메뉴 건너뛰기




Volumn 7, Issue 2, 2008, Pages 139-149

Analysis of the ventilation system of an isolation room for a hospital

Author keywords

Air distribution; Bacterial contamination; Draught rating; Isolation room; Ventilation

Indexed keywords

BACTERIA; HOSPITALS; PATIENT TREATMENT; VENTILATION;

EID: 50549083704     PISSN: 14733315     EISSN: None     Source Type: Journal    
DOI: 10.1080/14733315.2008.11683806     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 0027694562 scopus 로고
    • Turbulent Dispersion of Particles: The STP Model
    • Baxter LL and Smith PJ: (1993) "Turbulent Dispersion of Particles: The STP Model", Energy & Fuels, 7, pp852-859.
    • (1993) Energy & Fuels , vol.7 , pp. 852-859
    • Baxter, L.L.1    Smith, P.J.2
  • 3
    • 0031183556 scopus 로고    scopus 로고
    • 0Using a mathematical model to evaluate the efficacy of TB control measures
    • Gammaitoni L and Nucci MC: (1997). "0Using a mathematical model to evaluate the efficacy of TB control measures", Emerging Infectious Diseases, 3, (3) pp335-342.
    • (1997) Emerging Infectious Diseases , vol.3 , Issue.3 , pp. 335-342
    • Gammaitoni, L.1    Nucci, M.C.2
  • 4
    • 0026225190 scopus 로고
    • Efficient statistical transport model for turbulent dispersion in sprays
    • Jeng SM and Litchford RJ: (1991) "Efficient statistical transport model for turbulent dispersion in sprays," AIAA Journal, 29, p1443.
    • (1991) AIAA Journal , vol.29 , pp. 1443
    • Jeng, S.M.1    Litchford, R.J.2
  • 5
    • 50549095794 scopus 로고    scopus 로고
    • HVAC for operation theatre and intensive care units: Comfort, air quality and energy utilization
    • Khalil E: (2005) "HVAC for operation theatre and intensive care units: Comfort, air quality and energy utilization", COMFEX; Ahmadabad, India.
    • (2005) COMFEX; Ahmadabad, India
    • Khalil, E.1
  • 6
    • 0032120750 scopus 로고    scopus 로고
    • Airborne respiratory diseases and mechanical systems for control of microbes
    • July
    • Kowalski WJ and Bahnfleth W: (1998) "Airborne respiratory diseases and mechanical systems for control of microbes", HPAC Engineering, July, 70, (7), pp34-48.
    • (1998) HPAC Engineering , vol.70 , Issue.7 , pp. 34-48
    • Kowalski, W.J.1    Bahnfleth, W.2
  • 9
    • 0034461709 scopus 로고    scopus 로고
    • Methodology for minimizing risk from airborne organisms in hospital isolation rooms
    • Memarzadeh F and Jiang J: (2000). "Methodology for minimizing risk from airborne organisms in hospital isolation rooms", ASHRAE Transactions, 106, (2), pp733-749.
    • (2000) ASHRAE Transactions , vol.106 , Issue.2 , pp. 733-749
    • Memarzadeh, F.1    Jiang, J.2
  • 11
    • 0008715161 scopus 로고
    • Numerical and experimental study on turbulent diffusion fields in conventional clean rooms
    • Murakami S, Kato S, Suyama Y. "Numerical and experimental study on turbulent diffusion fields in conventional clean rooms", ASHRAE Transactions 1988 94(2) pp 469-488.
    • (1988) ASHRAE Transactions , vol.94 , Issue.2 , pp. 469-488
    • Murakami, S.1    Kato, S.2    Suyama, Y.3
  • 12
    • 85089623804 scopus 로고    scopus 로고
    • Comparison of air exchange efficiency and contaminant removal effectiveness as IAQ indices
    • Novoselac A and Srebric J: (2003). "Comparison of air exchange efficiency and contaminant removal effectiveness as IAQ indices", ASHRAE Transactions, 94, (2), pp469-488.
    • (2003) ASHRAE Transactions , vol.94 , Issue.2 , pp. 469-488
    • Novoselac, A.1    Srebric, J.2
  • 13
    • 0142048870 scopus 로고
    • A re-evaluation of laminar air flow in hospital operating rooms
    • Phost JF: (1981) "A re-evaluation of laminar air flow in hospital operating rooms", ASHRAE Transactions, 87, (2), pp729-739.
    • (1981) ASHRAE Transactions , vol.87 , Issue.2 , pp. 729-739
    • Phost, J.F.1
  • 15
    • 0020940765 scopus 로고
    • The use of moments for assessing air quality in ventilated rooms
    • Sandberg M and Sjoberg M: (1983). "The use of moments for assessing air quality in ventilated rooms", Building and Environment, 18, (4), pp 181-197.
    • (1983) Building and Environment , vol.18 , Issue.4 , pp. 181-197
    • Sandberg, M.1    Sjoberg, M.2
  • 16
    • 2642572456 scopus 로고    scopus 로고
    • Diagonal air-distribution system for operating rooms: Experiment and modeling
    • Woloszyn M, Virgone J and Mélen S: (2004) "Diagonal air-distribution system for operating rooms: experiment and modeling", Building and Environment, 39, (10), pp 1171-1178.
    • (2004) Building and Environment , vol.39 , Issue.10 , pp. 1171-1178
    • Woloszyn, M.1    Virgone, J.2    Mélen, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.