메뉴 건너뛰기




Volumn , Issue , 2008, Pages 173-178

The instantaneous power factor approach for rotor cage faults diagnosis in three-phase induction motors

Author keywords

Electrical signature analysis; Fault severity factor; Instantaneous power factor; Rotor cage fault diagnosis; Squirrel cage induction motors

Indexed keywords

AC MOTORS; ELECTRIC POWER FACTOR; FAULT DETECTION; INDUSTRIAL ENGINEERING; MATHEMATICAL MODELS; MOTORS; POWER CONTROL; POWER ELECTRONICS;

EID: 51849097656     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SPEEDHAM.2008.4581170     Document Type: Conference Paper
Times cited : (16)

References (25)
  • 1
    • 0035388083 scopus 로고    scopus 로고
    • Squirrel-cage rotor options for ac induction motors
    • July/Aug
    • Bonnett, A. H. and T. Albers: Squirrel-cage rotor options for ac induction motors. IEEE Trans. on Ind. Applicat., vol. 37, no 4, July/Aug. 2001, pp. 1197-1209.
    • (2001) IEEE Trans. on Ind. Applicat , vol.37 , Issue.4 , pp. 1197-1209
    • Bonnett, A.H.1    Albers, T.2
  • 2
    • 0024111162 scopus 로고
    • Analysis of rotor failures in squirrel-cage induction motors
    • Nov/Dec
    • Bonnett, A. H. and G. C. Soukup: Analysis of rotor failures in squirrel-cage induction motors. IEEE Trans. on Ind. Applicat., vol. 24, no 6, Nov/Dec. 1988, pp. 1124-1130.
    • (1988) IEEE Trans. on Ind. Applicat , vol.24 , Issue.6 , pp. 1124-1130
    • Bonnett, A.H.1    Soukup, G.C.2
  • 3
    • 0034297416 scopus 로고    scopus 로고
    • A review of induction motors signature analysis as medium for fault detection
    • October
    • Benbouzid, M. E. H.: A review of induction motors signature analysis as medium for fault detection. IEEE Trans. on Ind. Elec., vol. 47, no 5, October 2000, pp. 984-993.
    • (2000) IEEE Trans. on Ind. Elec , vol.47 , Issue.5 , pp. 984-993
    • Benbouzid, M.E.H.1
  • 4
    • 29244467991 scopus 로고    scopus 로고
    • Condition monitoring and fault diagnosis of electrical motors - A review
    • Sept
    • Nandi, S.; Toliyat, H. A.; Li, X.: Condition monitoring and fault diagnosis of electrical motors - A review. IEEE Trans. on Energy Conversion, vol. 20, no 4, Sept. 2005, pp. 719-729.
    • (2005) IEEE Trans. on Energy Conversion , vol.20 , Issue.4 , pp. 719-729
    • Nandi, S.1    Toliyat, H.A.2    Li, X.3
  • 5
    • 33748868529 scopus 로고    scopus 로고
    • Different faults and their diagnosis techniques in three-phase squirrel-cage induction motor - A review
    • Oct
    • Faiz, J. et al: Different faults and their diagnosis techniques in three-phase squirrel-cage induction motor - A review. Electromagnetics, vol. 26, no 7, Oct. 2006, pp. 543-569.
    • (2006) Electromagnetics , vol.26 , Issue.7 , pp. 543-569
    • Faiz, J.1
  • 6
    • 33645285922 scopus 로고    scopus 로고
    • On innovative methods of induction motor interturn and broken-bar fault diagnostics
    • March/April
    • Mirafzal, B.; Demerdash, N. A. O.: On innovative methods of induction motor interturn and broken-bar fault diagnostics. IEEE Trans. on Ind. Applicat., vol. 42, no 2, March/April 2006, pp. 405-414.
    • (2006) IEEE Trans. on Ind. Applicat , vol.42 , Issue.2 , pp. 405-414
    • Mirafzal, B.1    Demerdash, N.A.O.2
  • 7
    • 0038042290 scopus 로고    scopus 로고
    • What stator current processing-based techniques to use for induction motor rotor faults diagnosis?
    • June
    • Benbouzid, M. E. H.; Kliman, G. B.: What stator current processing-based techniques to use for induction motor rotor faults diagnosis?. IEEE Trans. on Energy Conversion, vol. 18, no 2, June 2003, pp. 238-244.
    • (2003) IEEE Trans. on Energy Conversion , vol.18 , Issue.2 , pp. 238-244
    • Benbouzid, M.E.H.1    Kliman, G.B.2
  • 8
    • 0029377996 scopus 로고
    • Monitoring of defects in induction motors through air-gap torque observation
    • Sep/Oct
    • Hsu, J. H.: Monitoring of defects in induction motors through air-gap torque observation. IEEE Trans. on Ind. Applicat., vol. 31, no 5, Sep/Oct. 1995, pp. 1016-1021.
    • (1995) IEEE Trans. on Ind. Applicat , vol.31 , Issue.5 , pp. 1016-1021
    • Hsu, J.H.1
  • 9
    • 4244123245 scopus 로고    scopus 로고
    • Rotor cage faults detection in 3-phase induction motors using instantaneous power spectrum
    • Lisbon, Portugal, Sep
    • Drif, M.; Benouzza, N.; Dente, J. A.: Rotor cage faults detection in 3-phase induction motors using instantaneous power spectrum. Proc. of ELECTRIMACS' 99 Conf., Lisbon, Portugal, Sep. 1999, pp. 287-292.
    • (1999) Proc. of ELECTRIMACS' 99 Conf , pp. 287-292
    • Drif, M.1    Benouzza, N.2    Dente, J.A.3
  • 10
    • 0033316663 scopus 로고    scopus 로고
    • Cruz, S. M. A.; Cardoso, A. J. M.: Rotor cage fault diagnosis in three-phase induction motors by the total instantaneous power spectral analysis. Proc. of Conf Rec. IEEE-IAS Annu. Meeting, Arizona, USA, 1999, pp. 1929-1934.
    • Cruz, S. M. A.; Cardoso, A. J. M.: Rotor cage fault diagnosis in three-phase induction motors by the total instantaneous power spectral analysis. Proc. of Conf Rec. IEEE-IAS Annu. Meeting, Arizona, USA, 1999, pp. 1929-1934.
  • 11
    • 33749666840 scopus 로고    scopus 로고
    • A comparison of rotor fault detection techniques with respect to the assessment of fault severity
    • Atlanta, GA, USA, Aug
    • Kral, C. et al: A comparison of rotor fault detection techniques with respect to the assessment of fault severity. Proc. of SDEMPED'03 Symposium, Atlanta, GA, USA, Aug. 2003, pp. 265-270.
    • (2003) Proc. of SDEMPED'03 Symposium , pp. 265-270
    • Kral, C.1
  • 12
    • 0034297535 scopus 로고    scopus 로고
    • Comparative investigation of diagnostic media for induction motors: A case of rotor cage faults
    • Oct
    • Trzynadlowski, A. M.; Ritchie, E.: Comparative investigation of diagnostic media for induction motors: A case of rotor cage faults. IEEE Trans. on Ind. Elec., vol. 47, no 5, Oct. 2000, pp. 1092-1099.
    • (2000) IEEE Trans. on Ind. Elec , vol.47 , Issue.5 , pp. 1092-1099
    • Trzynadlowski, A.M.1    Ritchie, E.2
  • 13
    • 1342326143 scopus 로고    scopus 로고
    • A comparison of external and internal methods of signal spectral analysis for broken rotor bars detection in induction motors
    • Feb
    • Eltabach, M.; Chahata, A.; Zein, I.: A comparison of external and internal methods of signal spectral analysis for broken rotor bars detection in induction motors. IEEE Trans. on Ind. Elec., vol. 51, no 1, Feb. 2004, pp. 107-121.
    • (2004) IEEE Trans. on Ind. Elec , vol.51 , Issue.1 , pp. 107-121
    • Eltabach, M.1    Chahata, A.2    Zein, I.3
  • 14
    • 4544373211 scopus 로고    scopus 로고
    • Online rotor mixed fault diagnosis way based on spectrum analysis of instantaneous power in squirrel cage induction motors
    • Sept
    • Liu, Z.; Yin, X.; Zhang, Z.; Chen, D.: Online rotor mixed fault diagnosis way based on spectrum analysis of instantaneous power in squirrel cage induction motors. IEEE Trans. on Energy Conversion, vol. 19, no 3, Sept. 2004, pp. 485-490.
    • (2004) IEEE Trans. on Energy Conversion , vol.19 , Issue.3 , pp. 485-490
    • Liu, Z.1    Yin, X.2    Zhang, Z.3    Chen, D.4
  • 15
    • 26844504207 scopus 로고    scopus 로고
    • Rotor cage fault diagnosis in three-phase induction motors by the extended Park's vector approach
    • April
    • Cruz, S. M. A.; Cardoso, A. J. M.: Rotor cage fault diagnosis in three-phase induction motors by the extended Park's vector approach. Electric Machines and Power Systems, vol. 28, no 4, April 2000, pp. 289-299.
    • (2000) Electric Machines and Power Systems , vol.28 , Issue.4 , pp. 289-299
    • Cruz, S.M.A.1    Cardoso, A.J.M.2
  • 16
    • 35348914708 scopus 로고    scopus 로고
    • Noninvasive rotor cage fault diagnostics in three-phase induction motors using the α ,β instantaneous active power approach
    • July
    • Drif, M.; Cardoso, A. J. M.: Noninvasive rotor cage fault diagnostics in three-phase induction motors using the α ,β instantaneous active power approach. Inter. Journal of Comadem, vol. 10, no 3, July 2007, pp. 19-28.
    • (2007) Inter. Journal of Comadem , vol.10 , Issue.3 , pp. 19-28
    • Drif, M.1    Cardoso, A.J.M.2
  • 17
    • 35048826298 scopus 로고    scopus 로고
    • Rotor cage fault diagnostics in three-phase induction motors, by the instantaneous phaseangle signature analysis
    • Antalya, Turkey, May
    • Drif, M.; Cardoso, A. J. M.: Rotor cage fault diagnostics in three-phase induction motors, by the instantaneous phaseangle signature analysis. Proc. of IEMDC 2007 Conf., Antalya, Turkey, May 2007, pp. 1440-1445.
    • (2007) Proc. of IEMDC 2007 Conf , pp. 1440-1445
    • Drif, M.1    Cardoso, A.J.M.2
  • 18
    • 50049119461 scopus 로고    scopus 로고
    • Rotor cage fault diagnostics in three-phase induction motors, by the instantaneous nonactive power signature analysis
    • Vigo, Spain, June
    • Drif, M.; Cardoso, A. J. M.: Rotor cage fault diagnostics in three-phase induction motors, by the instantaneous nonactive power signature analysis. Proc. of ISIE 2007 Symposium, Vigo, Spain, June 2007, pp. 1050-1055.
    • (2007) Proc. of ISIE 2007 Symposium , pp. 1050-1055
    • Drif, M.1    Cardoso, A.J.M.2
  • 19
    • 0027576813 scopus 로고
    • New concepts of instantaneous active and reactive powers in electrical systems with generic loads
    • April
    • Watanabe, E. H.; Stephan, R. M.; Aredes, M.: New concepts of instantaneous active and reactive powers in electrical systems with generic loads. IEEE Trans. on Power Delivery, vol. 8, no 2, April 1993, pp. 697-703.
    • (1993) IEEE Trans. on Power Delivery , vol.8 , Issue.2 , pp. 697-703
    • Watanabe, E.H.1    Stephan, R.M.2    Aredes, M.3
  • 20
    • 0034476509 scopus 로고    scopus 로고
    • Comparison of time-based non-active power definitions for active filtering
    • Mexico, Oct
    • Tolbert, L. M.; Habetler, T. G.: Comparison of time-based non-active power definitions for active filtering. Proc. of CIEP'00 Conf., Mexico, Oct. 2000, pp. 73-79.
    • (2000) Proc. of CIEP'00 Conf , pp. 73-79
    • Tolbert, L.M.1    Habetler, T.G.2
  • 21
    • 0027150994 scopus 로고
    • The p-q theory in three-phase systems under non-sinusoidal conditions
    • Jan
    • Akagi, H.; Nabae, A.: The p-q theory in three-phase systems under non-sinusoidal conditions. ETEP, vol. 3, Jan. 1993, pp. 27-31.
    • (1993) ETEP , vol.3 , pp. 27-31
    • Akagi, H.1    Nabae, A.2
  • 22
    • 0026171590 scopus 로고
    • A new approach to the definition of power components in three-phase systems under nonsinusoidal conditions
    • June
    • Ferrero, A.; Superti-Furga, G.: A new approach to the definition of power components in three-phase systems under nonsinusoidal conditions. IEEE Trans. on Instr. and Meas., vol. 40, no 3, June 1991, pp. 568-577.
    • (1991) IEEE Trans. on Instr. and Meas , vol.40 , Issue.3 , pp. 568-577
    • Ferrero, A.1    Superti-Furga, G.2
  • 23
    • 0030086397 scopus 로고    scopus 로고
    • Generalized instantaneous reactive power theory for three-phase power systems
    • Feb
    • Peng, F. Z.; Lai, J.-S.: Generalized instantaneous reactive power theory for three-phase power systems. IEEE Trans. on Instr. and Meas., vol. 45, no 1, Feb. 1996, pp. 293-297.
    • (1996) IEEE Trans. on Instr. and Meas , vol.45 , Issue.1 , pp. 293-297
    • Peng, F.Z.1    Lai, J.-S.2
  • 24
    • 0029321518 scopus 로고
    • Transient analysis of cage induction machines under stator, rotor bar and end ring faults
    • June
    • Toliyat, H. A.; Lipo, T. A.: Transient analysis of cage induction machines under stator, rotor bar and end ring faults. IEEE Trans. on Energy Conversion, vol. 10, no 2, June 1995, pp. 241-247.
    • (1995) IEEE Trans. on Energy Conversion , vol.10 , Issue.2 , pp. 241-247
    • Toliyat, H.A.1    Lipo, T.A.2
  • 25


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.