1
-
-
50349105056
-
Automatic electroencephalographic control of general anesthesia
-
R. G. Bickford, "Automatic electroencephalographic control of general anesthesia," Electroencephalographic Clin. Neurophysiol., vol. 2, pp. 93-96, 1950.
-
(1950)
Electroencephalographic Clin. Neurophysiol
, vol.2
, pp. 93-96
-
-
Bickford, R.G.1
-
2
-
-
0023180697
-
Quantitative EEG analysis during anesthesia with isoflurane in nitrous oxide at 1.3 and 1.5 MAC
-
H. Schwilden and H. Stoeckel, "Quantitative EEG analysis during anesthesia with isoflurane in nitrous oxide at 1.3 and 1.5 MAC," Brit. J. Anaesth., vol. 59, pp. 738-745, 1987.
-
(1987)
Brit. J. Anaesth
, vol.59
, pp. 738-745
-
-
Schwilden, H.1
Stoeckel, H.2
-
3
-
-
0030901893
-
Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in normal volunteers
-
P. S. Glass, M. Bloom, L. Kearse, C. Rosow, P. Sebel, and P. Manberg, "Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in normal volunteers," Anesthesiology, vol. 86, pp. 836-847, 1997.
-
(1997)
Anesthesiology
, vol.86
, pp. 836-847
-
-
Glass, P.S.1
Bloom, M.2
Kearse, L.3
Rosow, C.4
Sebel, P.5
Manberg, P.6
-
4
-
-
79956012333
-
BIS EEG monitoring: What it can and cannot do in regard to unintentional awareness
-
G. Plourde, "BIS EEG monitoring: What it can and cannot do in regard to unintentional awareness," Can. J. Anesth., vol. 49, p. R12, 2002.
-
(2002)
Can. J. Anesth
, vol.49
-
-
Plourde, G.1
-
5
-
-
0033756899
-
Development and clinical application of electroencephalographic bispectrum monitoring
-
J. W. Johansen and P. S. Sebel, "Development and clinical application of electroencephalographic bispectrum monitoring," Anesthesiology, vol. 93, pp. 1336-1340, 2000.
-
(2000)
Anesthesiology
, vol.93
, pp. 1336-1340
-
-
Johansen, J.W.1
Sebel, P.S.2
-
6
-
-
0038343448
-
Adaptive control for nonnegative and compartmental dynamical systems with applications to general anesthesia
-
W. M. Haddad, T. Hayakawa, and J. M. Bailey, "Adaptive control for nonnegative and compartmental dynamical systems with applications to general anesthesia," Int. J. Adapt. Control Signal Process., vol. 17, pp. 209-235, 2003.
-
(2003)
Int. J. Adapt. Control Signal Process
, vol.17
, pp. 209-235
-
-
Haddad, W.M.1
Hayakawa, T.2
Bailey, J.M.3
-
7
-
-
28444469166
-
Adaptive control for nonlinear compartmental dynamical systems with applications to clinical pharmacology
-
_, "Adaptive control for nonlinear compartmental dynamical systems with applications to clinical pharmacology," Sys. Contr. Lett., vol. 55, pp. 62-70, 2006.
-
(2006)
Sys. Contr. Lett
, vol.55
, pp. 62-70
-
-
Haddad, W.M.1
Hayakawa, T.2
Bailey, J.M.3
-
8
-
-
34547092430
-
Neural network adaptive output feedback control for intensive care unit sedation and intraoperative anesthesia
-
W. M. Haddad, J. M. Bailey, T. Hayakawa, and N. Hovakimyan, "Neural network adaptive output feedback control for intensive care unit sedation and intraoperative anesthesia," IEEE Trans. Neural Networks, vol. 18, pp. 1049-1066, 2007.
-
(2007)
IEEE Trans. Neural Networks
, vol.18
, pp. 1049-1066
-
-
Haddad, W.M.1
Bailey, J.M.2
Hayakawa, T.3
Hovakimyan, N.4
-
9
-
-
34047200859
-
Adaptive and neural network adaptive control of depth of anesthesia during surgery
-
Minneapolis, MN
-
J. Bailey, W. Haddad, J. Im, T. Hayakawa, and P. Nagel, "Adaptive and neural network adaptive control of depth of anesthesia during surgery," in Proc. Amer. Contr. Conf., Minneapolis, MN, 2006, pp. 3409-3414.
-
(2006)
Proc. Amer. Contr. Conf
, pp. 3409-3414
-
-
Bailey, J.1
Haddad, W.2
Im, J.3
Hayakawa, T.4
Nagel, P.5
-
10
-
-
0141638578
-
Upper bounds for approximation of continuous-time dynamics using delayed outputs and feedforward neural networks
-
E. Lavretsky, N. Hovakimyan, and A. J. Calise, "Upper bounds for approximation of continuous-time dynamics using delayed outputs and feedforward neural networks," IEEE Trans. Autom. Control, vol. 48, pp. 1606-1610, 2003.
-
(2003)
IEEE Trans. Autom. Control
, vol.48
, pp. 1606-1610
-
-
Lavretsky, E.1
Hovakimyan, N.2
Calise, A.J.3
-
11
-
-
0032845350
-
Cardiac output is a determinant of the initial concentration of propofol after short-term administration
-
R. N. Upton, G. I. Ludrook, C. Grant, and A. Martinez, "Cardiac output is a determinant of the initial concentration of propofol after short-term administration," Aneth. Analg., vol. 89, pp. 545-552, 1999.
-
(1999)
Aneth. Analg
, vol.89
, pp. 545-552
-
-
Upton, R.N.1
Ludrook, G.I.2
Grant, C.3
Martinez, A.4
-
12
-
-
0026612586
-
Venodilation contributes to propofol-mediated hypotension in humans
-
M. Muzi, R. A. Berens, J. P. Kampine, and T. J. Ebert, "Venodilation contributes to propofol-mediated hypotension in humans," Aneth. Analg., vol. 74, pp. 877-883, 1992.
-
(1992)
Aneth. Analg
, vol.74
, pp. 877-883
-
-
Muzi, M.1
Berens, R.A.2
Kampine, J.P.3
Ebert, T.J.4
-
13
-
-
0026453467
-
Direct effects of propofol on myocardial contractility in situ canine hearts
-
E. F. Ismail, S. J. Kim, and M. R. Salem, "Direct effects of propofol on myocardial contractility in situ canine hearts," Anesthesiology, vol. 79, pp. 964-972, 1992.
-
(1992)
Anesthesiology
, vol.79
, pp. 964-972
-
-
Ismail, E.F.1
Kim, S.J.2
Salem, M.R.3
|