-
2
-
-
4243060374
-
Learning to control a brain-machine interface for reaching and grasping by primates
-
J.M. Carmena et al., "Learning to control a brain-machine interface for reaching and grasping by primates," PLoS Biol, vol. 1, p. E42, 2003.
-
(2003)
PLoS Biol
, vol.1
-
-
Carmena, J.M.1
-
3
-
-
0034281273
-
Connecting brains to robots: An artificial body for studying the computational properties of neural tissues
-
B. D. Reger et al., "Connecting brains to robots: an artificial body for studying the computational properties of neural tissues," Artif Life, vol. 6, pp. 307-324, 2000.
-
(2000)
Artif Life
, vol.6
, pp. 307-324
-
-
Reger, B.D.1
-
4
-
-
38049090116
-
Bioelectronics closed-loop for hybrid neural networks: Towards a fully integrated approach,
-
Master thesis, University Bordeaux
-
G. Bontorin, "Bioelectronics closed-loop for hybrid neural networks: towards a fully integrated approach," Master thesis, University Bordeaux 1, 2006.
-
(2006)
, pp. 1
-
-
Bontorin, G.1
-
5
-
-
33947579763
-
Single-chip microelectronic system to interface with living cells
-
F. Heer et al., "Single-chip microelectronic system to interface with living cells," Biosens Bioelectron, vol. 22, pp. 2546-2553, 2007.
-
(2007)
Biosens Bioelectron
, vol.22
, pp. 2546-2553
-
-
Heer, F.1
-
7
-
-
85060333996
-
A multi-channel low-power circuit for implantable auditory neural recording microsystems
-
unpublished work
-
J. Wu, W. F. Feng, and W. C. Tang, "A multi-channel low-power circuit for implantable auditory neural recording microsystems," unpublished work.
-
-
-
Wu, J.1
Feng, W.F.2
Tang, W.C.3
-
8
-
-
21844471300
-
Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays
-
R. H. III Olsson et al., "Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays," Biomedical Engineering, IEEE Transactions on, vol. 52, pp. 1303-1311, 2005.
-
(2005)
Biomedical Engineering, IEEE Transactions on
, vol.52
, pp. 1303-1311
-
-
Olsson III, R.H.1
-
9
-
-
26244468380
-
Wireless multichannel biopotential recording using an integrated FM telemetry circuit
-
P. Mohseni, K. Najafi, S. J. Eliades, and X. Wang, "Wireless multichannel biopotential recording using an integrated FM telemetry circuit," Neural Systems and Rehabilitation Engineering, IEEE Transactions on, vol. 13, pp. 263-271, 2005.
-
(2005)
Neural Systems and Rehabilitation Engineering, IEEE Transactions on
, vol.13
, pp. 263-271
-
-
Mohseni, P.1
Najafi, K.2
Eliades, S.J.3
Wang, X.4
-
10
-
-
0034884441
-
Single-unit neural recording with active microelectrode arrays
-
Q. Bai and K. D. Wise, "Single-unit neural recording with active microelectrode arrays," Biomedical Engineering, IEEE Transactions on, vol. 48, pp. 911-920, 2001.
-
(2001)
Biomedical Engineering, IEEE Transactions on
, vol.48
, pp. 911-920
-
-
Bai, Q.1
Wise, K.D.2
-
11
-
-
0041695222
-
-
R. Rieger et al., Design of a low-noise preamplifier for nerve cuff electrode recording, Solid-State Circuits, IEEE Journal of, 38, pp. 1373-1379, 2003.
-
R. Rieger et al., "Design of a low-noise preamplifier for nerve cuff electrode recording," Solid-State Circuits, IEEE Journal of, vol. 38, pp. 1373-1379, 2003.
-
-
-
-
12
-
-
0038718680
-
-
R. R. Harrison and C. Charles, A low-power low-noise CMOS amplifier for neural recording applications, Solid-State Circuits, IEEE Journal of, 38, pp. 958-965, 2003.
-
R. R. Harrison and C. Charles, "A low-power low-noise CMOS amplifier for neural recording applications," Solid-State Circuits, IEEE Journal of, vol. 38, pp. 958-965, 2003.
-
-
-
-
13
-
-
0036806167
-
CMOS front-end amplifier dedicated to monitor very low amplitude signal from implantable sensors
-
Y. Hu and M. Sawan, "CMOS front-end amplifier dedicated to monitor very low amplitude signal from implantable sensors," Analog Integrated Circuits and Signal Processing, vol. 33, pp. 29-41, 2002.
-
(2002)
Analog Integrated Circuits and Signal Processing
, vol.33
, pp. 29-41
-
-
Hu, Y.1
Sawan, M.2
-
14
-
-
0346094449
-
A low noise multichannel integrated circuit for recording neuronal signals using microelectrode arrays
-
W. Dabrowski, P. Grybos, and A. M. Litke, "A low noise multichannel integrated circuit for recording neuronal signals using microelectrode arrays," Biosensors and Bioelectronics, vol. 19, pp. 749-76, 2004.
-
(2004)
Biosensors and Bioelectronics
, vol.19
, pp. 749-776
-
-
Dabrowski, W.1
Grybos, P.2
Litke, A.M.3
-
15
-
-
50649097730
-
MEA Amplifier with Blanking Circuit for Upright Microscopes - User Manual
-
Multi Channel Systems MCS
-
"MEA Amplifier with Blanking Circuit for Upright Microscopes - User Manual," Multi Channel Systems MCS, 2006.
-
(2006)
-
-
-
16
-
-
33646155104
-
Analog frontend for multichannel neuronal recording system with spike and LFP separation
-
Y. Perelman and R. Ginosar, "Analog frontend for multichannel neuronal recording system with spike and LFP separation," J Neurosci Methods, vol. 153, pp. 21-26, 2006.
-
(2006)
J Neurosci Methods
, vol.153
, pp. 21-26
-
-
Perelman, Y.1
Ginosar, R.2
-
17
-
-
2442710346
-
Evaluation of spike-detection algorithms fora brain-machine interface application
-
I. Obeid and P. D. Wolf, "Evaluation of spike-detection algorithms fora brain-machine interface application," Biomedical Engineering, IEEE Transactions on, vol. 51, pp. 905-911, 2004.
-
(2004)
Biomedical Engineering, IEEE Transactions on
, vol.51
, pp. 905-911
-
-
Obeid, I.1
Wolf, P.D.2
-
18
-
-
4344637641
-
High-density microelectrode arrays for electrophysiological activity imaging of neuronal networks
-
L. Berdondini et al., "High-density microelectrode arrays for electrophysiological activity imaging of neuronal networks," in Electronics, Circuits and Systems, The 8th IEEE International Conference on (ICECS 2001), 2001, pp. 1239-1242.
-
(2001)
Electronics, Circuits and Systems, The 8th IEEE International Conference on (ICECS
, pp. 1239-1242
-
-
Berdondini, L.1
-
19
-
-
0033930645
-
Intracellular features predicted by extracellular recordings in the hippocampus in vivo
-
D. A. Henze et al., "Intracellular features predicted by extracellular recordings in the hippocampus in vivo," J Neurophysiol, vol. 84, pp. 390-400, 2000.
-
(2000)
J Neurophysiol
, vol.84
, pp. 390-400
-
-
Henze, D.A.1
-
20
-
-
0035370406
-
Design Procedure for Two-Stage CMOS Transconductance Operational Amplifiers: A Tutorial
-
G. Palmisano, G. Palumbo, and S. Pennisi, "Design Procedure for Two-Stage CMOS Transconductance Operational Amplifiers: A Tutorial," Analog Integrated Circuits and Signal Processing, vol. 27, pp. 179-189, 2001.
-
(2001)
Analog Integrated Circuits and Signal Processing
, vol.27
, pp. 179-189
-
-
Palmisano, G.1
Palumbo, G.2
Pennisi, S.3
-
21
-
-
0025483058
-
-
M. S. J. Steyaert and W. M. C. Sansen, Power supply rejection ratio in operational transconductance amplifiers, Circuits and Systems, IEEE Transactions on, 37, pp. 1077-1084, 1990.
-
M. S. J. Steyaert and W. M. C. Sansen, "Power supply rejection ratio in operational transconductance amplifiers," Circuits and Systems, IEEE Transactions on, vol. 37, pp. 1077-1084, 1990.
-
-
-
-
22
-
-
50649088230
-
-
P. Cazenave, Integrated bipolar transistors modeling I: silicon devices (french book: Modélisation du transistor bipolaire intégré 1 : dispositifs au silicium) 1: Paris , Hermès science publ. , Lavoisier 2004.
-
P. Cazenave, Integrated bipolar transistors modeling I: silicon devices (french book: Modélisation du transistor bipolaire intégré 1 : dispositifs au silicium) vol. 1: Paris , Hermès science publ. , Lavoisier 2004.
-
-
-
-
23
-
-
1942478627
-
Cultured neurons coupled to microelectrode arrays: Circuit models, simulations and experimental data
-
S. Martinoia, P. Massobrio, M. Bove, and G. Massobrio, "Cultured neurons coupled to microelectrode arrays: circuit models, simulations and experimental data," Biomedical Engineering, IEEE Transactions on, vol. 51, pp. 859-863, 2004.
-
(2004)
Biomedical Engineering, IEEE Transactions on
, vol.51
, pp. 859-863
-
-
Martinoia, S.1
Massobrio, P.2
Bove, M.3
Massobrio, G.4
|