메뉴 건너뛰기




Volumn 22, Issue 6, 2008, Pages 399-403

Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: A cadaveric model

Author keywords

Fracture biomechanics; Locking plates; Proximal tibia fractures

Indexed keywords

ADULT; AGED; ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CADAVER; CLINICAL ARTICLE; EMERGENCY HEALTH SERVICE; EXPERIMENTAL MODEL; FEMALE; FRACTURE FIXATION; GROUPS BY AGE; HUMAN; INTERMETHOD COMPARISON; MALE; MATERIALS TESTING; OSTEOTOMY; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROXIMAL TIBIA FRACTURE; RIGIDITY; ELASTICITY; EQUIPMENT; INSTRUMENTATION; INTERNAL FIXATOR; METHODOLOGY; OSTEOSYNTHESIS; TIBIA; TIBIA FRACTURE; WEIGHT BEARING;

EID: 52449087541     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e318178417e     Document Type: Article
Times cited : (55)

References (26)
  • 1
    • 0028349299 scopus 로고
    • Combined anterior and posterior approaches for complex tibial plateau fractures
    • Georgiadis GM. Combined anterior and posterior approaches for complex tibial plateau fractures. J Bone Joint Surg Br. 1994;76:285-289.
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 285-289
    • Georgiadis, G.M.1
  • 2
    • 33746923045 scopus 로고    scopus 로고
    • Functional outcomes of severe bicondylar tibial plateau fractures treated with dual incisions and medial and lateral plates
    • Barei DP, Nork SE, Mills WJ, et al. Functional outcomes of severe bicondylar tibial plateau fractures treated with dual incisions and medial and lateral plates. J Bone Joint Surg Am. 2006;88:1713-1721.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 1713-1721
    • Barei, D.P.1    Nork, S.E.2    Mills, W.J.3
  • 3
    • 16644381922 scopus 로고    scopus 로고
    • Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique
    • Barei DP, Nork SE, Mills WJ, et al. Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Ortho Trauma. 2004;18:649-657.
    • (2004) J Ortho Trauma , vol.18 , pp. 649-657
    • Barei, D.P.1    Nork, S.E.2    Mills, W.J.3
  • 4
    • 33847126604 scopus 로고    scopus 로고
    • Complications of locking plate fixation in complex proximal tibia injuries
    • Phisitkul P, McKinely TO, Nepola JV, et al. Complications of locking plate fixation in complex proximal tibia injuries. J Orthop Trauma. 2007;21:83-91.
    • (2007) J Orthop Trauma , vol.21 , pp. 83-91
    • Phisitkul, P.1    McKinely, T.O.2    Nepola, J.V.3
  • 5
    • 0029821323 scopus 로고    scopus 로고
    • Treatment of high-energy tibial plateau fractures by the ilizarov circular fixator
    • Dendrinos GK, Kontos S, Katsenis D, et al. Treatment of high-energy tibial plateau fractures by the ilizarov circular fixator. J Bone Joint Surg Br. 1996;78:710-717.
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 710-717
    • Dendrinos, G.K.1    Kontos, S.2    Katsenis, D.3
  • 6
    • 24644478526 scopus 로고    scopus 로고
    • Staged management of high-energy proximal tibia fractures (OTA types 41): The results of a prospective, standardized, protocol
    • Egol KA, Tejwani NC, Capla EL, et al. Staged management of high-energy proximal tibia fractures (OTA types 41): The results of a prospective, standardized, protocol. J Orthop Trauma. 2005;19:448-455.
    • (2005) J Orthop Trauma , vol.19 , pp. 448-455
    • Egol, K.A.1    Tejwani, N.C.2    Capla, E.L.3
  • 7
    • 4444358605 scopus 로고    scopus 로고
    • Treatment of complex tibial plateau fractures using the less invasive stabilization system plate. Clinical experience and laboratory comparison with double plates
    • Egol KA, Su E, Tejwani NC, et al. Treatment of complex tibial plateau fractures using the less invasive stabilization system plate. Clinical experience and laboratory comparison with double plates. J Trauma 2004; 57:340-346.
    • (2004) J Trauma , vol.57 , pp. 340-346
    • Egol, K.A.1    Su, E.2    Tejwani, N.C.3
  • 8
    • 0029017383 scopus 로고
    • External fixation and limited internal fixation for complex fractures of the tibia plateau
    • Marsh JL, Smith ST, Do TT. External fixation and limited internal fixation for complex fractures of the tibia plateau. J Bone Joint Surg Am. 1995; 775:661-673.
    • (1995) J Bone Joint Surg Am , vol.775 , pp. 661-673
    • Marsh, J.L.1    Smith, S.T.2    Do, T.T.3
  • 9
    • 0028033031 scopus 로고
    • High-energy fractures of the tibial plateau
    • Watson JT. High-energy fractures of the tibial plateau. Orthop Clin North Am. 1994;25:723-752.
    • (1994) Orthop Clin North Am , vol.25 , pp. 723-752
    • Watson, J.T.1
  • 10
    • 0036093844 scopus 로고    scopus 로고
    • Failure of fixation of tibial plateau fractures
    • Ali AM, El-Shafie M, Willett KM. Failure of fixation of tibial plateau fractures. J Ortho Trauma. 2002;16:323-329.
    • (2002) J Ortho Trauma , vol.16 , pp. 323-329
    • Ali, A.M.1    El-Shafie, M.2    Willett, K.M.3
  • 11
    • 33745572296 scopus 로고    scopus 로고
    • Double plating of unstable proximal tibial fractures using minimally invasive percutaneous osteosynthesis technique
    • Oh CW, Oh JK, Kyung HS, et al. Double plating of unstable proximal tibial fractures using minimally invasive percutaneous osteosynthesis technique. Acta Ortho. 2006;77:524-530.
    • (2006) Acta Ortho , vol.77 , pp. 524-530
    • Oh, C.W.1    Oh, J.K.2    Kyung, H.S.3
  • 12
    • 27844486934 scopus 로고    scopus 로고
    • Percutaneous plate stabilization of proximal tibial fractures
    • Oh JK, Oh CW, Jeon IH, et al. Percutaneous plate stabilization of proximal tibial fractures. J Trauma. 2005;59:431-437.
    • (2005) J Trauma , vol.59 , pp. 431-437
    • Oh, J.K.1    Oh, C.W.2    Jeon, I.H.3
  • 13
    • 4644371690 scopus 로고    scopus 로고
    • Treatment of proximal tibia fractures using the less invasive stabilization system: Surgical experience and early clinical results in 77 fractures
    • Cole PA, Zlowodzki M, Kregor PJ. Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures. J Orthop Trauma. 2004;18:528-535.
    • (2004) J Orthop Trauma , vol.18 , pp. 528-535
    • Cole, P.A.1    Zlowodzki, M.2    Kregor, P.J.3
  • 14
    • 4644335118 scopus 로고    scopus 로고
    • Treatment of complex proximal tibia fractures with the less invasive stabilization system
    • Ricci WM, Rudzki JR, Borrelli J Jr. Treatment of complex proximal tibia fractures with the less invasive stabilization system. J Orthop Trauma. 2004;18:521-527.
    • (2004) J Orthop Trauma , vol.18 , pp. 521-527
    • Ricci, W.M.1    Rudzki, J.R.2    Borrelli Jr., J.3
  • 15
    • 4644231085 scopus 로고    scopus 로고
    • The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: Short term results
    • Stannard JP, Wilson TC, Volgas DA, et al. The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: short term results. J Orthop Trauma. 2004;18:552-558.
    • (2004) J Orthop Trauma , vol.18 , pp. 552-558
    • Stannard, J.P.1    Wilson, T.C.2    Volgas, D.A.3
  • 16
    • 33845447251 scopus 로고    scopus 로고
    • Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Results of a multicenter, prospective, randomized clinical trial
    • Canadian Orthopaedic Trauma Society
    • Canadian Orthopaedic Trauma Society. Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Results of a multicenter, prospective, randomized clinical trial. J Bone Joint Surg Am. 2006;88:2613-2623.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 2613-2623
  • 17
    • 26244447552 scopus 로고    scopus 로고
    • Single lateral locked screw plating of bicondylar tibial plateau fractures
    • Gosling T, Schandlemaier P, Muller M, et al. Single lateral locked screw plating of bicondylar tibial plateau fractures. Clin Orthop Relat Res. 2005; 439:207-214.
    • (2005) Clin Orthop Relat Res , vol.439 , pp. 207-214
    • Gosling, T.1    Schandlemaier, P.2    Muller, M.3
  • 18
    • 67650057975 scopus 로고    scopus 로고
    • Synthes USA. Less Invasive Stabilization System (LISS) Technique Guide. Proximal Tibia. Paoli, PA: Synthes USA; 2000.
    • Synthes USA. Less Invasive Stabilization System (LISS) Technique Guide. Proximal Tibia. Paoli, PA: Synthes USA; 2000.
  • 19
    • 4644329173 scopus 로고    scopus 로고
    • Less invasive stabilization of complex tibial plateau fractures: A biomechanical evaluation of a unilateral locked screw plate and double plating
    • Gosling T, Schandelmaier P, Marti A, et al. Less invasive stabilization of complex tibial plateau fractures: a biomechanical evaluation of a unilateral locked screw plate and double plating. J Orthop Trauma. 2004;18: 546-551.
    • (2004) J Orthop Trauma , vol.18 , pp. 546-551
    • Gosling, T.1    Schandelmaier, P.2    Marti, A.3
  • 20
    • 15044357609 scopus 로고    scopus 로고
    • Primary stability of various forms of osteosynthesis in the treatment of fractures of the proximal tibia
    • Mueller CA, Eingartner C, Schreitmueller E, et al. Primary stability of various forms of osteosynthesis in the treatment of fractures of the proximal tibia. J Bone Joint Surg Br. 2005;87:426-432.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 426-432
    • Mueller, C.A.1    Eingartner, C.2    Schreitmueller, E.3
  • 21
    • 4644233694 scopus 로고    scopus 로고
    • Locking compression plate loosening and plate breakage: A report of four cases
    • Sommer C, Babst R, Muller K, et al. Locking compression plate loosening and plate breakage: a report of four cases. J Ortho Trauma. 2004;18: 571-577.
    • (2004) J Ortho Trauma , vol.18 , pp. 571-577
    • Sommer, C.1    Babst, R.2    Muller, K.3
  • 22
    • 4644278172 scopus 로고    scopus 로고
    • Unstable proximal extraarticular tibia fractures
    • Peindl RD, Zura RD, Vincent A, et al. Unstable proximal extraarticular tibia fractures. J Ortho Trauma. 2004;18:540-545.
    • (2004) J Ortho Trauma , vol.18 , pp. 540-545
    • Peindl, R.D.1    Zura, R.D.2    Vincent, A.3
  • 23
    • 4644222787 scopus 로고    scopus 로고
    • Biomechanics of locked plates and screws
    • Egol KA, Kubiak EN, Fulkerson E, et al. Biomechanics of locked plates and screws. J Ortho Trauma. 2004;18:488-493.
    • (2004) J Ortho Trauma , vol.18 , pp. 488-493
    • Egol, K.A.1    Kubiak, E.N.2    Fulkerson, E.3
  • 24
    • 0141758387 scopus 로고    scopus 로고
    • The strength of different fixation techniques for bicondylar tibial plateau fractures - a biomechanical study
    • Ali AM, Saleh M, Bolongaro S, et al. The strength of different fixation techniques for bicondylar tibial plateau fractures - a biomechanical study. Clin Biomech (Bristol, Avon). 2003;18:864-870.
    • (2003) Clin Biomech (Bristol, Avon) , vol.18 , pp. 864-870
    • Ali, A.M.1    Saleh, M.2    Bolongaro, S.3
  • 25
    • 0033219290 scopus 로고    scopus 로고
    • A biomechanical analysis of internal fixation of complex tibial plateau fractures
    • Horwitz DS, Bachus KN, Craig MA, et al. A biomechanical analysis of internal fixation of complex tibial plateau fractures. J Ortho Trauma. 1999;13:545-549.
    • (1999) J Ortho Trauma , vol.13 , pp. 545-549
    • Horwitz, D.S.1    Bachus, K.N.2    Craig, M.A.3
  • 26
    • 0004038972 scopus 로고
    • test method for plane-strain fracture toughness of metallic materials
    • American Society for Testing and Materials. E399-83 Standard, West Conschocken, PA: American Society for Testing and Materials;
    • American Society for Testing and Materials. E399-83 Standard test method for plane-strain fracture toughness of metallic materials. West Conschocken, PA: American Society for Testing and Materials; 1983.
    • (1983)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.