메뉴 건너뛰기




Volumn 34, Issue 10, 2008, Pages 1631-1636

Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ANALYTICAL ERROR; APHAKIA; ARTICLE; ASTIGMATISM; LENS IMPLANT; LENS IMPLANTATION; MATHEMATICAL ANALYSIS; PATIENT POSITIONING; PRIORITY JOURNAL; REFRACTIVE SURGERY; SLIT LAMP; SURGICAL APPROACH; SURGICAL PATIENT; SURGICAL TECHNIQUE;

EID: 52249110661     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2008.04.041     Document Type: Article
Times cited : (112)

References (22)
  • 1
    • 0038441686 scopus 로고    scopus 로고
    • Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases
    • Chang D.F. Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases. J Cataract Refract Surg 29 (2003) 935-940
    • (2003) J Cataract Refract Surg , vol.29 , pp. 935-940
    • Chang, D.F.1
  • 2
    • 0033766516 scopus 로고    scopus 로고
    • Toric intraocular lenses for correcting astigmatism in 130 eyes
    • discussion by RM Kershner, 1781-1782
    • Sun X.-Y., Vicary D., Montgomery P., and Griffiths M. Toric intraocular lenses for correcting astigmatism in 130 eyes. Ophthalmology 107 (2000) 1776-1781 discussion by RM Kershner, 1781-1782
    • (2000) Ophthalmology , vol.107 , pp. 1776-1781
    • Sun, X.-Y.1    Vicary, D.2    Montgomery, P.3    Griffiths, M.4
  • 3
    • 0023153567 scopus 로고
    • Centering corneal surgical procedures
    • correction, 852
    • Uozato H., and Guyton D.L. Centering corneal surgical procedures. Am J Ophthalmol 103 (1987) 264-275 correction, 852
    • (1987) Am J Ophthalmol , vol.103 , pp. 264-275
    • Uozato, H.1    Guyton, D.L.2
  • 4
    • 0023882016 scopus 로고
    • The effect of pupil centration and diameter on ocular performance
    • Walsh G., and Charman W.N. The effect of pupil centration and diameter on ocular performance. Vision Res 28 (1988) 659-665
    • (1988) Vision Res , vol.28 , pp. 659-665
    • Walsh, G.1    Charman, W.N.2
  • 6
    • 0027210022 scopus 로고
    • Optical zone centration in keratorefractive surgery; entrance pupil center, visual axis, coaxially sighted corneal reflex, or geometric corneal center?
    • Pande M., and Hillman J.S. Optical zone centration in keratorefractive surgery; entrance pupil center, visual axis, coaxially sighted corneal reflex, or geometric corneal center?. Ophthalmology 100 (1993) 1230-1237
    • (1993) Ophthalmology , vol.100 , pp. 1230-1237
    • Pande, M.1    Hillman, J.S.2
  • 7
    • 27144431945 scopus 로고    scopus 로고
    • Measurement of the spatial shift of the pupil center
    • Camellin M., Gambino F., and Casaro S. Measurement of the spatial shift of the pupil center. J Cataract Refract Surg 31 (2005) 1719-1721
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1719-1721
    • Camellin, M.1    Gambino, F.2    Casaro, S.3
  • 8
    • 0023905163 scopus 로고
    • Ocular torsion: sensorimotor principles
    • Guyton D.L. Ocular torsion: sensorimotor principles. Graefes Arch Clin Exp Ophthalmol 226 (1988) 241-245
    • (1988) Graefes Arch Clin Exp Ophthalmol , vol.226 , pp. 241-245
    • Guyton, D.L.1
  • 9
    • 0028414174 scopus 로고
    • Ocular torsion quantification with video images
    • Bos J.E., and de Graaf B. Ocular torsion quantification with video images. IEEE Trans Biomed Eng 41 (1994) 351-357
    • (1994) IEEE Trans Biomed Eng , vol.41 , pp. 351-357
    • Bos, J.E.1    de Graaf, B.2
  • 10
    • 0035344149 scopus 로고    scopus 로고
    • Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations
    • Guirao A., Williams D.R., and Cox I.G. Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations. J Opt Soc Am A Opt Image Sci Vis 18 (2001) 1003-1015
    • (2001) J Opt Soc Am A Opt Image Sci Vis , vol.18 , pp. 1003-1015
    • Guirao, A.1    Williams, D.R.2    Cox, I.G.3
  • 11
  • 13
    • 1542616361 scopus 로고    scopus 로고
    • Use of preoperative assessment of positionally induced cyclotorsion: a video-oculographic study
    • Becker R., Krzizok T.H., and Wassill H. Use of preoperative assessment of positionally induced cyclotorsion: a video-oculographic study. Br J Ophthalmol 88 (2004) 417-421
    • (2004) Br J Ophthalmol , vol.88 , pp. 417-421
    • Becker, R.1    Krzizok, T.H.2    Wassill, H.3
  • 14
    • 1842476884 scopus 로고    scopus 로고
    • Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery
    • Chernyak D.A. Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery. J Cataract Refract Surg 30 (2004) 633-638
    • (2004) J Cataract Refract Surg , vol.30 , pp. 633-638
    • Chernyak, D.A.1
  • 18
    • 0017739210 scopus 로고
    • Prescribing cylinders: the problem of distortion
    • Guyton D.L. Prescribing cylinders: the problem of distortion. Surv Ophthalmol 22 (1977) 177-188
    • (1977) Surv Ophthalmol , vol.22 , pp. 177-188
    • Guyton, D.L.1
  • 19
    • 0033504828 scopus 로고    scopus 로고
    • Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants
    • discussion by DJ Apple, 2196
    • Patel C.K., Ormonde S., Rosen P.H., and Bron A.J. Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants. Ophthalmology 106 (1999) 2190-2195 discussion by DJ Apple, 2196
    • (1999) Ophthalmology , vol.106 , pp. 2190-2195
    • Patel, C.K.1    Ormonde, S.2    Rosen, P.H.3    Bron, A.J.4
  • 21
    • 0346787902 scopus 로고    scopus 로고
    • Linear-long incisions with a small optical zone for the correction of astigmatism in older patients
    • Ho H.-C., Chen K.-H., Hsu W.-M., Lee S.-M., Chiang C.-C., and Li Y.-S. Linear-long incisions with a small optical zone for the correction of astigmatism in older patients. Ophthalmology 111 (2004) 28-33
    • (2004) Ophthalmology , vol.111 , pp. 28-33
    • Ho, H.-C.1    Chen, K.-H.2    Hsu, W.-M.3    Lee, S.-M.4    Chiang, C.-C.5    Li, Y.-S.6