메뉴 건너뛰기




Volumn 47, Issue 6, 2008, Pages 1077-1086

In-beam PET measurements of biological half-lives of 12C irradiation induced β+-activity

Author keywords

[No Author keywords available]

Indexed keywords

CARBON;

EID: 51149093939     PISSN: 0284186X     EISSN: 1651226X     Source Type: Journal    
DOI: 10.1080/02841860701769743     Document Type: Article
Times cited : (48)

References (20)
  • 1
    • 0033606589 scopus 로고    scopus 로고
    • Positron emission tomography for quality assurance of cancer therapy with light ion beams
    • Enghardt W, Debus J, Haberer T, Hasch BG, Hinz R, Jäkel O, et al. Positron emission tomography for quality assurance of cancer therapy with light ion beams. Nucl Phys A 1999;654:1047c-50c.
    • (1999) Nucl Phys A , vol.654
    • Enghardt, W.1    Debus, J.2    Haberer, T.3    Hasch, B.G.4    Hinz, R.5    Jäkel, O.6
  • 4
    • 11044221998 scopus 로고    scopus 로고
    • The modelling of positron emitter production and PET imaging during carbon ion therapy
    • Pönisch F, Parodi K, Hasch BG, Enghardt W. The modelling of positron emitter production and PET imaging during carbon ion therapy. Phys Med Biol 2004;49:5217-32.
    • (2004) Phys Med Biol , vol.49 , pp. 5217-5232
    • Pönisch, F.1    Parodi, K.2    Hasch, B.G.3    Enghardt, W.4
  • 5
    • 0042476344 scopus 로고    scopus 로고
    • Attenuation and scatter correction for in-beam positron emission tomography monitoring of tumour irradiations with heavy ion beams
    • Pönisch F, Enghardt W, Lauckner K. Attenuation and scatter correction for in-beam positron emission tomography monitoring of tumour irradiations with heavy ion beams. Phys Med Biol 2003;48:2419-36.
    • (2003) Phys Med Biol , vol.48 , pp. 2419-2436
    • Pönisch, F.1    Enghardt, W.2    Lauckner, K.3
  • 6
    • 51149083775 scopus 로고    scopus 로고
    • Optimization of in-beam positron emission tomography for monitoring heavy ion tumor therapy
    • Crespo P. Optimization of in-beam positron emission tomography for monitoring heavy ion tumor therapy. Wiss-Tech Berichte FZR 2005;444.
    • (2005) Wiss-Tech Berichte FZR , pp. 444
    • Crespo, P.1
  • 7
    • 33645990582 scopus 로고    scopus 로고
    • On the detector arrangement for in-beam PET for hadron therapy monitoring
    • Crespo P, Shakirin G, Enghardt W. On the detector arrangement for in-beam PET for hadron therapy monitoring. Phys Med Biol 2006;51:2143-63.
    • (2006) Phys Med Biol , vol.51 , pp. 2143-2163
    • Crespo, P.1    Shakirin, G.2    Enghardt, W.3
  • 8
    • 51149087991 scopus 로고    scopus 로고
    • 11C atoms induced by irradiation of water and aqueous solutions with 185 MeV protons. Ph.D. Thesis, Uppsala:1970.
    • 11C atoms induced by irradiation of water and aqueous solutions with 185 MeV protons. Ph.D. Thesis, Uppsala:1970.
  • 10
    • 10744227644 scopus 로고    scopus 로고
    • Washout measurement of radioisotope implanted by radioactive beams in the rabbit
    • Mizuno H, Tomitani T, Kanazawa M, Kitagawa A, Pawelke J, Iseki Y, et al. Washout measurement of radioisotope implanted by radioactive beams in the rabbit. Phys Med Biol 2003;48:2269-81.
    • (2003) Phys Med Biol , vol.48 , pp. 2269-2281
    • Mizuno, H.1    Tomitani, T.2    Kanazawa, M.3    Kitagawa, A.4    Pawelke, J.5    Iseki, Y.6
  • 11
    • 51149104684 scopus 로고    scopus 로고
    • Beiträge zur Einführung der Positronen-Emissions- Tomographie bei der Schwerionen-Tumortherapie. Wiss.-Tech. Berichte FZR
    • Hinz R. Beiträge zur Einführung der Positronen-Emissions- Tomographie bei der Schwerionen-Tumortherapie. Wiss.-Tech. Berichte FZR 2000;286.
    • (2000) , pp. 286
    • Hinz, R.1
  • 12
    • 51149088201 scopus 로고    scopus 로고
    • The evaluation of carbon ion therapy PET data within the time domain
    • Kausch C, Enghardt W. The evaluation of carbon ion therapy PET data within the time domain. GSI Annual Report 2002;176.
    • GSI Annual Report 2002 , vol.176
    • Kausch, C.1    Enghardt, W.2
  • 13
    • 19044397899 scopus 로고    scopus 로고
    • Random coincidences during in-beam PET measurements at microbunched therapeutic ion beams
    • Parodi K, Crespo P, Eickhoff H, Haberer T, Pawelke J, Schardt D, et al. Random coincidences during in-beam PET measurements at microbunched therapeutic ion beams. Nucl Instr Meth A 2005;545:446-58.
    • (2005) Nucl Instr Meth A , vol.545 , pp. 446-458
    • Parodi, K.1    Crespo, P.2    Eickhoff, H.3    Haberer, T.4    Pawelke, J.5    Schardt, D.6
  • 14
    • 27644529469 scopus 로고    scopus 로고
    • Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilities
    • Crespo P, Barthel T, Frais-Kölbl H, Griesmayer E, Heidel K, Parodi K, et al. Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilities. IEEE Trans Nucl Sci 2005;52:980-7.
    • (2005) IEEE Trans Nucl Sci , vol.52 , pp. 980-987
    • Crespo, P.1    Barthel, T.2    Frais-Kölbl, H.3    Griesmayer, E.4    Heidel, K.5    Parodi, K.6
  • 15
    • 51149120071 scopus 로고    scopus 로고
    • Lauckner K. Entwicklung eines 3D Rekonstruktionsverfahrens für die Kontrolle der Tumorbehandlung mit Schwerionen mittels der Positronen-Emissions- Tomographie. Wiss.-Tech. Berichte FZR-264:1999.
    • Lauckner K. Entwicklung eines 3D Rekonstruktionsverfahrens für die Kontrolle der Tumorbehandlung mit Schwerionen mittels der Positronen-Emissions- Tomographie. Wiss.-Tech. Berichte FZR-264:1999.
  • 20
    • 51149123764 scopus 로고    scopus 로고
    • Private communication
    • Haberer T. Private communication. 2006.
    • (2006)
    • Haberer, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.