메뉴 건너뛰기




Volumn , Issue , 2008, Pages 2386-2389

Geometric correction for Cone-Beam CT reconstruction and artifacts reduction

Author keywords

Cone beam CT; Detector correction; FDK algorithm; Ring artifacts reduction; Shading artifacts reduction

Indexed keywords

ALGORITHMS; BIOCOMMUNICATIONS; BIOINFORMATICS; BIOMEDICAL ENGINEERING; BOOLEAN FUNCTIONS; COMPUTATIONAL GEOMETRY; COMPUTER NETWORKS; ELECTRIC INSTRUMENT TRANSFORMERS; IMAGE ENHANCEMENT; IMAGE RESOLUTION; INFORMATION SCIENCE; RESTORATION;

EID: 50949124836     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICBBE.2008.929     Document Type: Conference Paper
Times cited : (12)

References (10)
  • 1
    • 33644932630 scopus 로고    scopus 로고
    • Megavoltage cone-beam CT: System description and clinical applications
    • O. Morin, A. Gillis, J. Chen and M. Aubin, "Megavoltage cone-beam CT: System description and clinical applications", Medical Dosimetry, Volume 31, Issue 1, Pages 51-61
    • Medical Dosimetry , vol.31 , Issue.1 , pp. 51-61
    • Morin, O.1    Gillis, A.2    Chen, J.3    Aubin, M.4
  • 3
    • 0027659307 scopus 로고
    • A general cone-beam reconstruction algorithm
    • G. Wang et al, "A general cone-beam reconstruction algorithm", IEEE Trans. on Med. Ima, 1993, 12:486-496.
    • (1993) IEEE Trans. on Med. Ima , vol.12 , pp. 486-496
    • Wang, G.1
  • 5
    • 84938214814 scopus 로고    scopus 로고
    • Zhang xiao fan, He Mingyi, Fast algorithm 3-D CT based on FDK method, Computer Engineering and Applications, 2004, No.31:208-221
    • Zhang xiao fan, He Mingyi, "Fast algorithm 3-D CT based on FDK method", Computer Engineering and Applications, 2004, No.31:208-221
  • 6
    • 84938209815 scopus 로고    scopus 로고
    • Exxim Computing Corporation
    • Exxim Computing Corporation, http://www.exxim-cc.com/download.htm
  • 8
    • 34447498810 scopus 로고    scopus 로고
    • Reduction of Artifacts Induced by Misaligned Geometry in Cone-Beam CT
    • Aug, Pages
    • Sun, Y., Hou, Y., Hu, J., "Reduction of Artifacts Induced by Misaligned Geometry in Cone-Beam CT", IEEE Transactions on Biomedical Engineering , Aug. 2007, Volume 54, Issue 8, Page(s):1461-1471
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.8 , pp. 1461-1471
    • Sun, Y.1    Hou, Y.2    Hu, J.3
  • 9
    • 4344716167 scopus 로고    scopus 로고
    • Reduction of ring artifacts in high resolution micro-CT reconstructions
    • Jul;
    • Jan Sijbers, Andrei Postnov, "Reduction of ring artifacts in high resolution micro-CT reconstructions", Physics in Medicine and Biology, 2004 Jul; 49(14):N247-53
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.14
    • Sijbers, J.1    Postnov, A.2
  • 10
    • 33745171658 scopus 로고    scopus 로고
    • Fast correction of metal artifacts in CT images
    • Jun;
    • Gu Jian-wei, "Fast correction of metal artifacts in CT images", Chinese Journal of Stereology and Image Analysis, 2005 Jun; 10(2):108-111
    • (2005) Chinese Journal of Stereology and Image Analysis , vol.10 , Issue.2 , pp. 108-111
    • Gu, J.-W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.