메뉴 건너뛰기




Volumn 7082, Issue , 2008, Pages

Calibration of the spectral radiant power responsivity of windowed pyroelectric radiometers from 785 nm to 14 μm

Author keywords

Absolute cryogenic radiometer; Detector absorptance; Domed pyroelectric transfer standard; FTIR; OPO tunable laser; Pyroelectric radiometer with KRS5 window; Spectral radiant power responsivity; Stabilized CO2 laser

Indexed keywords

CALIBRATION; INSTRUMENTS; LASERS; PYROELECTRICITY; RADIOMETERS; RADIOMETRY; REMOTE SENSING; SPACE OPTICS; STANDARDS;

EID: 52349110974     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.799665     Document Type: Conference Paper
Times cited : (3)

References (6)
  • 1
    • 33747663763 scopus 로고    scopus 로고
    • Development and calibration of pyroelectric radiometer standards at NIST
    • G. Eppeldauer, J. Zeng, and L.M. Hanssen, "Development and calibration of pyroelectric radiometer standards at NIST," Proc. SPIE 6201, 620119 (2006).
    • (2006) Proc. SPIE , vol.6201 , pp. 620119
    • Eppeldauer, G.1    Zeng, J.2    Hanssen, L.M.3
  • 2
    • 52349090247 scopus 로고    scopus 로고
    • G. P. Eppeldauer, J. Zeng and L. M. Hanssen Spectral responsivity scale between 1 μm and 19 μm at NIST, in Proc. NEWRAD 2005, ed. by J. Groebner, PMODWRC, Davos, Switzerland, 241-242 (2005).
    • G. P. Eppeldauer, J. Zeng and L. M. Hanssen "Spectral responsivity scale between 1 μm and 19 μm at NIST," in Proc. NEWRAD 2005, ed. by J. Groebner, PMODWRC, Davos, Switzerland, 241-242 (2005).
  • 3
    • 0001322781 scopus 로고    scopus 로고
    • Development of a monochromatic, uniform source facility for calibration of radiance and irradiance detectors from 0.2 μm to 12 μm
    • Lykke K. R., Shaw P.-S., Hanssen L. M., and Eppeldauer G. P., " Development of a monochromatic, uniform source facility for calibration of radiance and irradiance detectors from 0.2 μm to 12 μm," Metrologia, 35, 479-484 (1998).
    • (1998) Metrologia , vol.35 , pp. 479-484
    • Lykke, K.R.1    Shaw, P.-S.2    Hanssen, L.M.3    Eppeldauer, G.P.4
  • 4
    • 3042633450 scopus 로고    scopus 로고
    • Spatial and angular responsivity measurements of photoconductive HgCdTe LWIR Radiometers
    • H. Gong, L. M. Hanssen and G. P. Eppeldauer, "Spatial and angular responsivity measurements of photoconductive HgCdTe LWIR Radiometers," Metrologia, 4, 161-166 (2004).
    • (2004) Metrologia , vol.4 , pp. 161-166
    • Gong, H.1    Hanssen, L.M.2    Eppeldauer, G.P.3
  • 5
    • 0001564676 scopus 로고    scopus 로고
    • Integrating-sphere system and method for absolute measurement of transmittance, reflectance, and absorptance of specular samples
    • L.M. Hanssen, "Integrating-sphere system and method for absolute measurement of transmittance, reflectance, and absorptance of specular samples," Applied Optics 40 (19), 3196-3204 (2001).
    • (2001) Applied Optics , vol.40 , Issue.19 , pp. 3196-3204
    • Hanssen, L.M.1
  • 6
    • 0345283320 scopus 로고    scopus 로고
    • Linearity characterization of NIST's infrared regular transmittance and reflectance scales
    • L.M. Hanssen, and S.G. Kaplan, "Linearity characterization of NIST's infrared regular transmittance and reflectance scales," Proc. SPIE 4826, 21-26 (2003).
    • (2003) Proc. SPIE , vol.4826 , pp. 21-26
    • Hanssen, L.M.1    Kaplan, S.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.