메뉴 건너뛰기




Volumn 34, Issue , 2007, Pages 407-410

Comparison of signal peak detection algorithms for self-gated cardiac cine MRI

Author keywords

[No Author keywords available]

Indexed keywords

CARDIAC CYCLES; CARDIAC MRIS; CINE MRIS; HEALTHY SUBJECTS; MR SIGNALS; PEAK DETECTIONS; RMS ERRORS; ROOT-MEAN-SQUARE ERRORS;

EID: 52149109323     PISSN: 02766574     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CIC.2007.4745508     Document Type: Conference Paper
Times cited : (6)

References (11)
  • 1
    • 0020327391 scopus 로고
    • The effect of rapid rise-time magnetic fields on the ECG of the rat
    • Polson MJR, Barker AT, Gardiner S. The effect of rapid rise-time magnetic fields on the ECG of the rat. Clin Phys Physiol Meas 1982;3(3):231-234.
    • (1982) Clin Phys Physiol Meas , vol.3 , Issue.3 , pp. 231-234
    • Polson, M.J.R.1    Barker, A.T.2    Gardiner, S.3
  • 3
    • 0024227392 scopus 로고
    • RF interference suppression in a cardiac synchronization system operating in a high magnetic field NMR imaging system
    • Damji AA, Snyder RE, Ellinger DC, Witkowski RX, Allen PS. RF interference suppression in a cardiac synchronization system operating in a high magnetic field NMR imaging system. Magn Reson Imaging 1988:6;637- 640.
    • (1988) Magn Reson Imaging , vol.6 , pp. 637-640
    • Damji, A.A.1    Snyder, R.E.2    Ellinger, D.C.3    Witkowski, R.X.4    Allen, P.S.5
  • 4
    • 0023684480 scopus 로고
    • Suppression of radiofrequency interference in cardiac gated MRI: A simple design
    • Shetty AN. Suppression of radiofrequency interference in cardiac gated MRI: a simple design. Magn Reson Med 1988:8;84-88.
    • (1988) Magn Reson Med , vol.8 , pp. 84-88
    • Shetty, A.N.1
  • 5
    • 0014063724 scopus 로고    scopus 로고
    • Togawa T, Okai O, Oshima M. Observation of blood flow e.m.f. in externally applied strong magnetic field by surface electrodes. Med Biol Eng 1967;5(2):169-70.
    • Togawa T, Okai O, Oshima M. Observation of blood flow e.m.f. in externally applied strong magnetic field by surface electrodes. Med Biol Eng 1967;5(2):169-70.
  • 6
    • 8844279222 scopus 로고    scopus 로고
    • Magnetically induced electric fields and currents in the circulatory system
    • Tenforde TS. Magnetically induced electric fields and currents in the circulatory system. Prog Biophys Mol Biol 2005;87(2-3):279-88.
    • (2005) Prog Biophys Mol Biol , vol.87 , Issue.2-3 , pp. 279-288
    • Tenforde, T.S.1
  • 7
    • 0032873080 scopus 로고    scopus 로고
    • Novel real-time R- wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions
    • Fischer SE, Wickline SA, Lorenz CH. Novel real-time R- wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 1999;42(2):361-370.
    • (1999) Magn Reson Med , vol.42 , Issue.2 , pp. 361-370
    • Fischer, S.E.1    Wickline, S.A.2    Lorenz, C.H.3
  • 8
    • 0033761052 scopus 로고    scopus 로고
    • Performance of QRS detection for cardiac magnetic resonance imaging with a novel vectorcardiographic triggering method
    • Chia JM, Fischer SE, Wickline SA, Lorenz CH. Performance of QRS detection for cardiac magnetic resonance imaging with a novel vectorcardiographic triggering method. J Magn Reson Imaging 2000;12:678-688.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 678-688
    • Chia, J.M.1    Fischer, S.E.2    Wickline, S.A.3    Lorenz, C.H.4
  • 11
    • 4243109557 scopus 로고    scopus 로고
    • Flow-gated phase-contrast MRI using radial acquisitions
    • Thompson RB, McVeigh ER. Flow-gated phase-contrast MRI using radial acquisitions. Magn Reson Med 2004:52;598-604.
    • (2004) Magn Reson Med , vol.52 , pp. 598-604
    • Thompson, R.B.1    McVeigh, E.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.