메뉴 건너뛰기




Volumn 97, Issue 9, 2008, Pages 565-574

Real-time transesophageal three-dimensional echocardiography for guidance of percutaneous cardiac interventions: First experience

Author keywords

Percutaneous cardiac interventions; Three dimensional echocardiography; Transesophageal echocardiography

Indexed keywords

AORTA VALVE REPLACEMENT; COMORBIDITY; CORONARY SINUS; FLUOROSCOPY; HEART ATRIUM SEPTUM DEFECT; HEART CATHETER; HEART HEMODYNAMICS; HEART SURGERY; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; MITRAL ANNULOPLASTY; MITRAL VALVE REGURGITATION; MORBIDITY; MORTALITY; PATENT FORAMEN OVALE; PREVALENCE; PROSTHESIS; REVIEW; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 51349125172     PISSN: 18610684     EISSN: 18610692     Source Type: Journal    
DOI: 10.1007/s00392-008-0676-3     Document Type: Review
Times cited : (69)

References (28)
  • 1
    • 46449117701 scopus 로고    scopus 로고
    • Real-time three-dimensional transesophageal echocardiography for guidance of atrial septal defect closures
    • DOI 10.1093/eurhearj/ehn115
    • Balzer J, Kühl H, Frankc A (2008) Real-time three-dimensional transesophageal echocardiography for guidance of atrial septal defect closures. Eur Heart J DOI 10.1093/eurhearj/ehn115
    • (2008) Eur Heart J
    • Balzer, J.1    Kühl, H.2    Frankc, A.3
  • 2
    • 0032846406 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): Multicentre UK experience
    • KC Chan MJ Godman K Walsh N Wilson A Redington JL Gibbs 1999 Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience Heart 82 300 306
    • (1999) Heart , vol.82 , pp. 300-306
    • Chan, K.C.1    Godman, M.J.2    Walsh, K.3    Wilson, N.4    Redington, A.5    Gibbs, J.L.6
  • 3
    • 24044500609 scopus 로고    scopus 로고
    • Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images
    • C Corsi RM Lang F Veronesi L Weinert EG Caiani P MacEneaney C Lamberti V Mor-Avi 2005 Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images Circulation 112 1161 1170
    • (2005) Circulation , vol.112 , pp. 1161-1170
    • Corsi, C.1    Lang, R.M.2    Veronesi, F.3    Weinert, L.4    Caiani, E.G.5    MacEneaney, P.6    Lamberti, C.7    Mor-Avi, V.8
  • 5
    • 18244393190 scopus 로고    scopus 로고
    • Percutaneous mitral valve repair for chronic ischemic mitral regurgitation: A real-time three-dimensional echocardiographic study in an ovine model
    • M Daimon T Shiota AM Gillinov M Hayase M Ruel WE Cohn SJ Blacker JR Liddicoat 2005 Percutaneous mitral valve repair for chronic ischemic mitral regurgitation: a real-time three-dimensional echocardiographic study in an ovine model Circulation 111 2183 2189
    • (2005) Circulation , vol.111 , pp. 2183-2189
    • Daimon, M.1    Shiota, T.2    Gillinov, A.M.3    Hayase, M.4    Ruel, M.5    Cohn, W.E.6    Blacker, S.J.7    Liddicoat, J.R.8
  • 8
    • 0030901476 scopus 로고    scopus 로고
    • A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. in vitro and in vivo accuracy results
    • L Gepstein G Hayam SA Ben-Haim 1997 A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results Circulation 95 1611 1622
    • (1997) Circulation , vol.95 , pp. 1611-1622
    • Gepstein, L.1    Hayam, G.2    Ben-Haim, S.A.3
  • 9
    • 33845370920 scopus 로고    scopus 로고
    • Pulmonary regurgitation is a powerful factor influencing QRS duration in patients after surgical repair of tetralogy of Fallot. a magnetic resonance imaging (MRI) study
    • M Grothoff B Spors H Abdul-Khaliq M Abd El Rahman V Alexi-Meskishvili P Lange R Felix M Gutberlet 2006 Pulmonary regurgitation is a powerful factor influencing QRS duration in patients after surgical repair of tetralogy of Fallot. A magnetic resonance imaging (MRI) study Clin Res Cardiol 95 643 649
    • (2006) Clin Res Cardiol , vol.95 , pp. 643-649
    • Grothoff, M.1    Spors, B.2    Abdul-Khaliq, H.3    Abd El Rahman, M.4    Alexi-Meskishvili, V.5    Lange, P.6    Felix, R.7    Gutberlet, M.8
  • 11
    • 33644692644 scopus 로고    scopus 로고
    • A hybrid approach for quantification of aortic valve stenosis using cardiac magnetic resonance imaging and echocardiography: Comparison to right heart catheterization and standard echocardiography
    • D Haghi T Suselbeck S Fluechter G Kalmar M Schroder JJ Kaden T Poerner M Borggrefe T Papavassiliu 2006 A hybrid approach for quantification of aortic valve stenosis using cardiac magnetic resonance imaging and echocardiography: comparison to right heart catheterization and standard echocardiography Clin Res Cardiol 95 162 167
    • (2006) Clin Res Cardiol , vol.95 , pp. 162-167
    • Haghi, D.1    Suselbeck, T.2    Fluechter, S.3    Kalmar, G.4    Schroder, M.5    Kaden, J.J.6    Poerner, T.7    Borggrefe, M.8    Papavassiliu, T.9
  • 13
  • 16
    • 17144461250 scopus 로고    scopus 로고
    • High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging
    • HP Kühl M Schreckenberg D Rulands M Katoh W Schäfer G Schummers A Bücker P Hanrath A Franke 2004 High-resolution transthoracic real-time three-dimensional echocardiography: quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging J Am Coll Cardiol 43 2083 2090
    • (2004) J Am Coll Cardiol , vol.43 , pp. 2083-2090
    • Kühl, H.P.1    Schreckenberg, M.2    Rulands, D.3    Katoh, M.4    Schäfer, W.5    Schummers, G.6    Bücker, A.7    Hanrath, P.8    Franke, A.9
  • 24
    • 7944225797 scopus 로고    scopus 로고
    • Usefulness of three-dimensional echocardiographic reconstruction of the Amplatzer septal occluder in patients undergoing atrial septal closure
    • M Pepi G Tamborini AL Bartorelli D Trabattoni A Maltagliati S De Vita D Andreini G Pontone 2004 Usefulness of three-dimensional echocardiographic reconstruction of the Amplatzer septal occluder in patients undergoing atrial septal closure Am J Cardiol 94 1343 1347
    • (2004) Am J Cardiol , vol.94 , pp. 1343-1347
    • Pepi, M.1    Tamborini, G.2    Bartorelli, A.L.3    Trabattoni, D.4    Maltagliati, A.5    De Vita, S.6    Andreini, D.7    Pontone, G.8
  • 25
    • 37349014018 scopus 로고    scopus 로고
    • Real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology: Feasibility study
    • EC Pua SF Idriss PD Wolf SW Smith 2007 Real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology: feasibility study Ultrason Imaging 29 182 194
    • (2007) Ultrason Imaging , vol.29 , pp. 182-194
    • Pua, E.C.1    Idriss, S.F.2    Wolf, P.D.3    Smith, S.W.4
  • 26
    • 13244293452 scopus 로고    scopus 로고
    • Real-time subcostal 3-dimensional echocardiography for guided percutaneous atrial septal defect closure
    • KS Roman M Nii F Golding LN Benson JF Smallhorn 2004 Real-time subcostal 3-dimensional echocardiography for guided percutaneous atrial septal defect closure Circulation 109 320 321
    • (2004) Circulation , vol.109 , pp. 320-321
    • Roman, K.S.1    Nii, M.2    Golding, F.3    Benson, L.N.4    Smallhorn, J.F.5
  • 27
    • 34250841142 scopus 로고    scopus 로고
    • Live 3-dimensional echocardiography guidance for the insertion of a retrograde cardioplegic catheter through the coronary sinus
    • Y Suematsu B Kiaii D Bainbridge RJ Novick 2007 Live 3-dimensional echocardiography guidance for the insertion of a retrograde cardioplegic catheter through the coronary sinus Heart Surg Forum 10 E188 E190
    • (2007) Heart Surg Forum , vol.10
    • Suematsu, Y.1    Kiaii, B.2    Bainbridge, D.3    Novick, R.J.4
  • 28
    • 33747431187 scopus 로고    scopus 로고
    • Quantitative assessment of left ventricular size and function: Side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference
    • L Sugeng V Mor-Avi L Weinert J Niel C Ebner R Steringer-Mascherbauer F Schmidt C Galuschky G Schummers RM Lang HJ Nesser 2006 Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference Circulation 114 654 661
    • (2006) Circulation , vol.114 , pp. 654-661
    • Sugeng, L.1    Mor-Avi, V.2    Weinert, L.3    Niel, J.4    Ebner, C.5    Steringer-Mascherbauer, R.6    Schmidt, F.7    Galuschky, C.8    Schummers, G.9    Lang, R.M.10    Nesser, H.J.11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.