Volumn , Issue , 2008, Pages 969-973

Studies of the accuracy of clamp-on transit time ultrasonic flowmeters

Author keywords

Clamp on; Flow measurement; Flowmeter; Ray model; Ultrasonic

Indexed keywords

COMPUTER NETWORKS; FLOW MEASUREMENT; FLOWMETERS; INSTRUMENTS; MEASUREMENT THEORY; SEPARATION; ULTRASONICS;

EID: 51349130920     PISSN: 10915281     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IMTC.2008.4547177     Document Type: Conference Paper
Times cited : (18)

References (7)
  • 1
    • 0036705145 scopus 로고    scopus 로고
    • Guidelines for the use of ultrasonic non-invasive metering techniques
    • August, pages
    • Sanderson, M. L. and Yeung, H (2002). "Guidelines for the use of ultrasonic non-invasive metering techniques.", Flow Measurement and Instrumentation, Volume 13, Number 4, August 2002, pages: 125-142
    • (2002) Flow Measurement and Instrumentation , vol.13 , Issue.4 , pp. 125-142
    • Sanderson, M.L.1    Yeung, H.2
  • 2
    • 33845719424 scopus 로고    scopus 로고
    • Ultrasonic flowmeters: Half-century progress report, 1955-2005
    • pages
    • Lynnworth, L. C. and Liu, Y. (2006). Ultrasonic flowmeters: Half-century progress report, 1955-2005., Ultrasonics, 2006, pages: 1372-1378.
    • (2006) Ultrasonics, 2006 , pp. 1372-1378
    • Lynnworth, L.C.1    Liu, Y.2
  • 4
    • 0030189829 scopus 로고    scopus 로고
    • Acoustic Transfer function of the clamp-on flowmeter, Ultrasonics
    • July ,pages
    • Funck, B and Mitzkus, A. (1996). Acoustic Transfer function of the clamp-on flowmeter, Ultrasonics, Ferroelectrics and Frequency Control, July 1996,Volume: 43, Issue: 4, pages:569-575
    • (1996) Ferroelectrics and Frequency Control , vol.43 , Issue.4 , pp. 569-575
    • Funck, B.1    Mitzkus, A.2
  • 5
    • 33645894977 scopus 로고    scopus 로고
    • Observations on the design and development of a water flow rig related to calibration in the manufacturing process
    • Baker, R. C., Wang, T., Moore, P. I. and Nurse, A. (2006) Observations on the design and development of a water flow rig related to calibration in the manufacturing process, Journal of Flow Measurement and Instrumentation, 17:171-8.
    • (2006) Journal of Flow Measurement and Instrumentation , vol.17 , pp. 171-178
    • Baker, R.C.1    Wang, T.2    Moore, P.I.3    Nurse, A.4
  • 6
    • 51349110704 scopus 로고    scopus 로고
    • Further observations on the performance of a water flow rig related to calibration in the manufacturing process
    • to be submitted
    • Shimada, T, Mahadeva, D. V. and Baker, R. C. (2008) Further observations on the performance of a water flow rig related to calibration in the manufacturing process, to be submitted
    • (2008)
    • Shimada, T.1    Mahadeva, D.V.2    Baker, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.