메뉴 건너뛰기




Volumn , Issue , 2008, Pages 2628-2630

An efficient denoising procedure for magnetic resonance imaging

Author keywords

Denoising; Magnetic resonance imaging; Wavelet

Indexed keywords

ATOMS; BIOCOMMUNICATIONS; BIOINFORMATICS; BIOMEDICAL ENGINEERING; IMAGE PROCESSING; INFORMATION SCIENCE; MAGNETIC MATERIALS; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING;

EID: 50949093558     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICBBE.2008.990     Document Type: Conference Paper
Times cited : (7)

References (9)
  • 1
    • 6344254597 scopus 로고    scopus 로고
    • A method for modeling noise in medical images
    • Oct
    • P. Gravel, G. Beaudoin, J. A. De Guise, "A method for modeling noise in medical images," IEEE Trans. Med. Imag., vol. 23, no. 10, pp. 1221-1232,Oct.2004
    • (2004) IEEE Trans. Med. Imag , vol.23 , Issue.10 , pp. 1221-1232
    • Gravel, P.1    Beaudoin, G.2    De Guise, J.A.3
  • 2
    • 33645875326 scopus 로고    scopus 로고
    • Analytically exact correction scheme for signal extraction. from noisy magnitude MR signals
    • C. G. Koay and P. J. Basser, "Analytically exact correction scheme for signal extraction. from noisy magnitude MR signals," J. Magn. Reson. 179, pp.317-322 ,2006
    • (2006) J. Magn. Reson , vol.179 , pp. 317-322
    • Koay, C.G.1    Basser, P.J.2
  • 3
    • 0342647438 scopus 로고    scopus 로고
    • Low-complexity image denoising based on statistical modeling of wavelet coefficients
    • Jun
    • M. K. Mihcak, I. Kozinsev, K. Ramchandran, and P. Moulin, "Low-complexity image denoising based on statistical modeling of wavelet coefficients," IEEE Signal Process. Lett.,vol.7, no.6,pp.300-303, Jun. 1999.
    • (1999) IEEE Signal Process. Lett , vol.7 , Issue.6 , pp. 300-303
    • Mihcak, M.K.1    Kozinsev, I.2    Ramchandran, K.3    Moulin, P.4
  • 4
    • 0036959297 scopus 로고    scopus 로고
    • Bivariate shrinkage with local variance estimation
    • Dec
    • L. Sendur and I. W. Selesnick, "Bivariate shrinkage with local variance estimation," IEEE Signal Process. Lett., vol.9,no.12,pp.438-441, Dec. 2002.
    • (2002) IEEE Signal Process. Lett , vol.9 , Issue.12 , pp. 438-441
    • Sendur, L.1    Selesnick, I.W.2
  • 5
    • 0026759942 scopus 로고
    • Two applications of wavelet transforms in magnetic resonance imaging
    • Mar
    • D. Healy and J. Weaver, "Two applications of wavelet transforms in magnetic resonance imaging," IEEE Trans. Inf. Theory, vol. 38, no. 2, pp. 840-860, Mar. 1992.
    • (1992) IEEE Trans. Inf. Theory , vol.38 , Issue.2 , pp. 840-860
    • Healy, D.1    Weaver, J.2
  • 7
    • 0033322132 scopus 로고    scopus 로고
    • Wavelet-based Rician noise removal for magnetic resonance imaging
    • Oct
    • R. Nowak, "Wavelet-based Rician noise removal for magnetic resonance imaging," IEEE Trans. Image Process., vol. 8, no. 10, pp. 1408-1419, Oct. 1999.
    • (1999) IEEE Trans. Image Process , vol.8 , Issue.10 , pp. 1408-1419
    • Nowak, R.1
  • 8
    • 0037983986 scopus 로고    scopus 로고
    • A versatile wavelet domain noise filtration technique for medical imaging
    • Mar
    • A. Pizurica, W. Philips, I. Lemahieu, and M. Acheroy, "A versatile wavelet domain noise filtration technique for medical imaging," IEEE Trans. Med. Imag., vol. 22, no. 3, pp. 323-331, Mar. 2003.
    • (2003) IEEE Trans. Med. Imag , vol.22 , Issue.3 , pp. 323-331
    • Pizurica, A.1    Philips, W.2    Lemahieu, I.3    Acheroy, M.4
  • 9
    • 0041958932 scopus 로고
    • Ideal spatial adaptation by wavelet shrinkage
    • D. L. Donoho and I. M. Johnstone, "Ideal spatial adaptation by wavelet shrinkage," Biometrika, vol. 81, no. 3, pp. 425-455, 1994.
    • (1994) Biometrika , vol.81 , Issue.3 , pp. 425-455
    • Donoho, D.L.1    Johnstone, I.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.