1
-
-
0344141607
-
Comparison of structure extraction methods for in vivo trabecular bone measurements
-
Laib A., and Rüegsegger P. Comparison of structure extraction methods for in vivo trabecular bone measurements. Comput Med Imaging Graph 23 2 (1999) 69-74
-
(1999)
Comput Med Imaging Graph
, vol.23
, Issue.2
, pp. 69-74
-
-
Laib, A.1
Rüegsegger, P.2
-
2
-
-
0032463334
-
In vivo high resolution 3D-QCT of the human forearm
-
Laib A., Hauselmann H.J., and Rüegsegger P. In vivo high resolution 3D-QCT of the human forearm. Technol Health Care 6 5-6 (1998) 329-337
-
(1998)
Technol Health Care
, vol.6
, Issue.5-6
, pp. 329-337
-
-
Laib, A.1
Hauselmann, H.J.2
Rüegsegger, P.3
-
3
-
-
0020509916
-
Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis. Implications for the microanatomic and cellular mechanisms of bone loss
-
Parfitt A.M., Mathews C.H., Villanueva A.R., et al. Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis. Implications for the microanatomic and cellular mechanisms of bone loss. J Clin Invest 72 4 (1983) 1396-1409
-
(1983)
J Clin Invest
, vol.72
, Issue.4
, pp. 1396-1409
-
-
Parfitt, A.M.1
Mathews, C.H.2
Villanueva, A.R.3
-
4
-
-
0031020931
-
A new method for the model-independent assessment of thickness in three-dimensional images
-
Hildebrand T., and Rüegsegger P. A new method for the model-independent assessment of thickness in three-dimensional images. J Microsc 185 1 (1997) 67-75
-
(1997)
J Microsc
, vol.185
, Issue.1
, pp. 67-75
-
-
Hildebrand, T.1
Rüegsegger, P.2
-
5
-
-
34250018006
-
Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality
-
Epub ahead of print
-
MacNeil J.A., and Boyd S.K. Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Med Eng Phys (2007) Epub ahead of print
-
(2007)
Med Eng Phys
-
-
MacNeil, J.A.1
Boyd, S.K.2
-
6
-
-
34250013862
-
Load distribution and the predictive power of morphological indices in the distal radius
-
MacNeil J.A., and Boyd S.K. Load distribution and the predictive power of morphological indices in the distal radius. Bone 41 (2007) 129-137
-
(2007)
Bone
, vol.41
, pp. 129-137
-
-
MacNeil, J.A.1
Boyd, S.K.2
-
7
-
-
27944449749
-
In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
-
Boutroy S., Bouxsein M.L., Munoz F., and Delmas P.D. In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. J Clin Endocrinol Metab 90 12 (2005) 6508-6515
-
(2005)
J Clin Endocrinol Metab
, vol.90
, Issue.12
, pp. 6508-6515
-
-
Boutroy, S.1
Bouxsein, M.L.2
Munoz, F.3
Delmas, P.D.4
-
8
-
-
29644439392
-
Effects of sex and age on bone microstructure at the ultradistal radius: a population-based noninvasive in vivo assessment
-
Khosla S., Riggs B.L., Atkinson E.J., et al. Effects of sex and age on bone microstructure at the ultradistal radius: a population-based noninvasive in vivo assessment. J Bone Miner Res 21 1 (2006) 124-131
-
(2006)
J Bone Miner Res
, vol.21
, Issue.1
, pp. 124-131
-
-
Khosla, S.1
Riggs, B.L.2
Atkinson, E.J.3
-
9
-
-
0017252850
-
The distribution of cortical and trabecular bone mass along the lengths of the radius and ulna and the implications for in vivo bone mass measurements
-
Schlenker R.A., and VonSeggen W.W. The distribution of cortical and trabecular bone mass along the lengths of the radius and ulna and the implications for in vivo bone mass measurements. Calcif Tissue Res 20 1 (1976) 41-52
-
(1976)
Calcif Tissue Res
, vol.20
, Issue.1
, pp. 41-52
-
-
Schlenker, R.A.1
VonSeggen, W.W.2
-
10
-
-
50849140132
-
-
MacNeil JA, Boyd SK. Improved reproducibility of high resolution peripheral quantitative computed tomography for measurement of bone quality. Med Eng Phys, in press.
-
MacNeil JA, Boyd SK. Improved reproducibility of high resolution peripheral quantitative computed tomography for measurement of bone quality. Med Eng Phys, in press.
-
-
-
-
11
-
-
35748935928
-
Evaluation of three-dimensional image registration methodologies for in vivo micro-computed tomography
-
Boyd S.K., Moser S., Kuhn M., et al. Evaluation of three-dimensional image registration methodologies for in vivo micro-computed tomography. Ann Biomed Eng 34 10 (2006) 1587-1599
-
(2006)
Ann Biomed Eng
, vol.34
, Issue.10
, pp. 1587-1599
-
-
Boyd, S.K.1
Moser, S.2
Kuhn, M.3
|