메뉴 건너뛰기




Volumn 11, Issue 4, 2008, Pages 201-207

Evaluation of left ventricular function by 64-multidetector computed tomography in patients undergoing totally endoscopic coronary artery bypass grafting

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; AUTOANALYSIS; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY OBSTRUCTION; CORRELATION ANALYSIS; ENDOSCOPIC SURGERY; EVALUATION; FEMALE; FUNCTIONAL ASSESSMENT; HEART CINEVENTRICULOGRAPHY; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE ENDSYSTOLIC VOLUME; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE VOLUME; HUMAN; IMAGE RECONSTRUCTION; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; OBSERVER VARIATION; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; REPRODUCIBILITY; ROBOTICS; SURGICAL TECHNIQUE; THREE DIMENSIONAL IMAGING; VASCULAR PATENCY; AUTOMATION; CINERADIOGRAPHY; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; ENDOSCOPY; HEART ARREST; HEART MUSCLE REVASCULARIZATION; HEART STROKE VOLUME; METHODOLOGY; MIDDLE AGED; PATHOPHYSIOLOGY; RADIOGRAPHY; STANDARD;

EID: 51649100766     PISSN: 10983511     EISSN: None     Source Type: Journal    
DOI: 10.1532/HSF98.20081046     Document Type: Article
Times cited : (6)

References (23)
  • 1
    • 32844462377 scopus 로고    scopus 로고
    • Coronary artery bypass graft (CABG) patency: Assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography
    • Anders K, Baum U, Schmid M, et al. 2006. Coronary artery bypass graft (CABG) patency: assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography. Eur J Radiol 57:336-44.
    • (2006) Eur J Radiol , vol.57 , pp. 336-344
    • Anders, K.1    Baum, U.2    Schmid, M.3
  • 2
    • 33646840820 scopus 로고    scopus 로고
    • Results of the prospective multicenter trial of robotically assisted totally endoscopic coronary artery bypass grafting
    • Argenziano M, Katz M, Bonatti J, et al. 2006. Results of the prospective multicenter trial of robotically assisted totally endoscopic coronary artery bypass grafting. Ann Thorac Surg 81:1666-74.
    • (2006) Ann Thorac Surg , vol.81 , pp. 1666-1674
    • Argenziano, M.1    Katz, M.2    Bonatti, J.3
  • 3
    • 46849085162 scopus 로고    scopus 로고
    • 1st ed. Munich, Germany. Elsevier Science Urban & Fischer. p
    • Bartel T, Müller S. 2007. Echocardiography. 1st ed. Munich, Germany. Elsevier Science Urban & Fischer. p 213-30.
    • (2007) Echocardiography , pp. 213-230
    • Bartel, T.1    Müller, S.2
  • 4
    • 33745018811 scopus 로고    scopus 로고
    • Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: Comparison with cine magnetic resonance imaging
    • Belge B, Coche E, Pasquet A, Vanoverschelde JL, Gerber BL. 2006. Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: comparison with cine magnetic resonance imaging. Eur Radiol 16:1424-33.
    • (2006) Eur Radiol , vol.16 , pp. 1424-1433
    • Belge, B.1    Coche, E.2    Pasquet, A.3    Vanoverschelde, J.L.4    Gerber, B.L.5
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing the agreement between two methods of clinical measurement
    • Bland JM, Altman DG. 1986. Statistical methods for assessing the agreement between two methods of clinical measurement. Lancet 1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. 1999. Measuring agreement in method comparison studies. Stat Methods Med Res 8:135-60.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 33846094611 scopus 로고    scopus 로고
    • Comparison of multidetector computed tomography and two-dimensional transthoracic echocardiography for left ventricular assessment in patients with heart failure
    • Buder J, Shapiro MD, Jassal D, et al. 2007. Comparison of multidetector computed tomography and two-dimensional transthoracic echocardiography for left ventricular assessment in patients with heart failure. Am J Cardiol 99:247-9.
    • (2007) Am J Cardiol , vol.99 , pp. 247-249
    • Buder, J.1    Shapiro, M.D.2    Jassal, D.3
  • 8
    • 16544371386 scopus 로고    scopus 로고
    • Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique
    • Cademartiri F, Nieman K, van der Lugt A, et al. 2004. Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233:817-23.
    • (2004) Radiology , vol.233 , pp. 817-823
    • Cademartiri, F.1    Nieman, K.2    van der Lugt, A.3
  • 9
    • 33750945800 scopus 로고    scopus 로고
    • Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography: Comparison with magnetic resonance imaging
    • Dewey M, Müller M, Eddicks S, et al. 2006. Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging. J Am Coll Cardiol 48:2034-44.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2034-2044
    • Dewey, M.1    Müller, M.2    Eddicks, S.3
  • 10
    • 20844459060 scopus 로고    scopus 로고
    • ACC/AHA 2004 guideline update for coronary artery bypass graft surgery: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1999 Guidelines for Coronary Artery Bypass Graft Surgery)
    • Eagle KA, Guyton RA, Davidoff R, et al. 2004. ACC/AHA 2004 guideline update for coronary artery bypass graft surgery: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1999 Guidelines for Coronary Artery Bypass Graft Surgery). Circulation 110:e340-437.
    • (2004) Circulation , vol.110
    • Eagle, K.A.1    Guyton, R.A.2    Davidoff, R.3
  • 11
    • 34247127374 scopus 로고    scopus 로고
    • Analysis of cardiac dimensions, mass and function in heart transplant recipients using 64-slice multi-detector computed tomography
    • Ferencik M, Gregory SA, Butler J, et al. 2007. Analysis of cardiac dimensions, mass and function in heart transplant recipients using 64-slice multi-detector computed tomography. J Heart Lung Transplant 26:478-84.
    • (2007) J Heart Lung Transplant , vol.26 , pp. 478-484
    • Ferencik, M.1    Gregory, S.A.2    Butler, J.3
  • 12
    • 34548262593 scopus 로고    scopus 로고
    • Diagnostic performance of 64-slice computed tomography for evaluation of coronary bypass grafts
    • Feuchtner GM, Schachner T, Bonatti J et al. 2007. Diagnostic performance of 64-slice computed tomography for evaluation of coronary bypass grafts. AJR Am J Roentgenol 189:574-80.
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 574-580
    • Feuchtner, G.M.1    Schachner, T.2    Bonatti, J.3
  • 13
    • 34250829612 scopus 로고    scopus 로고
    • Multislice computed tomography for preoperative and postoperative assessment in totally endoscopic coronary artery bypass grafting
    • Feuchtner G, Schachner T, Junker D, et al. 2007. Multislice computed tomography for preoperative and postoperative assessment in totally endoscopic coronary artery bypass grafting. Heart Surg Forum 10:E243-7.
    • (2007) Heart Surg Forum , vol.10
    • Feuchtner, G.1    Schachner, T.2    Junker, D.3
  • 14
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates
    • Hausleiter J, Meyer T, Hadamitzky M, et al. 2006. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113:1305-10.
    • (2006) Circulation , vol.113 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3
  • 15
    • 33749061448 scopus 로고    scopus 로고
    • Hendel RC, Patel MR, Kramer CM, et al. 2006. ACCF/ACR/SCCT/SCMR/ASNC/ NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol 48:1475-97.
    • Hendel RC, Patel MR, Kramer CM, et al. 2006. ACCF/ACR/SCCT/SCMR/ASNC/ NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol 48:1475-97.
  • 16
    • 33846427746 scopus 로고    scopus 로고
    • Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction
    • Jenkins C, Bricknell K, Chan J, Hanekom L, Marwick TH. 2007. Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction. Am J Cardiol 99:300-6.
    • (2007) Am J Cardiol , vol.99 , pp. 300-306
    • Jenkins, C.1    Bricknell, K.2    Chan, J.3    Hanekom, L.4    Marwick, T.H.5
  • 17
    • 17044382603 scopus 로고    scopus 로고
    • Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction
    • Mahnken AH, Koos R, Katoh M, et al. 2005. Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction. Eur Radiol 15:714-20.
    • (2005) Eur Radiol , vol.15 , pp. 714-720
    • Mahnken, A.H.1    Koos, R.2    Katoh, M.3
  • 18
    • 8744242132 scopus 로고    scopus 로고
    • Evaluation of venous and arterial conduit patency by 16-slice spiral computed tomography
    • Martuscelli E, Romagnoli A, D'Eliseo A, et al. 2004. Evaluation of venous and arterial conduit patency by 16-slice spiral computed tomography. Circulation 110:3234-8.
    • (2004) Circulation , vol.110 , pp. 3234-3238
    • Martuscelli, E.1    Romagnoli, A.2    D'Eliseo, A.3
  • 19
    • 33645762984 scopus 로고    scopus 로고
    • Global left ventricular function in cardiac CT: Evaluation of an automated 3D region-growing segmentation algorithm
    • Mühlenbruch G, Das M, Hohl C, et al. 2006. Global left ventricular function in cardiac CT: evaluation of an automated 3D region-growing segmentation algorithm. Eur Radiol 16:1117-23.
    • (2006) Eur Radiol , vol.16 , pp. 1117-1123
    • Mühlenbruch, G.1    Das, M.2    Hohl, C.3
  • 20
    • 33947303100 scopus 로고    scopus 로고
    • Evaluation of robotic coronary surgery with intraoperative graft angiography and multislice computed tomography
    • Schachner T, Feuchtner G, Bonatti J, et al. 2007. Evaluation of robotic coronary surgery with intraoperative graft angiography and multislice computed tomography. Ann Thorac Surg 83:1361-7.
    • (2007) Ann Thorac Surg , vol.83 , pp. 1361-1367
    • Schachner, T.1    Feuchtner, G.2    Bonatti, J.3
  • 21
    • 0026076053 scopus 로고
    • Two-dimensional echocardiographic determination of left ventricular volume, systolic function, and mass: Summary and discussion of the 1989 recommendations of the American Society of Echocardiography
    • Schiller NB. 1991. Two-dimensional echocardiographic determination of left ventricular volume, systolic function, and mass: summary and discussion of the 1989 recommendations of the American Society of Echocardiography. Circulation 84(3 Suppl):I280-7.
    • (1991) Circulation , vol.84 , Issue.3 SUPPL.
    • Schiller, N.B.1
  • 22
    • 33847265364 scopus 로고    scopus 로고
    • Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-detector-row CT: Comparison to magnetic resonance imaging
    • Schlosser T, Mohrs OK, Magedanz A, Voigtländer T, Schmermund A, Barkhausen J. 2007. Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-detector-row CT: comparison to magnetic resonance imaging. Acta Radiol 48:30-5.
    • (2007) Acta Radiol , vol.48 , pp. 30-35
    • Schlosser, T.1    Mohrs, O.K.2    Magedanz, A.3    Voigtländer, T.4    Schmermund, A.5    Barkhausen, J.6
  • 23
    • 37849043103 scopus 로고    scopus 로고
    • Left ventricular functional analysis using 64-slice multidetector row computed tomography: Comparison with left ventriculography and cardiovascular magnetic resonance
    • Wu YW, Tadamura E, Kanao S, et al. 2007. Left ventricular functional analysis using 64-slice multidetector row computed tomography: comparison with left ventriculography and cardiovascular magnetic resonance. Cardiology 109:135-42.
    • (2007) Cardiology , vol.109 , pp. 135-142
    • Wu, Y.W.1    Tadamura, E.2    Kanao, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.