메뉴 건너뛰기




Volumn 100, Issue 4, 2008, Pages 264-273

Influence of the type of post and core on in vitro marginal continuity, fracture resistance, and fracture mode of lithia disilicate-based all-ceramic crowns

Author keywords

[No Author keywords available]

Indexed keywords

LITHIA DISILICATE;

EID: 52049118606     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-3913(08)60205-X     Document Type: Article
Times cited : (71)

References (21)
  • 1
    • 33646351543 scopus 로고    scopus 로고
    • Impact of endodontic treatments on the rigidity of the root
    • Lang H., Korkmaz Y., Schneider K., and Raab W. Impact of endodontic treatments on the rigidity of the root. J Dent Res 85 (2006) 364-368
    • (2006) J Dent Res , vol.85 , pp. 364-368
    • Lang, H.1    Korkmaz, Y.2    Schneider, K.3    Raab, W.4
  • 2
    • 0032041958 scopus 로고    scopus 로고
    • Are posts mandatory for the restoration of endodontically treated teeth?
    • Stockton L., Lavelle C.L., and Suzuki M. Are posts mandatory for the restoration of endodontically treated teeth?. Endod Dent Traumatol 14 (1998) 59-63
    • (1998) Endod Dent Traumatol , vol.14 , pp. 59-63
    • Stockton, L.1    Lavelle, C.L.2    Suzuki, M.3
  • 3
    • 2442707655 scopus 로고    scopus 로고
    • Post placement and restoration of endodontically treated teeth: a literature review
    • Schwartz R.S., and Robbins J.W. Post placement and restoration of endodontically treated teeth: a literature review. J Endod 30 (2004) 289-301
    • (2004) J Endod , vol.30 , pp. 289-301
    • Schwartz, R.S.1    Robbins, J.W.2
  • 4
    • 0033233512 scopus 로고    scopus 로고
    • Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years-preliminary results
    • Bindl A., and Mörmann W.H. Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years-preliminary results. J Adhes Dent 1 (1999) 255-265
    • (1999) J Adhes Dent , vol.1 , pp. 255-265
    • Bindl, A.1    Mörmann, W.H.2
  • 5
    • 20444430522 scopus 로고    scopus 로고
    • Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry
    • Bindl A., Richter B., and Mörmann W.H. Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry. Int J Prosthodont 18 (2005) 219-224
    • (2005) Int J Prosthodont , vol.18 , pp. 219-224
    • Bindl, A.1    Richter, B.2    Mörmann, W.H.3
  • 6
    • 33646515795 scopus 로고    scopus 로고
    • Influence of different posts and cores on marginal adaptation, fracture resistance, and fracture mode of composite resin crowns on human mandibular premolars. An in vitro study
    • Stricker E.J., and Göhring T.N. Influence of different posts and cores on marginal adaptation, fracture resistance, and fracture mode of composite resin crowns on human mandibular premolars. An in vitro study. J Dent 34 (2006) 326-335
    • (2006) J Dent , vol.34 , pp. 326-335
    • Stricker, E.J.1    Göhring, T.N.2
  • 7
    • 0031317732 scopus 로고    scopus 로고
    • Clinical and quantitative marginal analysis of feldspathic ceramic inlays at 4 years
    • Friedl K.H., Hiller K.A., Schmalz G., and Bey B. Clinical and quantitative marginal analysis of feldspathic ceramic inlays at 4 years. Clin Oral Investig 1 (1997) 163-168
    • (1997) Clin Oral Investig , vol.1 , pp. 163-168
    • Friedl, K.H.1    Hiller, K.A.2    Schmalz, G.3    Bey, B.4
  • 8
    • 36549075075 scopus 로고    scopus 로고
    • A new in vitro model to study the relationship of gap size and secondary caries
    • Totiam P., Gonzalez-Cabezas C., Fontana M.R., and Zero D.T. A new in vitro model to study the relationship of gap size and secondary caries. Caries Res 41 (2007) 467-473
    • (2007) Caries Res , vol.41 , pp. 467-473
    • Totiam, P.1    Gonzalez-Cabezas, C.2    Fontana, M.R.3    Zero, D.T.4
  • 9
    • 0033129136 scopus 로고    scopus 로고
    • Stiffness, elastic limit, and strength of newer types of endodontic posts
    • Asmussen E., Peutzfeldt A., and Heitmann T. Stiffness, elastic limit, and strength of newer types of endodontic posts. J Dent 27 (1999) 275-278
    • (1999) J Dent , vol.27 , pp. 275-278
    • Asmussen, E.1    Peutzfeldt, A.2    Heitmann, T.3
  • 10
    • 0033144123 scopus 로고    scopus 로고
    • Thermal and cyclic loading of endodontic posts
    • Drummond J.L., Toepke T.R., and King T.J. Thermal and cyclic loading of endodontic posts. Eur J Oral Sci 107 (1999) 220-224
    • (1999) Eur J Oral Sci , vol.107 , pp. 220-224
    • Drummond, J.L.1    Toepke, T.R.2    King, T.J.3
  • 11
    • 0035432508 scopus 로고    scopus 로고
    • Fracture strength and survival rate of endodontically treated maxillary incisors with approximal cavities after restoration with different post and core systems: an in-vitro study
    • Heydecke G., Butz F., and Strub J.R. Fracture strength and survival rate of endodontically treated maxillary incisors with approximal cavities after restoration with different post and core systems: an in-vitro study. J Dent 29 (2001) 427-433
    • (2001) J Dent , vol.29 , pp. 427-433
    • Heydecke, G.1    Butz, F.2    Strub, J.R.3
  • 12
    • 0026182820 scopus 로고
    • Failure of endodontically treated teeth: classification and evaluation
    • Vire D.E. Failure of endodontically treated teeth: classification and evaluation. J Endod 17 (1991) 338-342
    • (1991) J Endod , vol.17 , pp. 338-342
    • Vire, D.E.1
  • 13
    • 0036728926 scopus 로고    scopus 로고
    • Effect of core stiffness on the in vitro fracture of crowned, endodontically treated teeth
    • Pilo R., Cardash H.S., Levin E., and Assif D. Effect of core stiffness on the in vitro fracture of crowned, endodontically treated teeth. J Prosthet Dent 88 (2002) 302-306
    • (2002) J Prosthet Dent , vol.88 , pp. 302-306
    • Pilo, R.1    Cardash, H.S.2    Levin, E.3    Assif, D.4
  • 14
    • 0035294362 scopus 로고    scopus 로고
    • In vitro comparison of the fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restoration
    • Cormier C.T., Burns D.R., and Moon P. In vitro comparison of the fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restoration. J Prosthodont 10 (2001) 26-36
    • (2001) J Prosthodont , vol.10 , pp. 26-36
    • Cormier, C.T.1    Burns, D.R.2    Moon, P.3
  • 15
    • 0037977839 scopus 로고    scopus 로고
    • Fracture resistance of endodontically treated teeth restored with three different prefabricated esthetic posts
    • Maccari P.C., Conceicao E.N., and Nunes M.F. Fracture resistance of endodontically treated teeth restored with three different prefabricated esthetic posts. J Esthet Restor Dent 15 (2003) 25-30
    • (2003) J Esthet Restor Dent , vol.15 , pp. 25-30
    • Maccari, P.C.1    Conceicao, E.N.2    Nunes, M.F.3
  • 16
    • 0036249846 scopus 로고    scopus 로고
    • Finite element analysis of a glass fibre reinforced composite endodontic post
    • Pegoretti A., Fambri L., Zappini G., and Bianchetti M. Finite element analysis of a glass fibre reinforced composite endodontic post. Biomaterials 23 (2002) 2667-2682
    • (2002) Biomaterials , vol.23 , pp. 2667-2682
    • Pegoretti, A.1    Fambri, L.2    Zappini, G.3    Bianchetti, M.4
  • 17
    • 14844290341 scopus 로고    scopus 로고
    • Randomized clinical comparison of endodontically treated teeth restored with amalgam or with fiber posts and resin composite: five-year results
    • Mannocci F., Qualtrough A.J., Worthington H.V., Watson T.F., and Pitt Ford T.R. Randomized clinical comparison of endodontically treated teeth restored with amalgam or with fiber posts and resin composite: five-year results. Oper Dent 30 (2005) 9-15
    • (2005) Oper Dent , vol.30 , pp. 9-15
    • Mannocci, F.1    Qualtrough, A.J.2    Worthington, H.V.3    Watson, T.F.4    Pitt Ford, T.R.5
  • 18
    • 18744427214 scopus 로고    scopus 로고
    • A literature review on the prosthetic treatment of structurally compromised teeth
    • Torbjorner A., and Fransson B. A literature review on the prosthetic treatment of structurally compromised teeth. Int J Prosthodont 17 (2004) 369-376
    • (2004) Int J Prosthodont , vol.17 , pp. 369-376
    • Torbjorner, A.1    Fransson, B.2
  • 19
    • 4344632971 scopus 로고    scopus 로고
    • A structured analysis of in vitro failure loads and failure modes of fiber, metal, and ceramic post-and-core systems
    • Fokkinga W.A., Kreulen C.M., Vallittu P.K., and Creugers N.H. A structured analysis of in vitro failure loads and failure modes of fiber, metal, and ceramic post-and-core systems. Int J Prosthodont 17 (2004) 476-482
    • (2004) Int J Prosthodont , vol.17 , pp. 476-482
    • Fokkinga, W.A.1    Kreulen, C.M.2    Vallittu, P.K.3    Creugers, N.H.4
  • 20
    • 0029294799 scopus 로고
    • The effect of load angulation on fracture resistance of teeth restored with cast post and cores and crowns
    • Loney R.W., Moulding M.B., and Ritsco R.G. The effect of load angulation on fracture resistance of teeth restored with cast post and cores and crowns. Int J Prosthodont 8 (1995) 247-251
    • (1995) Int J Prosthodont , vol.8 , pp. 247-251
    • Loney, R.W.1    Moulding, M.B.2    Ritsco, R.G.3
  • 21
    • 0036546561 scopus 로고    scopus 로고
    • Resistance to fracture of endodontically treated teeth restored with different post systems
    • Akkayan B., and Gulmez T. Resistance to fracture of endodontically treated teeth restored with different post systems. J Prosthet Dent 87 (2002) 431-437
    • (2002) J Prosthet Dent , vol.87 , pp. 431-437
    • Akkayan, B.1    Gulmez, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.