메뉴 건너뛰기




Volumn 28, Issue 4, 2008, Pages 680-686

Reliability of diabetic patients' gait parameters in a challenging environment

Author keywords

Diabetes; Gait; Reliability

Indexed keywords

ACCURACY; ADULT; ANALYTIC METHOD; ARTICLE; CLINICAL EXAMINATION; GAIT; HUMAN; HUMAN EXPERIMENT; KNEE; MEASUREMENT ERROR; NON INSULIN DEPENDENT DIABETES MELLITUS; PRIORITY JOURNAL; RELIABILITY; SENSOR; WALKING;

EID: 52049086890     PISSN: 09666362     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2008.05.006     Document Type: Article
Times cited : (22)

References (28)
  • 1
    • 23844513274 scopus 로고    scopus 로고
    • A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes
    • Dejnabadi H., Jolles B.M., and Aminian K. A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes. IEEE Trans Biomed Eng 52 (2005) 1478-1484
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 1478-1484
    • Dejnabadi, H.1    Jolles, B.M.2    Aminian, K.3
  • 2
    • 2942627630 scopus 로고    scopus 로고
    • Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement
    • Aminian K., Trevisan C., Najafi B., Dejnabadi H., Frigo C., Pavan E., et al. Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement. Gait Posture 20 (2004) 102-107
    • (2004) Gait Posture , vol.20 , pp. 102-107
    • Aminian, K.1    Trevisan, C.2    Najafi, B.3    Dejnabadi, H.4    Frigo, C.5    Pavan, E.6
  • 3
    • 7444242812 scopus 로고    scopus 로고
    • Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems
    • Simon S.R. Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems. J Biomech 37 (2004) 1869-1880
    • (2004) J Biomech , vol.37 , pp. 1869-1880
    • Simon, S.R.1
  • 4
    • 23644438591 scopus 로고    scopus 로고
    • Gait analysis in a challenging environment differentiates between fallers and nonfallers among older patients with peripheral neuropathy
    • Richardson J.K., Thies S.B., DeMott T.K., and Ashton-Miller J.A. Gait analysis in a challenging environment differentiates between fallers and nonfallers among older patients with peripheral neuropathy. Arch Phys Med Rehabil 86 (2005) 1539-1544
    • (2005) Arch Phys Med Rehabil , vol.86 , pp. 1539-1544
    • Richardson, J.K.1    Thies, S.B.2    DeMott, T.K.3    Ashton-Miller, J.A.4
  • 5
    • 33748565321 scopus 로고    scopus 로고
    • Characteristics of falls in physically active community-dwelling older people: findings from the "Standfest im Alter" study. Article in German
    • Freiberger E., and Menz H.B. Characteristics of falls in physically active community-dwelling older people: findings from the "Standfest im Alter" study. Article in German. Z Gerontol Geriatr 39 (2006) 261-267
    • (2006) Z Gerontol Geriatr , vol.39 , pp. 261-267
    • Freiberger, E.1    Menz, H.B.2
  • 6
    • 0032998285 scopus 로고    scopus 로고
    • A practical gait analysis system using gyroscopes
    • Tong K., and Granat M.H. A practical gait analysis system using gyroscopes. Med Eng Phys 21 (1999) 87-94
    • (1999) Med Eng Phys , vol.21 , pp. 87-94
    • Tong, K.1    Granat, M.H.2
  • 7
    • 33847747867 scopus 로고    scopus 로고
    • Mobility assessment in older people: new possibilities and challenges
    • Zijlstra W., and Aminian K. Mobility assessment in older people: new possibilities and challenges. Eur J Aging 4 (2007) 1-12
    • (2007) Eur J Aging , vol.4 , pp. 1-12
    • Zijlstra, W.1    Aminian, K.2
  • 8
    • 37049031671 scopus 로고    scopus 로고
    • A body-fixed-sensor based analysis of compensatory trunk movements during unconstrained walking
    • Epub 12 April 2007
    • Zijlstra A., Goosen J.H., Verheyen C.C., and Zijlstra W. A body-fixed-sensor based analysis of compensatory trunk movements during unconstrained walking. Gait Posture 27 1 (2008) 164-167 Epub 12 April 2007
    • (2008) Gait Posture , vol.27 , Issue.1 , pp. 164-167
    • Zijlstra, A.1    Goosen, J.H.2    Verheyen, C.C.3    Zijlstra, W.4
  • 12
    • 0033060589 scopus 로고    scopus 로고
    • Physical activity monitoring based on accelerometry: validation and comparison with video observation
    • Aminian K., Robert P., Buchser E.E., Rutschmann B., Hayoz D., and Depairon M. Physical activity monitoring based on accelerometry: validation and comparison with video observation. Med Biol Eng Comput 37 (1999) 304-308
    • (1999) Med Biol Eng Comput , vol.37 , pp. 304-308
    • Aminian, K.1    Robert, P.2    Buchser, E.E.3    Rutschmann, B.4    Hayoz, D.5    Depairon, M.6
  • 15
    • 0036221730 scopus 로고    scopus 로고
    • Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
    • Aminian K., Najafi B., Bula C., Leyvraz P.F., and Robert P. Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes. J Biomech 35 (2002) 689-699
    • (2002) J Biomech , vol.35 , pp. 689-699
    • Aminian, K.1    Najafi, B.2    Bula, C.3    Leyvraz, P.F.4    Robert, P.5
  • 16
    • 0018567799 scopus 로고
    • The impact of psychiatric intervention on patients with uncontrolled seizures
    • Williams D.T., Gold A.P., Shrout P., Shaffer D., and Adams D. The impact of psychiatric intervention on patients with uncontrolled seizures. J Nerv Ment Dis 167 (1979) 626-631
    • (1979) J Nerv Ment Dis , vol.167 , pp. 626-631
    • Williams, D.T.1    Gold, A.P.2    Shrout, P.3    Shaffer, D.4    Adams, D.5
  • 17
    • 0031849485 scopus 로고    scopus 로고
    • Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses
    • Rankin G., and Stokes M. Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil 12 (1998) 187-199
    • (1998) Clin Rehabil , vol.12 , pp. 187-199
    • Rankin, G.1    Stokes, M.2
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0030005328 scopus 로고    scopus 로고
    • Measurement error
    • Bland J.M., and Altman D.G. Measurement error. BMJ 312 (1996) 1654
    • (1996) BMJ , vol.312 , pp. 1654
    • Bland, J.M.1    Altman, D.G.2
  • 21
    • 0025322577 scopus 로고
    • Research in physical medicine and rehabilitation. Preliminary data analysis
    • Buchner D.M., and Findley T.W. Research in physical medicine and rehabilitation. Preliminary data analysis. Am J Phys Med Rehabil 69 (1990) 154-169
    • (1990) Am J Phys Med Rehabil , vol.69 , pp. 154-169
    • Buchner, D.M.1    Findley, T.W.2
  • 22
    • 2942525667 scopus 로고    scopus 로고
    • Reliability of the GAITRite walkway system for the quantification of temporo-spatial parameters of gait in young and older people
    • Menz H.B., Latt M.D., Tiedemann A., Mun San Kwan M., and Lord S.R. Reliability of the GAITRite walkway system for the quantification of temporo-spatial parameters of gait in young and older people. Gait Posture 20 (2004) 20-25
    • (2004) Gait Posture , vol.20 , pp. 20-25
    • Menz, H.B.1    Latt, M.D.2    Tiedemann, A.3    Mun San Kwan, M.4    Lord, S.R.5
  • 23
    • 37049028981 scopus 로고    scopus 로고
    • Concurrent validity and intrasession reliability of the IDEEA accelerometry system for the quantification of spatiotemporal gait parameters
    • Epub 1 March 2007
    • Maffiuletti N.A., Gorelick M., Kramers-de Quervain I., Bizzini M., Munzinger J.P., Tomasetti S., et al. Concurrent validity and intrasession reliability of the IDEEA accelerometry system for the quantification of spatiotemporal gait parameters. Gait Posture 27 1 (2008) 160-163 Epub 1 March 2007
    • (2008) Gait Posture , vol.27 , Issue.1 , pp. 160-163
    • Maffiuletti, N.A.1    Gorelick, M.2    Kramers-de Quervain, I.3    Bizzini, M.4    Munzinger, J.P.5    Tomasetti, S.6
  • 24
    • 1842632619 scopus 로고    scopus 로고
    • Interventions improve gait regularity in patients with peripheral neuropathy while walking on an irregular surface under low light
    • Richardson J.K., Thies S.B., DeMott T.K., and Ashton Miller J.A. Interventions improve gait regularity in patients with peripheral neuropathy while walking on an irregular surface under low light. J Am Geriatr Soc 52 (2004) 510-515
    • (2004) J Am Geriatr Soc , vol.52 , pp. 510-515
    • Richardson, J.K.1    Thies, S.B.2    DeMott, T.K.3    Ashton Miller, J.A.4
  • 25
    • 0034880078 scopus 로고    scopus 로고
    • Gait variability and fall risk in community-living older adults: a 1-year prospective study
    • Hausdorff J.M., Rios D.A., and Edelberg H.K. Gait variability and fall risk in community-living older adults: a 1-year prospective study. Arch Phys Med Rehabil 82 (2001) 1050-1056
    • (2001) Arch Phys Med Rehabil , vol.82 , pp. 1050-1056
    • Hausdorff, J.M.1    Rios, D.A.2    Edelberg, H.K.3
  • 26
    • 34247224276 scopus 로고    scopus 로고
    • Walking speed influences on gait cycle variability
    • Jordan K., Challis J.H., and Newell K.M. Walking speed influences on gait cycle variability. Gait Posture 26 (2007) 128-134
    • (2007) Gait Posture , vol.26 , pp. 128-134
    • Jordan, K.1    Challis, J.H.2    Newell, K.M.3
  • 27
    • 0344084396 scopus 로고    scopus 로고
    • Assessment of spatio-temporal gait parameters from trunk accelerations during human walking
    • Zijlstra W., and Hof A.L. Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. Gait Posture 18 (2003) 1-10
    • (2003) Gait Posture , vol.18 , pp. 1-10
    • Zijlstra, W.1    Hof, A.L.2
  • 28
    • 21844473021 scopus 로고    scopus 로고
    • The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers
    • Giansanti D., Maccioni G., and Macellari V. The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers. IEEE Trans Biomed Eng 52 (2005) 1271-1277
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 1271-1277
    • Giansanti, D.1    Maccioni, G.2    Macellari, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.