메뉴 건너뛰기




Volumn 22, Issue 4, 2008, Pages 319-326

Transcranial electric motor evoked potential detection of compressional peroneal nerve injury in the lateral decubitus position

Author keywords

Intraoperative neurophysiological monitoring; Lateral decubitus position; Motor evoked potentials; Peroneal nerve palsy; Somatosensory evoked potentials

Indexed keywords

BIOELECTRIC POTENTIALS; DATA COMPRESSION; ELECTRIC LOCOMOTIVES; ELECTRIC MACHINERY; ELECTRIC MOTORS; SURGERY;

EID: 51049115122     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-008-9136-x     Document Type: Article
Times cited : (10)

References (35)
  • 2
    • 0024975584 scopus 로고
    • Peroneal nerve palsy following sequential pneumatic compression
    • Pittman GR. Peroneal nerve palsy following sequential pneumatic compression. JAMA 1989; 261:2201-2202
    • (1989) JAMA , vol.261 , pp. 2201-2202
    • Pittman, G.R.1
  • 3
    • 0033774403 scopus 로고    scopus 로고
    • Peroneal nerve palsy following intermittent sequential pneumatic compression
    • McGrory BJ, Burke DW. Peroneal nerve palsy following intermittent sequential pneumatic compression. Orthopedics 2000; 23:1103-1105
    • (2000) Orthopedics , vol.23 , pp. 1103-1105
    • McGrory, B.J.1    Burke, D.W.2
  • 4
    • 33344464688 scopus 로고    scopus 로고
    • Bilateral peroneal nerve palsy caused by intermittent pneumatic compression
    • Fukuda H. Bilateral peroneal nerve palsy caused by intermittent pneumatic compression. Intern Med 2006; 45:93-94
    • (2006) Intern Med , vol.45 , pp. 93-94
    • Fukuda, H.1
  • 5
    • 0018582912 scopus 로고
    • Lower extremity complications of the lithotomy position: Prevention and management
    • Leff RG, Shapiro SR. Lower extremity complications of the lithotomy position: Prevention and management. J Urol 1979; 122:138-139
    • (1979) J Urol , vol.122 , pp. 138-139
    • Leff, R.G.1    Shapiro, S.R.2
  • 6
    • 0028219589 scopus 로고
    • Complications of the exaggerated lithotomy position: A review of 177 cases
    • Angermeier KW, Jordan GH. Complications of the exaggerated lithotomy position: A review of 177 cases. J Urol 1994; 151:866-868
    • (1994) J Urol , vol.151 , pp. 866-868
    • Angermeier, K.W.1    Jordan, G.H.2
  • 7
    • 0034079592 scopus 로고    scopus 로고
    • Bilateral lower extremity compartment syndrome following prolonged surgery in the low lithotomy position with serial compression stockings
    • Verdolin MH, Toth AS, Schroeder R. Bilateral lower extremity compartment syndrome following prolonged surgery in the low lithotomy position with serial compression stockings Anesthesiology 2000; 92:1189-1191
    • (2000) Anesthesiology , vol.92 , pp. 1189-1191
    • Verdolin, M.H.1    Toth, A.S.2    Schroeder, R.3
  • 8
    • 4544309488 scopus 로고    scopus 로고
    • Well-limb compartment syndrome after prolonged lateral decubitus positioning
    • Cascio BM, Buchowski JM, Frassica FJ. Well-limb compartment syndrome after prolonged lateral decubitus positioning. J Bone Joint Surg 2004; 86A:2038-2040
    • (2004) J Bone Joint Surg , vol.86 A , pp. 2038-2040
    • Cascio, B.M.1    Buchowski, J.M.2    Frassica, F.J.3
  • 11
    • 0027404029 scopus 로고
    • Intraoperative somatosensory evoked potential monitoring predicts peripheral nerve injury during cardiac surgery
    • Hickey C, Gugino LD, Aglio LS, Mark JB, Son SL, Maddi R. Intraoperative somatosensory evoked potential monitoring predicts peripheral nerve injury during cardiac surgery. Anesthesiology 1993; 78:29-35
    • (1993) Anesthesiology , vol.78 , pp. 29-35
    • Hickey, C.1    Gugino, L.D.2    Aglio, L.S.3    Mark, J.B.4    Son, S.L.5    Maddi, R.6
  • 12
    • 0028103865 scopus 로고
    • Somatosensory evoked potential monitoring of the brachial plexus to predict nerve injury during internal mammary artery harvest: Intraoperative comparisons of the Rultract and Pittman sternal retractors
    • Jellish WS, Martucci J, Blakeman B, Hudson E. Somatosensory evoked potential monitoring of the brachial plexus to predict nerve injury during internal mammary artery harvest: Intraoperative comparisons of the Rultract and Pittman sternal retractors. J Cardiothorac Vasc Anesth 1994; 8:398-403
    • (1994) J Cardiothorac Vasc Anesth , vol.8 , pp. 398-403
    • Jellish, W.S.1    Martucci, J.2    Blakeman, B.3    Hudson, E.4
  • 13
    • 0028070462 scopus 로고
    • Evoked potential monitoring of the upper extremities during thoracic and lumbar spinal deformity surgery: A prospective study
    • O'Brien MF, Lenke LG, Bridwell KH, Padberg A, Stokes M. Evoked potential monitoring of the upper extremities during thoracic and lumbar spinal deformity surgery: A prospective study. J Spinal Disord 1994; 7:277-284
    • (1994) J Spinal Disord , vol.7 , pp. 277-284
    • O'Brien, M.F.1    Lenke, L.G.2    Bridwell, K.H.3    Padberg, A.4    Stokes, M.5
  • 14
    • 0034586201 scopus 로고    scopus 로고
    • Prevention of positional brachial plexopathy during surgical correction of scoliosis
    • Schwartz D, Drummond D, Hahn M, et al. Prevention of positional brachial plexopathy during surgical correction of scoliosis. J Spinal Dis 2000; 2:178-182
    • (2000) J Spinal Dis , vol.2 , pp. 178-182
    • Schwartz, D.1    Drummond, D.2    Hahn, M.3
  • 15
    • 0033989094 scopus 로고    scopus 로고
    • Intraoperative SSEP detection of ulnar nerve compression or ischemia in an obese patient: A unique complication associated with a specialized spinal retraction system
    • Baumann SB, Welch WC, Bloom MJ. Intraoperative SSEP detection of ulnar nerve compression or ischemia in an obese patient: A unique complication associated with a specialized spinal retraction system. Arch Phys Med Rehabil 2000; 81:130-132
    • (2000) Arch Phys Med Rehabil , vol.81 , pp. 130-132
    • Baumann, S.B.1    Welch, W.C.2    Bloom, M.J.3
  • 16
    • 2342433422 scopus 로고    scopus 로고
    • Use of somatosensory evoked potentials to detect peripheral ischemia and potential injury resulting from positioning of the surgical patient: Case reports and discussion
    • Jones SC, Fernau R, Woeltjen BL. Use of somatosensory evoked potentials to detect peripheral ischemia and potential injury resulting from positioning of the surgical patient: Case reports and discussion. Spine J 2004; 4:360-362
    • (2004) Spine J , vol.4 , pp. 360-362
    • Jones, S.C.1    Fernau, R.2    Woeltjen, B.L.3
  • 17
    • 33646170947 scopus 로고    scopus 로고
    • The use of somatosensory evoked potentials to determine the relationship between patient positioning and impending upper extremity nerve injury during spine surgery: A retrospective analysis
    • Kamel IR, Drum ET, Koch SA, Whitten BA, Gaughan JP, et al. The use of somatosensory evoked potentials to determine the relationship between patient positioning and impending upper extremity nerve injury during spine surgery: A retrospective analysis. Anesthes Analg 2006; 102:1538-1542
    • (2006) Anesthes Analg , vol.102 , pp. 1538-1542
    • Kamel, I.R.1    Drum, E.T.2    Koch, S.A.3    Whitten, B.A.4    Gaughan, J.P.5
  • 18
    • 35649015752 scopus 로고    scopus 로고
    • Neurophysiological identification of position-induced neurologic injury during anterior cervical spine surgery
    • Epub 2006 Sep 8
    • Schwartz DM, Sestokas AK, Hilibrand AS, Vaccaro AR, Bose B, Li M, Albert TJ. Neurophysiological identification of position-induced neurologic injury during anterior cervical spine surgery. J Clin Monit Comput. 2006; 20:437-444. Epub 2006 Sep 8
    • (2006) J Clin Monit Comput , vol.20 , pp. 437-444
    • Schwartz, D.M.1    Sestokas, A.K.2    Hilibrand, A.S.3    Vaccaro, A.R.4    Bose, B.5    Li, M.6    Albert, T.J.7
  • 19
    • 2642528878 scopus 로고    scopus 로고
    • Comparison of transcranial electric motor, somatosensory evoked potential monitoring during cervical spine surgery
    • Hilibrand AS, Schwartz DM, Sethuraman V, Vaccaro AR, Albert TJ. Comparison of transcranial electric motor, somatosensory evoked potential monitoring during cervical spine surgery. J Bone Joint Surg Am 2004; 86-A:1248-1253
    • (2004) J Bone Joint Surg Am , vol.86 A , pp. 1248-1253
    • Hilibrand, A.S.1    Schwartz, D.M.2    Sethuraman, V.3    Vaccaro, A.R.4    Albert, T.J.5
  • 23
    • 0036618492 scopus 로고    scopus 로고
    • A systems-based algorithmic approach to intraoperative neurophysiological monitoring during spinal surgery
    • Schwartz DM, Sestokas AK. A systems-based algorithmic approach to intraoperative neurophysiological monitoring during spinal surgery. Semin Spine Surg 2002; 14:136-145
    • (2002) Semin Spine Surg , vol.14 , pp. 136-145
    • Schwartz, D.M.1    Sestokas, A.K.2
  • 24
    • 1542379004 scopus 로고    scopus 로고
    • Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion
    • Bose B, Sestokas AK, Schwartz DM. Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion. Spine J 2004; 4:202-207
    • (2004) Spine J , vol.4 , pp. 202-207
    • Bose, B.1    Sestokas, A.K.2    Schwartz, D.M.3
  • 25
  • 27
    • 0032944028 scopus 로고    scopus 로고
    • Nerve injury associated with anesthesia: A closed claims analysis
    • Cheney FW, Domino KB, Caplan RA, Posner KL. Nerve injury associated with anesthesia: A closed claims analysis. Anesthesiology 1999; 90:1062-1069
    • (1999) Anesthesiology , vol.90 , pp. 1062-1069
    • Cheney, F.W.1    Domino, K.B.2    Caplan, R.A.3    Posner, K.L.4
  • 28
    • 11444269860 scopus 로고    scopus 로고
    • Intraoperative positioning nerve injuries
    • Winfree CJ, Kline DG. Intraoperative positioning nerve injuries. Surg Neurol 2005; 63:5-18
    • (2005) Surg Neurol , vol.63 , pp. 5-18
    • Winfree, C.J.1    Kline, D.G.2
  • 29
    • 0015841695 scopus 로고
    • Postoperative peripheral neuropathies
    • Parks BJ. Postoperative peripheral neuropathies. Surgery 1973; 74:348-357
    • (1973) Surgery , vol.74 , pp. 348-357
    • Parks, B.J.1
  • 30
    • 0025968847 scopus 로고
    • Somatosensory-evoked potential monitored during total hip arthroplasty
    • Black DL, Reckling FW, Porter SS. Somatosensory-evoked potential monitored during total hip arthroplasty. Clin Orthop Relat Res 1991; 262:170-177
    • (1991) Clin Orthop Relat Res , vol.262 , pp. 170-177
    • Black, D.L.1    Reckling, F.W.2    Porter, S.S.3
  • 31
    • 0024797092 scopus 로고
    • Intraoperative cortical somatosensory evoked potentials for detection of sciatic neuropathy during total hip arthroplasty
    • Porter SS, Black DL, Reckling FW, Mason J. Intraoperative cortical somatosensory evoked potentials for detection of sciatic neuropathy during total hip arthroplasty. J Clin Anesth 1989; 1:170-176
    • (1989) J Clin Anesth , vol.1 , pp. 170-176
    • Porter, S.S.1    Black, D.L.2    Reckling, F.W.3    Mason, J.4
  • 32
    • 0027976091 scopus 로고
    • Efficacy of corticosomatosensory evoked potential monitoring in predicting and/or preventing sciatic nerve palsy during total hip arthroplasty
    • Rasmussen TJ, Black DL, Bruce RP, Reckling FW. Efficacy of corticosomatosensory evoked potential monitoring in predicting and/or preventing sciatic nerve palsy during total hip arthroplasty. J Arthroplasty 1994; 9:53-61
    • (1994) J Arthroplasty , vol.9 , pp. 53-61
    • Rasmussen, T.J.1    Black, D.L.2    Bruce, R.P.3    Reckling, F.W.4
  • 33
    • 0028035379 scopus 로고
    • Intraoperative evoked potential monitoring in acetabular surgery
    • Calder HB, Mast J, Johnstone C. Intraoperative evoked potential monitoring in acetabular surgery. Clin Orthop Relat Res 1994; 305:160-167
    • (1994) Clin Orthop Relat Res , vol.305 , pp. 160-167
    • Calder, H.B.1    Mast, J.2    Johnstone, C.3
  • 34
    • 0037111880 scopus 로고    scopus 로고
    • Intraoperative neurophysiologic detection of iatrogenic C5 nerve root injury during laminectomy for cervical compression myelopathy
    • Fan D, Schwartz D, Vaccaro A, Hilibrand A, Albert T. Intraoperative neurophysiologic detection of iatrogenic C5 nerve root injury during laminectomy for cervical compression myelopathy. Spine 2002; 27:2499-2502
    • (2002) Spine , vol.27 , pp. 2499-2502
    • Fan, D.1    Schwartz, D.2    Vaccaro, A.3    Hilibrand, A.4    Albert, T.5
  • 35
    • 34347219467 scopus 로고    scopus 로고
    • Neurophysiological detection of iatrogenic C5 nerve injury during anterior cervical spine surgery
    • Bose B, Sestokas AK, Schwartz DM. Neurophysiological detection of iatrogenic C5 nerve injury during anterior cervical spine surgery. J Neurosurg 2007;6:381-385
    • (2007) J Neurosurg , vol.6 , pp. 381-385
    • Bose, B.1    Sestokas, A.K.2    Schwartz, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.