메뉴 건너뛰기




Volumn 15, Issue 10, 2008, Pages 1227-1233

Accurate Automatic Papillary Muscle Identification for Quantitative Left Ventricle Mass Measurements in Cardiac Magnetic Resonance Imaging

Author keywords

left ventricular mass; Magnetic resonance imaging; papillary muscle

Indexed keywords

ARTICLE; HEART LEFT VENTRICLE MASS; HEART PAPILLARY MUSCLE; HUMAN; MUSCLE MASS; NONHUMAN; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 51449088279     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2008.04.014     Document Type: Article
Times cited : (16)

References (16)
  • 1
    • 0023720985 scopus 로고
    • Estimation of human myocardial mass with MR imaging
    • Katz J., Milliken M.C., Stray-Gundersen J., et al. Estimation of human myocardial mass with MR imaging. Radiology 169 (1988) 495-498
    • (1988) Radiology , vol.169 , pp. 495-498
    • Katz, J.1    Milliken, M.C.2    Stray-Gundersen, J.3
  • 2
    • 0022588302 scopus 로고
    • Ejection fraction determination by MR imaging: Comparison with left ventricular angiography
    • Stratemeier E.J., Thompson R., Brady T.J., et al. Ejection fraction determination by MR imaging: Comparison with left ventricular angiography. Radiology 158 (1986) 775-777
    • (1986) Radiology , vol.158 , pp. 775-777
    • Stratemeier, E.J.1    Thompson, R.2    Brady, T.J.3
  • 3
    • 0025303907 scopus 로고
    • Normal left ventricular dimensions and function: Interstudy reproducibility of measurements with cine MR imaging
    • Semelka R.C., Tomei E., Wagner S., et al. Normal left ventricular dimensions and function: Interstudy reproducibility of measurements with cine MR imaging. Radiology 174 (1990) 763-768
    • (1990) Radiology , vol.174 , pp. 763-768
    • Semelka, R.C.1    Tomei, E.2    Wagner, S.3
  • 4
    • 0025360257 scopus 로고
    • Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle
    • Semelka R.C., Tomei E., Wagner S., et al. Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle. Am Heart J 119 (1990) 1367-1373
    • (1990) Am Heart J , vol.119 , pp. 1367-1373
    • Semelka, R.C.1    Tomei, E.2    Wagner, S.3
  • 5
    • 0030987982 scopus 로고    scopus 로고
    • Global cardiac function using fast breath-hold MRI: Validation of new acquisition and analysis techniques
    • Bloomgarden D.C., Fayad Z.A., Ferrari V.A., Chin B., Sutton M.G., and Axel L. Global cardiac function using fast breath-hold MRI: Validation of new acquisition and analysis techniques. Magn Reson Med 37 (1997) 683-692
    • (1997) Magn Reson Med , vol.37 , pp. 683-692
    • Bloomgarden, D.C.1    Fayad, Z.A.2    Ferrari, V.A.3    Chin, B.4    Sutton, M.G.5    Axel, L.6
  • 6
    • 0033301605 scopus 로고    scopus 로고
    • Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging
    • Lorenz C.H., Walker E.S., Morgan V.L., Klein S.S., and Graham Jr. T.P. Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging. J Cardiovasc Magn Reson 1 (1999) 7-21
    • (1999) J Cardiovasc Magn Reson , vol.1 , pp. 7-21
    • Lorenz, C.H.1    Walker, E.S.2    Morgan, V.L.3    Klein, S.S.4    Graham Jr., T.P.5
  • 7
    • 0036104746 scopus 로고    scopus 로고
    • Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    • Moon J.C., Lorenz C.H., Francis J.M., Smith G.C., and Pennell D.J. Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility. Radiology 223 (2002) 789-797
    • (2002) Radiology , vol.223 , pp. 789-797
    • Moon, J.C.1    Lorenz, C.H.2    Francis, J.M.3    Smith, G.C.4    Pennell, D.J.5
  • 8
    • 33745127684 scopus 로고    scopus 로고
    • Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection
    • van Geuns R.J., Baks T., Gronenschild E.H., et al. Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection. Radiology 240 (2006) 215-221
    • (2006) Radiology , vol.240 , pp. 215-221
    • van Geuns, R.J.1    Baks, T.2    Gronenschild, E.H.3
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0031459542 scopus 로고    scopus 로고
    • Comparison between manual and semiautomated analysis of left ventricular volume parameters from short-axis MR images
    • van der Geest R.J., Buller V.G., Jansen E., et al. Comparison between manual and semiautomated analysis of left ventricular volume parameters from short-axis MR images. J Comput Assist Tomogr 21 (1997) 756-765
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 756-765
    • van der Geest, R.J.1    Buller, V.G.2    Jansen, E.3
  • 11
    • 1542373642 scopus 로고    scopus 로고
    • Impact of papillary muscles in ventricular volume and ejection fraction assessment by cardiovascular magnetic resonance
    • Sievers B., Kirchberg S., Bakan A., Franken U., and Trappe H.J. Impact of papillary muscles in ventricular volume and ejection fraction assessment by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 6 (2004) 9-16
    • (2004) J Cardiovasc Magn Reson , vol.6 , pp. 9-16
    • Sievers, B.1    Kirchberg, S.2    Bakan, A.3    Franken, U.4    Trappe, H.J.5
  • 12
    • 1642499216 scopus 로고    scopus 로고
    • Left ventricular mass: Manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs
    • Francois C.J., Fieno D.S., Shors S.M., and Finn J.P. Left ventricular mass: Manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs. Radiology 230 (2004) 389-395
    • (2004) Radiology , vol.230 , pp. 389-395
    • Francois, C.J.1    Fieno, D.S.2    Shors, S.M.3    Finn, J.P.4
  • 13
    • 33745276499 scopus 로고    scopus 로고
    • Left ventricular papillary muscle mass: Relationship to left ventricular mass and volumes by magnetic resonance imaging
    • Vogel-Claussen J., Finn J.P., Gomes A.S., et al. Left ventricular papillary muscle mass: Relationship to left ventricular mass and volumes by magnetic resonance imaging. J Comput Assist Tomogr 30 (2006) 426-432
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 426-432
    • Vogel-Claussen, J.1    Finn, J.P.2    Gomes, A.S.3
  • 14
    • 0027131175 scopus 로고
    • Evaluation of left ventricular mass: Comparison of ultrafast computed tomography, magnetic resonance imaging, and contrast left ventriculography
    • Yamaoka O., Yabe T., Okada M., et al. Evaluation of left ventricular mass: Comparison of ultrafast computed tomography, magnetic resonance imaging, and contrast left ventriculography. Am Heart J 126 (1993) 1372-1379
    • (1993) Am Heart J , vol.126 , pp. 1372-1379
    • Yamaoka, O.1    Yabe, T.2    Okada, M.3
  • 15
    • 43049160749 scopus 로고    scopus 로고
    • Left ventricular papillary muscles and trabeculae are significant determinants of cardiac MRI volumetric measurements: Effects on clinical standards in patients with advanced systolic dysfunction
    • Weinsaft J.W., Cham M.D., Janik M., et al. Left ventricular papillary muscles and trabeculae are significant determinants of cardiac MRI volumetric measurements: Effects on clinical standards in patients with advanced systolic dysfunction. Int J Cardiol 126 (2007) 359-365
    • (2007) Int J Cardiol , vol.126 , pp. 359-365
    • Weinsaft, J.W.1    Cham, M.D.2    Janik, M.3
  • 16
    • 20744453356 scopus 로고    scopus 로고
    • Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging
    • Papavassiliu T., Kuhl H.P., Schroder M., et al. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology 236 (2005) 57-64
    • (2005) Radiology , vol.236 , pp. 57-64
    • Papavassiliu, T.1    Kuhl, H.P.2    Schroder, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.