ALGORITHM;
ARTICLE;
COLLIMATOR;
CORPUS STRIATUM;
DIAGNOSTIC ACCURACY;
GRAY MATTER;
IMAGE RECONSTRUCTION;
MONTE CARLO METHOD;
PRIORITY JOURNAL;
SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY;
WHITE MATTER;
ALGORITHMS;
ARTIFACTS;
BRAIN;
DATA INTERPRETATION, STATISTICAL;
HUMANS;
IMAGING, THREE-DIMENSIONAL;
MONTE CARLO METHOD;
PHANTOMS, IMAGING;
SCATTERING, RADIATION;
SENSITIVITY AND SPECIFICITY;
SIGNAL PROCESSING, COMPUTER-ASSISTED;
SUBTRACTION TECHNIQUE;
TOMOGRAPHY, EMISSION-COMPUTED, SINGLE-PHOTON;
Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations
I. Buvat M. Rodriguez-Villafuerte A. Todd-Pokropek H. Benali R. Di Paola 1995 Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations J Nucl Med 36 1476 1488
A comparison of scatter compensation methods in SPECT: Subtraction-based techniques versus iterative reconstruction with accurate modeling of the scatter response
E.C. Frey B.M.W. Tsui M. Ljungberg 1992 A comparison of scatter compensation methods in SPECT: subtraction-based techniques versus iterative reconstruction with accurate modeling of the scatter response Conference Record of the 1992 Nuclear Science Symposium and Medical Imaging Conference 2 1035 1037
Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT
H. Iida Y. Narita H. Kado A. Kashikura S. Sugawara Y. Shoji 1998 Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT J Nucl Med 39 181 189
Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities
K.M. Kim A. Varrone H. Watabe M. Shidahara M. Fujita R.B. Innis 2003 Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities J Nucl Med 44 512 519
Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imaging
G.L. Zeng G.T. Gullberg 1992 Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imaging IEEE Trans Nucl Sci 39 1444 1453
Iterative reconstruction of fluorine-18 SPECT using geometric point response correction
G.L. Zeng G.T. Gullberg C. Bai P.E. Christian F. Trisjono E.V.R. Di Bella 1998 Iterative reconstruction of fluorine-18 SPECT using geometric point response correction J Nucl Med 39 124 130
A Monte Carlo program for the simulation of scintillation camera characteristics
M. Ljungberg S.E. Strand 1989 A Monte Carlo program for the simulation of scintillation camera characteristics Comput Methods Programs Biomed 29 257 272
SPECT collimator dependency of scatter and validation of transmission-dependent scatter compensation methodologies
K.M. Kim H. Watabe M. Shidahara Y. Ishida H. Iida 2001 SPECT collimator dependency of scatter and validation of transmission-dependent scatter compensation methodologies IEEE Trans Nucl Sci 48 689 696
Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation
F.J. Beekman H.W. de Jong S. van Geloven 2002 Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation IEEE Trans Med Imaging 21 867 877
A fast projector-backprojector pair modeling the asymmetric, spatially varying scatter response function for scatter compensation in SPECT imaging
E.C. Frey Z.W. Ju B.M.W. Tsui 1993 A fast projector-backprojector pair modeling the asymmetric, spatially varying scatter response function for scatter compensation in SPECT imaging IEEE Trans Nucl Sci 40 1192 1197