메뉴 건너뛰기




Volumn , Issue , 2008, Pages 1164-1168

Analysis of high and low voltage grid failure propagation in large wind farms considering transformers, cables and VAR-compensators

Author keywords

[No Author keywords available]

Indexed keywords

CABLES; CAPACITORS; CODES (STANDARDS); CODES (SYMBOLS); CRACK PROPAGATION; DISTRIBUTED PARAMETER NETWORKS; DISTRIBUTION OF GOODS; ELECTRIC FAULT CURRENTS; ELECTRIC GENERATORS; ELECTRIC POWER DISTRIBUTION; ELECTRIC UTILITIES; ENERGY STORAGE; FAILURE ANALYSIS; FARMS; PARKS; POWER ELECTRONICS; QUALITY ASSURANCE; RELIABILITY; WIND EFFECTS;

EID: 52349091386     PISSN: 02759306     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PESC.2008.4592087     Document Type: Conference Paper
Times cited : (5)

References (12)
  • 3
    • 52349117756 scopus 로고    scopus 로고
    • Eltra, Wind turbines connected to grids with voltages above 100 kV - Technical regulations for the properties and the control of wind turbines, Energinet.dk, Transmission System Operator of Denmark for Natural Gas and Electricity, Technical Regulations TF 3.2.5, 2004, pp 35.
    • Eltra, "Wind turbines connected to grids with voltages above 100 kV - Technical regulations for the properties and the control of wind turbines", Energinet.dk, Transmission System Operator of Denmark for Natural Gas and Electricity, Technical Regulations TF 3.2.5, 2004, pp 35.
  • 5
    • 33847646777 scopus 로고    scopus 로고
    • Ride-Through Analysis of Doubly Fed Induction Wind-Power Generator Under Unsymmetrical Network Disturbance
    • Nov
    • S. Seman, J. Niiranen, A. Arkkio, "Ride-Through Analysis of Doubly Fed Induction Wind-Power Generator Under Unsymmetrical Network Disturbance", IEEE Transactions on Power Systems, Nov. 2006, 21(4), pp 1782-1789.
    • (2006) IEEE Transactions on Power Systems , vol.21 , Issue.4 , pp. 1782-1789
    • Seman, S.1    Niiranen, J.2    Arkkio, A.3
  • 7
    • 33947709791 scopus 로고    scopus 로고
    • Modelling and Analysis of Variable Speed Wind Turbines with Induction Generator during Grid Fault
    • Denmark
    • S. M. Bolik, "Modelling and Analysis of Variable Speed Wind Turbines with Induction Generator during Grid Fault", thesis, Institute of Energy Technology, Aalborg University, Denmark, 2004.
    • (2004) thesis, Institute of Energy Technology, Aalborg University
    • Bolik, S.M.1
  • 8
    • 52349097205 scopus 로고    scopus 로고
    • D. Schulz, Integration von Windkraftanlagen in Energieversorgungsnetze - Stand der Technik und Perspektiven für die dezentrale Stromerzeugung, habilitation treatise, TU Berlin, VDE Verlag, Berlin, Offenbach, 2006 (German).
    • D. Schulz, "Integration von Windkraftanlagen in Energieversorgungsnetze - Stand der Technik und Perspektiven für die dezentrale Stromerzeugung", habilitation treatise, TU Berlin, VDE Verlag, Berlin, Offenbach, 2006 (German).
  • 9
    • 50249113096 scopus 로고    scopus 로고
    • D. Schulz, R. Hanitsch, Power Factor Adjustment and Energy Management in Large Grid-Connected Wind Parks, IECON 2006. -32nd Annual Converence on IEEE Industrial Electronics, Nov. 2006, pp 4201-4206.G. Herold, Elektrische Energieversorgung II, J. Schlembach Verlag, Weil der Stadt, 2001 (German).
    • D. Schulz, R. Hanitsch, "Power Factor Adjustment and Energy Management in Large Grid-Connected Wind Parks", IECON 2006. -32nd Annual Converence on IEEE Industrial Electronics, Nov. 2006, pp 4201-4206.G. Herold, "Elektrische Energieversorgung II", J. Schlembach Verlag, Weil der Stadt, 2001 (German).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.