메뉴 건너뛰기




Volumn 78, Issue 5, 2008, Pages 902-907

Stability of zygomatic plate-screw orthodontic anchorage system: A finite element analysis

Author keywords

Finite element analysis; Stability; Zygomatic anchorage

Indexed keywords


EID: 50949108803     PISSN: 00033219     EISSN: 00033219     Source Type: Journal    
DOI: 10.2319/081607-379.1     Document Type: Article
Times cited : (19)

References (14)
  • 3
    • 4844229252 scopus 로고    scopus 로고
    • Clinical suitability of titanium microscrews for orthodontic anchorage-preliminary experiences
    • Fritz U, Ehmer A, Diedrich P. Clinical suitability of titanium microscrews for orthodontic anchorage-preliminary experiences. J Orofac Orthop. 2004;65:410-418.
    • (2004) J Orofac Orthop , vol.65 , pp. 410-418
    • Fritz, U.1    Ehmer, A.2    Diedrich, P.3
  • 4
    • 0035407943 scopus 로고    scopus 로고
    • Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion
    • Park HS, Bae SM, Kyung HM, Sung JH. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod. 2001;35:417-422.
    • (2001) J Clin Orthod , vol.35 , pp. 417-422
    • Park, H.S.1    Bae, S.M.2    Kyung, H.M.3    Sung, J.H.4
  • 5
    • 0030325414 scopus 로고    scopus 로고
    • The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem
    • Wehrbein H, Merz BR, Diedrich P, Glatzmaier J. The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem. Clin Oral Implants Res. 1996;7:410-416.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 410-416
    • Wehrbein, H.1    Merz, B.R.2    Diedrich, P.3    Glatzmaier, J.4
  • 6
    • 4444337381 scopus 로고    scopus 로고
    • Implant-anchored orthodontics for partially edentulous malocclu-sions in children and adults
    • Roberts WE, Engen DW, Schneider PM, Hohlt WF. Implant-anchored orthodontics for partially edentulous malocclu-sions in children and adults. Am J Orthod Dentofacial Orthop. 2004;126:302-304.
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , pp. 302-304
    • Roberts, W.E.1    Engen, D.W.2    Schneider, P.M.3    Hohlt, W.F.4
  • 7
    • 33646460910 scopus 로고    scopus 로고
    • New generation open-bite treatment with zygomatic anchorage
    • Erverdi N, Usumez S, Solak A. New generation open-bite treatment with zygomatic anchorage. Angle Orthod. 2006;76:519-526.
    • (2006) Angle Orthod , vol.76 , pp. 519-526
    • Erverdi, N.1    Usumez, S.2    Solak, A.3
  • 8
    • 18244396344 scopus 로고    scopus 로고
    • Zygomatic anchorage for en masse retraction in the treatment of severe Class II division 1
    • Erverdi N, Acar A. Zygomatic anchorage for en masse retraction in the treatment of severe Class II division 1. Angle Orthod. 2005;75:483-590.
    • (2005) Angle Orthod , vol.75 , pp. 483-590
    • Erverdi, N.1    Acar, A.2
  • 9
    • 3242673373 scopus 로고    scopus 로고
    • The use of skeletal anchorage in open bite treatment: A cephalometric evaluation
    • Erverdi N, Keles A, Nanda R. The use of skeletal anchorage in open bite treatment: a cephalometric evaluation. Angle Orthod. 2004;74:381-390.
    • (2004) Angle Orthod , vol.74 , pp. 381-390
    • Erverdi, N.1    Keles, A.2    Nanda, R.3
  • 10
    • 33744910089 scopus 로고    scopus 로고
    • Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system
    • Sugawara J, Kanzaki R, Takahashi I, Nagasaka H, Nanda R. Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system. Am J Orthod Dentofac Orthop. 2006;129:723-733.
    • (2006) Am J Orthod Dentofac Orthop , vol.129 , pp. 723-733
    • Sugawara, J.1    Kanzaki, R.2    Takahashi, I.3    Nagasaka, H.4    Nanda, R.5
  • 12
    • 33744982083 scopus 로고    scopus 로고
    • Orthodontic anchorage system using a locking plate and self-drilling screws
    • Hibi H, Ueda M, Sakai M, Ikemori Y. Orthodontic anchorage system using a locking plate and self-drilling screws. J Oral Maxillofac Surg. 2006;64:1173-1175.
    • (2006) J Oral Maxillofac Surg , vol.64 , pp. 1173-1175
    • Hibi, H.1    Ueda, M.2    Sakai, M.3    Ikemori, Y.4
  • 13
    • 0036592503 scopus 로고    scopus 로고
    • Finite element analysis of the stresses around endos-seous implants in various reconstructed mandibular models
    • Nagasao T, Kobayashi M, Tsuchiya Y, Kaneko T, Nakajima T. Finite element analysis of the stresses around endos-seous implants in various reconstructed mandibular models. J Craniomaxillofac Surg. 2002;30:170-177.
    • (2002) J Craniomaxillofac Surg , vol.30 , pp. 170-177
    • Nagasao, T.1    Kobayashi, M.2    Tsuchiya, Y.3    Kaneko, T.4    Nakajima, T.5
  • 14
    • 85180985305 scopus 로고    scopus 로고
    • Geng JP, Tan KBC. Liu GR: Application of finite element analysis in implant dentistry. J Prosth Dent. 2001;85:585-598.
    • Geng JP, Tan KBC. Liu GR: Application of finite element analysis in implant dentistry. J Prosth Dent. 2001;85:585-598.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.