메뉴 건너뛰기




Volumn 5116 LNCS, Issue , 2008, Pages 635-642

Multi-projection correlation imaging as a new diagnostic tool for improved breast cancer detection

Author keywords

Breast imaging; Correlation imaging; Hotelling observer; Optimization; Tomosynthesis

Indexed keywords

BREAST IMAGING; CORRELATION IMAGING; DIGITAL MAMMOGRAPHY; HOTELLING OBSERVER; TOMOSYNTHESIS;

EID: 50949127690     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-540-70538-3_88     Document Type: Conference Paper
Times cited : (2)

References (7)
  • 1
    • 0032748266 scopus 로고    scopus 로고
    • Relative Influence of quantum, and anatomical noise on the detection of subtle lung nodules in chest radiographs
    • Samei, E., Flynn, M.J., Eyler, W.R.: Relative Influence of quantum, and anatomical noise on the detection of subtle lung nodules in chest radiographs. Radiology 213, 727-734 (1999)
    • (1999) Radiology , vol.213 , pp. 727-734
    • Samei, E.1    Flynn, M.J.2    Eyler, W.R.3
  • 3
    • 34247617653 scopus 로고    scopus 로고
    • Multiprojection Correlation Imaging for Improved Detection of Pulmonary Nodules
    • Samei, E., Stebbins, S.A., Dobbins, J.T., et al.: Multiprojection Correlation Imaging for Improved Detection of Pulmonary Nodules. Am. J. Roentgenol. 188, 1239-1245 (2007)
    • (2007) Am. J. Roentgenol , vol.188 , pp. 1239-1245
    • Samei, E.1    Stebbins, S.A.2    Dobbins, J.T.3
  • 4
    • 41449091335 scopus 로고    scopus 로고
    • A mathematical model platform for optimizing a multi-projection breast imaging system
    • Chawla, A., Samei, E., Saunders, R., et al.: A mathematical model platform for optimizing a multi-projection breast imaging system. Med. Phys. 35(4), 1337-1345 (2008)
    • (2008) Med. Phys , vol.35 , Issue.4 , pp. 1337-1345
    • Chawla, A.1    Samei, E.2    Saunders, R.3
  • 5
    • 0041461316 scopus 로고    scopus 로고
    • A method for modifying the image quality parameters of digital radiographic images
    • Saunders, R.S., Samei, E.: A method for modifying the image quality parameters of digital radiographic images. Med. Phys. 30, 3006-3017 (2003)
    • (2003) Med. Phys , vol.30 , pp. 3006-3017
    • Saunders, R.S.1    Samei, E.2
  • 6
    • 33745655231 scopus 로고    scopus 로고
    • Voting strategy for artifact reduction in digital breast tomosynthesis
    • Wu, T., Moore, R.H., Kopans, D.B.: Voting strategy for artifact reduction in digital breast tomosynthesis. Med. Phys. 33, 2461 (2006)
    • (2006) Med. Phys , vol.33 , pp. 2461
    • Wu, T.1    Moore, R.H.2    Kopans, D.B.3
  • 7
    • 33745430674 scopus 로고    scopus 로고
    • Zhou, L., Oldan, J., Fisher, P., et al.:Low-contrast lesion detection in tomosynthetic breast imaging using a realistic breast phantom. pp. 61425AI-A12 (1425)
    • Zhou, L., Oldan, J., Fisher, P., et al.:Low-contrast lesion detection in tomosynthetic breast imaging using a realistic breast phantom. pp. 61425AI-A12 (1425)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.