-
1
-
-
0000004140
-
Measurement in medicine: The analysis of method comparison studies
-
Altman, X., Bland, X. (1983). Measurement in medicine: The analysis of method comparison studies. Statisticians 32:307-317.
-
(1983)
Statisticians
, vol.32
, pp. 307-317
-
-
Altman, X.1
Bland, X.2
-
2
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland, X., Altman, X. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307-310.
-
(1986)
Lancet
, vol.8
, pp. 307-310
-
-
Bland, X.1
Altman, X.2
-
3
-
-
0032884749
-
Measuring agreement in method comparison studies
-
Bland, X., Altman, X. (1999). Measuring agreement in method comparison studies. Stat. Methods Med. Res. 8:137-160.
-
(1999)
Stat. Methods Med. Res
, vol.8
, pp. 137-160
-
-
Bland, X.1
Altman, X.2
-
4
-
-
0001700356
-
Sample size for tolerance limits on a normal distribution
-
Faulkenberry, X., Daley, X. (1970). Sample size for tolerance limits on a normal distribution. Technometrics 12(4):813-821.
-
(1970)
Technometrics
, vol.12
, Issue.4
, pp. 813-821
-
-
Faulkenberry, X.1
Daley, X.2
-
5
-
-
51649101446
-
Biostatistical aspects of transferring an analytical method to a second pharmaceutical laboratory
-
September 26-28, Potsdam, Germany
-
Fromke, C., Hothorn, L., Onken, J., Sczesny, F. (2006, September 26-28) Biostatistical aspects of transferring an analytical method to a second pharmaceutical laboratory. Presentation at Non-Clinical Statistics Conference, Potsdam, Germany.
-
(2006)
Presentation at Non-Clinical Statistics Conference
-
-
Fromke, C.1
Hothorn, L.2
Onken, J.3
Sczesny, F.4
-
6
-
-
0003446320
-
-
2nd ed. New York: John Wiley & Sons
-
Johnson, N., Kotz, X., Balakrishnan, X. (1995). Continuous Univariate Distributions. Vol. 2, 2nd ed. New York: John Wiley & Sons.
-
(1995)
Continuous Univariate Distributions
, vol.2
-
-
Johnson, N.1
Kotz, X.2
Balakrishnan, X.3
-
7
-
-
0024521543
-
A concordance correlation coefficient to evaluate reproducibility
-
Lin, L. (1989). A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255-268.
-
(1989)
Biometrics
, vol.45
, pp. 255-268
-
-
Lin, L.1
-
8
-
-
0026708519
-
Assay validation using the concordance correlation coefficient
-
Lin, L. (1992). Assay validation using the concordance correlation coefficient. Biometrics 48:599-604.
-
(1992)
Biometrics
, vol.48
, pp. 599-604
-
-
Lin, L.1
-
9
-
-
0034731817
-
Total deviation index for measuring individual agreement with applications in laboratory performance and bioequivalence
-
Lin, L. (2000). Total deviation index for measuring individual agreement with applications in laboratory performance and bioequivalence. Stat. Med. 19:255-270.
-
(2000)
Stat. Med
, vol.19
, pp. 255-270
-
-
Lin, L.1
-
10
-
-
0036489067
-
Statistical methods in assessing agreement: Models, issues, and tools
-
Lin, L., Hedayat, S., Sinha, X., Yang, X. (2002). Statistical methods in assessing agreement: Models, issues, and tools. J. Am. Stat. Assoc. 97(457):257-270.
-
(2002)
J. Am. Stat. Assoc
, vol.97
, Issue.457
, pp. 257-270
-
-
Lin, L.1
Hedayat, S.2
Sinha, X.3
Yang, X.4
-
11
-
-
0023615056
-
A comparison of the two one-sided tests procedure and the power approach for assessing the equivalence of average bioavailability
-
Schuirmann, D. (1987). A comparison of the two one-sided tests procedure and the power approach for assessing the equivalence of average bioavailability. J. Pharmacokinetic Biopharmaceutics 15:657-680.
-
(1987)
J. Pharmacokinetic Biopharmaceutics
, vol.15
, pp. 657-680
-
-
Schuirmann, D.1
-
12
-
-
1542378975
-
Assessing the agreement between two quantitative assays with repeated measurements
-
Shao, J., Zhong, B. (2004). Assessing the agreement between two quantitative assays with repeated measurements. J. Biopharm. Stat. 14:1:201-212.
-
(2004)
J. Biopharm. Stat
, vol.14
, Issue.1
, pp. 201-212
-
-
Shao, J.1
Zhong, B.2
-
13
-
-
33845799651
-
Parametric two-stage sequential quality assurance test of dose content uniformity
-
Tsong, Y., Shen, M. (2007a). Parametric two-stage sequential quality assurance test of dose content uniformity. J. Biopharm. Stat. 17:143-157.
-
(2007)
J. Biopharm. Stat
, vol.17
, pp. 143-157
-
-
Tsong, Y.1
Shen, M.2
-
14
-
-
33947216684
-
An alternative approach to assess exchangeability of a test treatment and the standard treatment with normally distributed response
-
Tsong, Y., Shen, M. (2007b). An alternative approach to assess exchangeability of a test treatment and the standard treatment with normally distributed response. J. Biopharm. Stat. 17:329-338.
-
(2007)
J. Biopharm. Stat
, vol.17
, pp. 329-338
-
-
Tsong, Y.1
Shen, M.2
-
15
-
-
4644303117
-
Three-stage sequential statistical dissolution testing rules
-
Tsong, Y., Shen, M., Shah, V. J. (2004). Three-stage sequential statistical dissolution testing rules. J. Biopharm. Stat. 14:757-779.
-
(2004)
J. Biopharm. Stat
, vol.14
, pp. 757-779
-
-
Tsong, Y.1
Shen, M.2
Shah, V.J.3
-
16
-
-
0000689040
-
Tolerance limits for a normal distribution
-
Wald, A., Wolfowitz, X. (1946). Tolerance limits for a normal distribution. Ann. Math. Stat. 19:208-215.
-
(1946)
Ann. Math. Stat
, vol.19
, pp. 208-215
-
-
Wald, A.1
Wolfowitz, X.2
-
17
-
-
0037287554
-
Evaluating the agreement of two quantitative assays with repeated measurements
-
Zhong, B., Shao, J. (2003). Evaluating the agreement of two quantitative assays with repeated measurements. J. Biopharm. Stat. 13:75-86.
-
(2003)
J. Biopharm. Stat
, vol.13
, pp. 75-86
-
-
Zhong, B.1
Shao, J.2
|