Ahn CY, Shaw WW, Berns S, et al. Clinical experience with the 3M micro-vascular coupling anastomotic device in 100 free-tissue transfers. Plast Reconstr Surg 1994; 93:1481-1484.
    • (1994) Plast Reconstr Surg , vol.93 , pp. 1481-1484
    • Ahn, C.Y.1    Shaw, W.W.2    Berns, S.3
  • 10
    • 67650012133 scopus 로고    scopus 로고
    • Cope C, Ng RLH, Miller M, et al. Technique and clinical experience of the Unilink/3M® microvascular anastomotic coupling device in free flap surgery. Internet J Plast Surg 2001; 1:1.
    • Cope C, Ng RLH, Miller M, et al. Technique and clinical experience of the Unilink/3M® microvascular anastomotic coupling device in free flap surgery. Internet J Plast Surg 2001; 1:1.
  • 11
    • 26844454157 scopus 로고    scopus 로고
    • Arterial coupling for microvascular free tissue transfer in head and neck reconstruction
    • Ross DA, Chow JY, Shin J, et al. Arterial coupling for microvascular free tissue transfer in head and neck reconstruction. Arch Otolaryngol Head Neck Surg 2005; 131:891-895.
    • (2005) Arch Otolaryngol Head Neck Surg , vol.131 , pp. 891-895
    • Ross, D.A.1    Chow, J.Y.2    Shin, J.3
  • 12
    • 0029992050 scopus 로고    scopus 로고
    • Use of a mechanical microvascular anastomotic device in head and neck free tissue transfer
    • Shindo ML, Costantino PD, Nalbone VP, et al. Use of a mechanical microvascular anastomotic device in head and neck free tissue transfer. Arch Otolaryngol Head Neck Surg 1996; 122:529-532.
    • (1996) Arch Otolaryngol Head Neck Surg , vol.122 , pp. 529-532
    • Shindo, M.L.1    Costantino, P.D.2    Nalbone, V.P.3
  • 13
    • 0036225485 scopus 로고    scopus 로고
    • Clinical experience with non-penetrating vascular clips in free-flap reconstructions
    • Zeebregts C, Acosta R, Bolander L, et al. Clinical experience with non-penetrating vascular clips in free-flap reconstructions. Br J Plast Surg 2002; 55:105-110.
    • (2002) Br J Plast Surg , vol.55 , pp. 105-110
    • Zeebregts, C.1    Acosta, R.2    Bolander, L.3
  • 16
    • 0028142199 scopus 로고
    • Clinical use ofthe3M2.5mm mechanical microcoupling device in free tissue transfer
    • SassonHN, Stofman GM,BermanP.Clinical use ofthe3M2.5mm mechanical microcoupling device in free tissue transfer. Microsurgery 1994; 15:421-423.
    • (1994) Microsurgery , vol.15 , pp. 421-423
    • Sasson, H.N.1    Stofman, G.M.2    Berman, P.3
  • 17
    • 0028839589 scopus 로고
    • Clinical experience with a microvascular anastomotic deviceinhead and neck reconstruction.AmJ
    • DeLacure MD, Wong RS, Markowitz BL, et al. Clinical experience with a microvascular anastomotic deviceinhead and neck reconstruction.AmJ Surg 1995; 170:521-523.
    • (1995) Surg , vol.170 , pp. 521-523
    • DeLacure, M.D.1    Wong, R.S.2    Markowitz, B.L.3
  • 18
    • 0033919383 scopus 로고    scopus 로고
    • Use of the vascular closure staple clip applier for microvascular anastomosis in free-flap surgery
    • Cope C, Lee K, Stern H, Pennington D. Use of the vascular closure staple clip applier for microvascular anastomosis in free-flap surgery. Plast Reconstr Surg 2000; 106:107-110.
    • (2000) Plast Reconstr Surg , vol.106 , pp. 107-110
    • Cope, C.1    Lee, K.2    Stern, H.3    Pennington, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.