메뉴 건너뛰기




Volumn 15, Issue 6, 2008, Pages 493-498

Systematic review of emergency physician-performed ultrasonography for lower-extremity deep vein thrombosis

Author keywords

Deep vein thrombosis; Emergency department; Systematic review; Ultrasound

Indexed keywords

ARTICLE; DEEP VEIN THROMBOSIS; DIAGNOSTIC ACCURACY; ECHOGRAPHY; EMBASE; EMERGENCY PHYSICIAN; HUMAN; MEDLINE; PRIORITY JOURNAL; ROC CURVE; SCREENING; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW; EMERGENCY HEALTH SERVICE; LEG; REVIEW; VASCULARIZATION; VEIN THROMBOSIS;

EID: 52049123161     PISSN: 10696563     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1553-2712.2008.00101.x     Document Type: Article
Times cited : (97)

References (28)
  • 1
    • 28344456034 scopus 로고    scopus 로고
    • Venous thromboembolism: Disease burden, outcomes and risk factors
    • Heit JA. Venous thromboembolism: disease burden, outcomes and risk factors. J Thromb Haemost. 2005; 3:1611-7.
    • (2005) J Thromb Haemost , vol.3 , pp. 1611-1617
    • Heit, J.A.1
  • 2
    • 0035192216 scopus 로고    scopus 로고
    • Identification of prearrest clinical factors associated with outpatient fatal pulmonary embolism
    • Courtney DM, Kline JA. Identification of prearrest clinical factors associated with outpatient fatal pulmonary embolism. Acad Emerg Med. 2001; 8:1136-42.
    • (2001) Acad Emerg Med , vol.8 , pp. 1136-1142
    • Courtney, D.M.1    Kline, J.A.2
  • 3
    • 13844320299 scopus 로고    scopus 로고
    • The mortality of untreated pulmonary embolism in emergency department patients
    • Calder KK, Herbert M, Henderson SO. The mortality of untreated pulmonary embolism in emergency department patients. Ann Emerg Med. 2005; 45:302-10.
    • (2005) Ann Emerg Med , vol.45 , pp. 302-310
    • Calder, K.K.1    Herbert, M.2    Henderson, S.O.3
  • 4
    • 33846668916 scopus 로고    scopus 로고
    • Management of venous thromboembolism: A clinical practice guideline from the American College of Physicians and the American Academy of Family Physicians
    • Snow V, Qaseem A, Barry P, et al. Management of venous thromboembolism: a clinical practice guideline from the American College of Physicians and the American Academy of Family Physicians. Ann Intern Med. 2007; 146:204-10.
    • (2007) Ann Intern Med , vol.146 , pp. 204-210
    • Snow, V.1    Qaseem, A.2    Barry, P.3
  • 5
    • 4143121708 scopus 로고    scopus 로고
    • D-dimer for the exclusion of acute venous thrombosis and pulmonary embolism: A systematic review
    • Stein PD, Hull RD, Patel KC, et al. D-dimer for the exclusion of acute venous thrombosis and pulmonary embolism: a systematic review. Ann Intern Med. 2004; 140:589-602.
    • (2004) Ann Intern Med , vol.140 , pp. 589-602
    • Stein, P.D.1    Hull, R.D.2    Patel, K.C.3
  • 6
    • 31044452471 scopus 로고    scopus 로고
    • Ultrasonography in community emergency departments in the United States: Access to ultrasonography performed by consultants and status of emergency physician-performed ultrasonography
    • Moore CL, Molina AA, Lin H. Ultrasonography in community emergency departments in the United States: access to ultrasonography performed by consultants and status of emergency physician-performed ultrasonography. Ann Emerg Med. 2006; 47:147-53.
    • (2006) Ann Emerg Med , vol.47 , pp. 147-153
    • Moore, C.L.1    Molina, A.A.2    Lin, H.3
  • 7
    • 34247340186 scopus 로고    scopus 로고
    • History of emergency and critical care ultrasound: The evolution of a new imaging paradigm
    • Kendall JL, Hoffenberg SR, Smith RS. History of emergency and critical care ultrasound: the evolution of a new imaging paradigm. Crit Care Med. 2007; 35(5 Suppl):S126-S130.
    • (2007) Crit Care Med , vol.35 , Issue.5 SUPPL.
    • Kendall, J.L.1    Hoffenberg, S.R.2    Smith, R.S.3
  • 8
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol. 2003; 3:25.
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3    Bossuyt, P.M.4    Kleijnen, J.5
  • 10
    • 85045417272 scopus 로고    scopus 로고
    • A methodological review of how heterogeneity has been examined in systematic reviews of diagnostic test accuracy
    • Dinnes J, Deeks J, Kirby J, Roderick P. A methodological review of how heterogeneity has been examined in systematic reviews of diagnostic test accuracy. Health Technol Assess. 2005; 9:1-113.
    • (2005) Health Technol Assess , vol.9 , pp. 1-113
    • Dinnes, J.1    Deeks, J.2    Kirby, J.3    Roderick, P.4
  • 13
    • 27444440823 scopus 로고    scopus 로고
    • Novel protein markers of acute coronary syndrome complications in low-risk outpatients: A systematic review of potential use in the emergency department
    • Mitchell AM, Brown MD, Menown IB, Kline JA. Novel protein markers of acute coronary syndrome complications in low-risk outpatients: a systematic review of potential use in the emergency department. Clin Chem. 2005; 51:2005-12.
    • (2005) Clin Chem , vol.51 , pp. 2005-2012
    • Mitchell, A.M.1    Brown, M.D.2    Menown, I.B.3    Kline, J.A.4
  • 14
    • 0027290944 scopus 로고
    • Combining independent studies of a diagnostic test into a summary ROC curve: Data-analytic approaches and some additional considerations
    • Moses LE, Shapiro D, Littenberg B. Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med. 1993; 12:1293-316.
    • (1993) Stat Med , vol.12 , pp. 1293-1316
    • Moses, L.E.1    Shapiro, D.2    Littenberg, B.3
  • 15
    • 20544452564 scopus 로고    scopus 로고
    • Challenges in systematic reviews of diagnostic technologies
    • Tatsioni A, Zarin DA, Aronson N, et al. Challenges in systematic reviews of diagnostic technologies. Ann Intern Med. 2005; 142:1048-55.
    • (2005) Ann Intern Med , vol.142 , pp. 1048-1055
    • Tatsioni, A.1    Zarin, D.A.2    Aronson, N.3
  • 16
    • 23644457189 scopus 로고    scopus 로고
    • In an empirical evaluation of the funnel plot, researchers could not visually identify publication bias
    • Terrin N, Schmid CH, Lau J. In an empirical evaluation of the funnel plot, researchers could not visually identify publication bias. J Clin Epidemiol. 2005; 58:894-901.
    • (2005) J Clin Epidemiol , vol.58 , pp. 894-901
    • Terrin, N.1    Schmid, C.H.2    Lau, J.3
  • 17
    • 0033974761 scopus 로고    scopus 로고
    • Lower-extremity Doppler for deep venous thrombosis-can emergency physicians be accurate and fast?
    • Blaivas M, Lambert MJ, Harwood RA, Wood JP, Konicki J. Lower-extremity Doppler for deep venous thrombosis-can emergency physicians be accurate and fast? Acad Emerg Med. 2000; 7:120-6.
    • (2000) Acad Emerg Med , vol.7 , pp. 120-126
    • Blaivas, M.1    Lambert, M.J.2    Harwood, R.A.3    Wood, J.P.4    Konicki, J.5
  • 18
    • 0035121382 scopus 로고    scopus 로고
    • Emergency Department compression ultrasound to diagnose proximal deep vein thrombosis
    • Frazee BW, Snoey ER, Levitt A. Emergency Department compression ultrasound to diagnose proximal deep vein thrombosis. J Emerg Med. 2001; 20:107-12.
    • (2001) J Emerg Med , vol.20 , pp. 107-112
    • Frazee, B.W.1    Snoey, E.R.2    Levitt, A.3
  • 19
    • 1642327681 scopus 로고    scopus 로고
    • Resident-performed compression ultrasonography for the detection of proximal deep vein thrombosis: Fast and accurate
    • Jang T, Docherty M, Aubin C, Polites G. Resident-performed compression ultrasonography for the detection of proximal deep vein thrombosis: fast and accurate. Acad Emerg Med. 2004; 11:319-22.
    • (2004) Acad Emerg Med , vol.11 , pp. 319-322
    • Jang, T.1    Docherty, M.2    Aubin, C.3    Polites, G.4
  • 20
    • 2442716559 scopus 로고    scopus 로고
    • Theodoro D, Blaivas M, Duggal S, Snyder G, Lucas M. Real-time B-mode ultrasound in the ED saves time in the diagnosis of deep vein thrombosis (DVT). Am J Emerg Med. 2004; 22:197-200.
    • Theodoro D, Blaivas M, Duggal S, Snyder G, Lucas M. Real-time B-mode ultrasound in the ED saves time in the diagnosis of deep vein thrombosis (DVT). Am J Emerg Med. 2004; 22:197-200.
  • 21
    • 33847326356 scopus 로고    scopus 로고
    • Can emergency medicine residents detect acute deep venous thrombosis with a limited, two-site ultrasound examination?
    • Jacoby J, Cesta M, Axelband J, Melanson S, Heller M, Reed J. Can emergency medicine residents detect acute deep venous thrombosis with a limited, two-site ultrasound examination? J Emerg Med. 2007; 32:197-200.
    • (2007) J Emerg Med , vol.32 , pp. 197-200
    • Jacoby, J.1    Cesta, M.2    Axelband, J.3    Melanson, S.4    Heller, M.5    Reed, J.6
  • 22
    • 33847188122 scopus 로고    scopus 로고
    • Duplex ultrasound in the emergency department for the diagnostic management of clinically suspected deep vein thrombosis
    • Magazzini S, Vanni S, Toccafondi S, et al. Duplex ultrasound in the emergency department for the diagnostic management of clinically suspected deep vein thrombosis. Acad Emerg Med. 2007; 14:216-20.
    • (2007) Acad Emerg Med , vol.14 , pp. 216-220
    • Magazzini, S.1    Vanni, S.2    Toccafondi, S.3
  • 23
    • 2442478534 scopus 로고    scopus 로고
    • Performance, training, quality assurance, and reimbursement of emergency physician-performed ultrasonography at academic medical centers
    • Moore CL, Gregg S, Lambert M. Performance, training, quality assurance, and reimbursement of emergency physician-performed ultrasonography at academic medical centers. J Ultrasound Med. 2004; 23:459-66.
    • (2004) J Ultrasound Med , vol.23 , pp. 459-466
    • Moore, C.L.1    Gregg, S.2    Lambert, M.3
  • 26
    • 0034750208 scopus 로고    scopus 로고
    • Therapy of isolated calf muscle vein thrombosis with low-molecular-weight heparin
    • Schwarz T, Schmidt B, Beyer J, Schellong SM. Therapy of isolated calf muscle vein thrombosis with low-molecular-weight heparin. Blood Coagul Fibrinolysis. 2001; 12:597-9.
    • (2001) Blood Coagul Fibrinolysis , vol.12 , pp. 597-599
    • Schwarz, T.1    Schmidt, B.2    Beyer, J.3    Schellong, S.M.4
  • 27
    • 23944444623 scopus 로고    scopus 로고
    • No role for quality scores in systematic reviews of diagnostic accuracy studies
    • Whiting P, Harbord R, Kleijnen J. No role for quality scores in systematic reviews of diagnostic accuracy studies. BMC Med Res Methodol. 2005; 5:19.
    • (2005) BMC Med Res Methodol , vol.5 , pp. 19
    • Whiting, P.1    Harbord, R.2    Kleijnen, J.3
  • 28
    • 23644432857 scopus 로고    scopus 로고
    • The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed
    • Deeks JJ, Macaskill P, Irwig L. The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol. 2005; 58:882-93.
    • (2005) J Clin Epidemiol , vol.58 , pp. 882-893
    • Deeks, J.J.1    Macaskill, P.2    Irwig, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.