메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1268-1272

Study on frequency spectra of partial discharge according to defects and couplers

Author keywords

Couplers; Defects; Partial discharge; Spectrum

Indexed keywords

ARSENIC COMPOUNDS; DEFECTS; DISCHARGE (FLUID MECHANICS); ELECTRIC DISCHARGES; ELECTRIC MACHINE INSULATION; GEOGRAPHIC INFORMATION SYSTEMS; INSULATING MATERIALS; RUNOFF; SURFACE DISCHARGES; WATER POLLUTION;

EID: 51349146062     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 2
    • 51349118976 scopus 로고    scopus 로고
    • UHF Partial Discharge Measurement Technology using a Dual Bands Methods to have the Frequency Characteristics in GIS
    • Mar
    • K. H. Kim, S. H. Yi, J. H. Sun, D. S. Kang, "UHF Partial Discharge Measurement Technology using a Dual Bands Methods to have the Frequency Characteristics in GIS", Trans. KIEE, Vol. 55C, No. 3, pp. 127-133, Mar. 2006.
    • (2006) Trans. KIEE , vol.55 C , Issue.3 , pp. 127-133
    • Kim, K.H.1    Yi, S.H.2    Sun, J.H.3    Kang, D.S.4
  • 3
    • 51349154067 scopus 로고    scopus 로고
    • The Detection Characteristics of the Partial Discharge Pluses with Folded Dipole Type Sensors in the Oil Transformers
    • Oct
    • K. H. Kim, S, H. Yi, J. H. Sun, D. S. Kang, J. C. Kim, "The Detection Characteristics of the Partial Discharge Pluses with Folded Dipole Type Sensors in the Oil Transformers" Trans. KJEE, Vol. 55C, No. 10, pp. 485-491, Oct.. 2006.
    • (2006) Trans. KJEE , vol.55 C , Issue.10 , pp. 485-491
    • Kim, K.H.1    Yi, S.H.2    Sun, J.H.3    Kang, D.S.4    Kim, J.C.5
  • 4
    • 0026172832 scopus 로고
    • A continuous uhf monitor for gas-insulated substation
    • June
    • J. S. Pearson, B. F. Hampton and A. G. Sellars, "A continuous uhf monitor for gas-insulated substation", IEEE trans Electrical Insulation Vol. 26 No. 3, pp 469-478, June, 1991
    • (1991) IEEE trans Electrical Insulation , vol.26 , Issue.3 , pp. 469-478
    • Pearson, J.S.1    Hampton, B.F.2    Sellars, A.G.3
  • 5
    • 33748297359 scopus 로고    scopus 로고
    • Discrimination of streamer/leader type partial discharge in SF6 gas based discharge mechanism
    • Plenum Press
    • H. Okubo, T. Takahashi, T. Yamada and M. Hikita, "Discrimination of streamer/leader type partial discharge in SF6 gas based discharge mechanism", Gaseous Dielectrics VIII, Plenum Press, 1998, pp 269-274.
    • (1998) Gaseous Dielectrics VIII , pp. 269-274
    • Okubo, H.1    Takahashi, T.2    Yamada, T.3    Hikita, M.4
  • 6
    • 0033702402 scopus 로고    scopus 로고
    • Sander Meijer, Andrea Bovis, Edward Gluski, John J. Smit and Alian Girodet, Analysis of the sensitivity of the uhf PD measuring technique, Conference Record of 2000 IEEE international Symposium on Electrical Insulation, April 2000, pp 395-399
    • Sander Meijer, Andrea Bovis, Edward Gluski, John J. Smit and Alian Girodet, "Analysis of the sensitivity of the uhf PD measuring technique", Conference Record of 2000 IEEE international Symposium on Electrical Insulation, April 2000, pp 395-399
  • 7
    • 84960412468 scopus 로고    scopus 로고
    • R. Feger, K. Feser, C. Neumann, V. Rees, Non-conventional uhf sensors for PD measurements on GIS of different design, Conference Record of 2000 IEEE international Symposium on Electrical Insulation, April 2000, pp 1395-1400
    • R. Feger, K. Feser, C. Neumann, V. Rees, "Non-conventional uhf sensors for PD measurements on GIS of different design", Conference Record of 2000 IEEE international Symposium on Electrical Insulation, April 2000, pp 1395-1400
  • 8
    • 51349083516 scopus 로고    scopus 로고
    • M. Knapp, R. Feger, K. Feser, Application of the CIGRE-Sensitivity verification for UHF PD detection in Three-Phase GIS, High Voltage Engineering Symposium, August 1999, 5
    • M. Knapp, R. Feger, K. Feser, "Application of the CIGRE-Sensitivity verification for UHF PD detection in Three-Phase GIS", High Voltage Engineering Symposium, August 1999, 5
  • 9
    • 0032121529 scopus 로고    scopus 로고
    • Partial discharge measurement in a long distance SF6 gas insulated transmission line(GIL)
    • July
    • H. Okubo, M. Yoshida, T. Takahashi, T. Hoshino, "Partial discharge measurement in a long distance SF6 gas insulated transmission line(GIL)", IEEE Trans. Power Deliverly Vol. 13, No. 3 July 1998, pp. 683-690
    • (1998) IEEE Trans. Power Deliverly , vol.13 , Issue.3 , pp. 683-690
    • Okubo, H.1    Yoshida, M.2    Takahashi, T.3    Hoshino, T.4
  • 10
    • 0029710592 scopus 로고    scopus 로고
    • Christophe Moreau, Xavier Charpentier, On-Line Partial Discharge Detection System for Instrument Transformers, 1996 IEEE International Symposium on Electrical Insulation, June 1996, pp 65-68
    • Christophe Moreau, Xavier Charpentier, "On-Line Partial Discharge Detection System for Instrument Transformers", 1996 IEEE International Symposium on Electrical Insulation, June 1996, pp 65-68


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.