-
1
-
-
0030999897
-
Poor prognosis for existing monitors in the intensive care unit
-
C. Tsien, J. Fackler, "Poor prognosis for existing monitors in the intensive care unit," Crit. Care Med. 1997; 25(4):614-619
-
(1997)
Crit. Care Med
, vol.25
, Issue.4
, pp. 614-619
-
-
Tsien, C.1
Fackler, J.2
-
2
-
-
0026111234
-
The median filter as a preprocessor for a patient monitor limit alarm system in intensive care
-
A. Makivirta, E. Koski, A. Kari and T. Sukuvaara, "The median filter as a preprocessor for a patient monitor limit alarm system in intensive care," Comput. Methods Programs Biomed. 1991; 34:139-144
-
(1991)
Comput. Methods Programs Biomed
, vol.34
, pp. 139-144
-
-
Makivirta, A.1
Koski, E.2
Kari, A.3
Sukuvaara, T.4
-
3
-
-
0025055154
-
Physiologic trend detection and artifact rejection: A parallel implementation of a multi-state Kalman filtering algorithm
-
D. F. Sittig, M. Factor, "Physiologic trend detection and artifact rejection: a parallel implementation of a multi-state Kalman filtering algorithm," Comput. Methods Programs Biomed. 1990;31(1):1-10
-
(1990)
Comput. Methods Programs Biomed
, vol.31
, Issue.1
, pp. 1-10
-
-
Sittig, D.F.1
Factor, M.2
-
4
-
-
6344263925
-
Reduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure
-
W. Zong, G. B. Moody and R. G. Mark, "Reduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure," Med. Biol. Eng. Comput. 2004,42(5):698-706
-
(2004)
Med. Biol. Eng. Comput
, vol.42
, Issue.5
, pp. 698-706
-
-
Zong, W.1
Moody, G.B.2
Mark, R.G.3
-
5
-
-
38049074713
-
Using the Blood Pressure Waveform to Reduce Critical False ECG Alarms
-
G. D. Clifford, A. Aboukhalil, J. X. Sun, W. Zong, B. A. Janz, et al., "Using the Blood Pressure Waveform to Reduce Critical False ECG Alarms," Comput. in Cardiol. 2006; 33:829-832
-
(2006)
Comput. in Cardiol
, vol.33
, pp. 829-832
-
-
Clifford, G.D.1
Aboukhalil, A.2
Sun, J.X.3
Zong, W.4
Janz, B.A.5
-
6
-
-
0036945542
-
MIMIC II: A massive temporal ICU patient database to support research in intelligent patient monitoring
-
M. Saeed, C. Lieu, G. Raber, R. G. Mark, "MIMIC II: A massive temporal ICU patient database to support research in intelligent patient monitoring," Comput. in Cardiol. 2002; 29:641-644
-
(2002)
Comput. in Cardiol
, vol.29
, pp. 641-644
-
-
Saeed, M.1
Lieu, C.2
Raber, G.3
Mark, R.G.4
-
7
-
-
38049078513
-
A signal abnormality index for arterial blood pressure waveforms
-
J. X. Sun, A. T. Reisner, R. G. Mark, "A signal abnormality index for arterial blood pressure waveforms," Comput. in Cardiol. 2006; 33:13-16
-
(2006)
Comput. in Cardiol
, vol.33
, pp. 13-16
-
-
Sun, J.X.1
Reisner, A.T.2
Mark, R.G.3
-
8
-
-
4143146627
-
An open-source algorithm to detect onset of arterial blood pressure pulses
-
W. Zong, T. Heldt, G. B. Moody, R. G. Mark, "An open-source algorithm to detect onset of arterial blood pressure pulses," Comput. in Cardiol. 2003; 30:259-262
-
(2003)
Comput. in Cardiol
, vol.30
, pp. 259-262
-
-
Zong, W.1
Heldt, T.2
Moody, G.B.3
Mark, R.G.4
-
10
-
-
38049013310
-
Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter
-
Q. Li, R. G. Mark, G. D. Clifford, "Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter," Physiol. Meas., 2008; 29 (1): 15-32
-
(2008)
Physiol. Meas
, vol.29
, Issue.1
, pp. 15-32
-
-
Li, Q.1
Mark, R.G.2
Clifford, G.D.3
|