메뉴 건너뛰기




Volumn , Issue , 2008, Pages 1119-1122

Sensor response characteristics for UHF location of PD sources

Author keywords

Couplers; Fault location; Partial discharges; UHF

Indexed keywords

CONDITION MONITORING; ELECTRIC FAULT LOCATION; HIGH FREQUENCY TRANSFORMERS; LOCATION; POWER TRANSFORMERS; WAVEGUIDE COUPLERS;

EID: 51849124744     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CMD.2008.4580480     Document Type: Conference Paper
Times cited : (23)

References (11)
  • 1
    • 17644409075 scopus 로고    scopus 로고
    • Partial discharge monitoring for power transformers using UHF sensors Part 2: Field Experience
    • May/June
    • M D Judd, L Yang and I B B Hunter, "Partial discharge monitoring for power transformers using UHF sensors Part 2: Field Experience", IEEE Insulation Magazine, Vol. 21, No. 3, pp. 5-13, May/June 2005
    • (2005) IEEE Insulation Magazine , vol.21 , Issue.3 , pp. 5-13
    • Judd, M.D.1    Yang, L.2    Hunter, I.B.B.3
  • 2
    • 0023983411 scopus 로고
    • Diagnostic measurements at UHF in gas insulated substations
    • Pt. C, March
    • B F Hampton and R J Meats, "Diagnostic measurements at UHF in gas insulated substations", IEE Proc., Vol. 135, Pt. C, No. 2, pp. 137-144, March 1988
    • (1988) IEE Proc , vol.135 , Issue.2 , pp. 137-144
    • Hampton, B.F.1    Meats, R.J.2
  • 3
    • 0001571588 scopus 로고
    • Broadband couplers for UHF detection of partial discharge in gas insulated substations
    • May
    • M D Judd, O Farish and B F Hampton, "Broadband couplers for UHF detection of partial discharge in gas insulated substations", IEE Proc., Science, Measurement and Technology, Vol. 142, No. 3, pp. 237-243, May 1995
    • (1995) IEE Proc., Science, Measurement and Technology , vol.142 , Issue.3 , pp. 237-243
    • Judd, M.D.1    Farish, O.2    Hampton, B.F.3
  • 5
    • 51849141466 scopus 로고    scopus 로고
    • CIGRE Task Force 15/33.03.05, Partial discharge detection system for GIS: Sensitivity verification for the UHF method and the acoustic method, Electra, No. 183, pp. 74-87, April 1999
    • CIGRE Task Force 15/33.03.05, "Partial discharge detection system for GIS: Sensitivity verification for the UHF method and the acoustic method", Electra, No. 183, pp. 74-87, April 1999
  • 8
  • 9
    • 0032666908 scopus 로고    scopus 로고
    • Transient calibration of electric field sensors
    • May
    • M D Judd, "Transient calibration of electric field sensors", IEE Proc. Science, Measurement and Technology, Vol. 146, No. 3, pp. 113-116, May 1999
    • (1999) IEE Proc. Science, Measurement and Technology , vol.146 , Issue.3 , pp. 113-116
    • Judd, M.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.