메뉴 건너뛰기




Volumn 29, Issue 8, 2008, Pages 1594-1595

Rescue retrieval of AngioGuard embolic capture system after failure of capture sheath retrieval in carotid angioplasty and stenting

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOPLASTY; ARTICLE; CARDIOVASCULAR EQUIPMENT; CAROTID ARTERY OBSTRUCTION; CASE REPORT; CLINICAL FEATURE; HEART CATHETER; HUMAN; SHEATH REMOVAL; STENT; TREATMENT FAILURE; TREATMENT OUTCOME;

EID: 51649118866     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A1118     Document Type: Article
Times cited : (16)

References (5)
  • 1
    • 0025734372 scopus 로고
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators. N Engl J Med 1991;325:445-53
    • (1991) N Engl J Med , vol.325 , pp. 445-453
  • 2
    • 0028938324 scopus 로고
    • Endarterectomy for asymptomatic carotid artery stenosis. Executive Committee for the Asymptomatic Carotid Atherosclerosis Study
    • Endarterectomy for asymptomatic carotid artery stenosis. Executive Committee for the Asymptomatic Carotid Atherosclerosis Study. JAMA 1995;273:1421-28
    • (1995) JAMA , vol.273 , pp. 1421-1428
  • 3
    • 0028846114 scopus 로고
    • Emergency percutaneous carotid stenting during stroke
    • Shawl FA. Emergency percutaneous carotid stenting during stroke. Lancet 1995;346:1223
    • (1995) Lancet , vol.346 , pp. 1223
    • Shawl, F.A.1
  • 4
    • 19544385747 scopus 로고    scopus 로고
    • Protected carotid-artery stenting versus endarterectomy in high-risk patients
    • Yadav JS, Wholey MH, Kuntz RE, et al. Protected carotid-artery stenting versus endarterectomy in high-risk patients. N Engl J Med 2004;351:1493-501
    • (2004) N Engl J Med , vol.351 , pp. 1493-1501
    • Yadav, J.S.1    Wholey, M.H.2    Kuntz, R.E.3
  • 5
    • 51649092758 scopus 로고    scopus 로고
    • Cordis Corporation. Instructions for Use. AngioGuard XP Emboli Capture Guidewire System [package insert, Miami Lakes, Fla: Cordis; 2006. Available at
    • Cordis Corporation. Instructions for Use. AngioGuard XP Emboli Capture Guidewire System [package insert]. Miami Lakes, Fla: Cordis; 2006. Available at http://www.cordislabeling.com/pdf/24408544_3.pdf.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.