메뉴 건너뛰기




Volumn 31, Issue 9, 2008, Pages 1152-1159

Cryoablation for atrioventricular nodal reentrant tachycardia in young patients: Predictors of recurrence

Author keywords

Atrioventricular node; Catheter ablation; Cryoablation; Pediatric; Recurrence; Reentry

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; ATRIOVENTRICULAR BLOCK; ATRIOVENTRICULAR JUNCTION ARRHYTHMIA; CHILD; CRYOABLATION; HEART CATHETERIZATION; HUMAN; MAJOR CLINICAL STUDY; RECURRENT DISEASE; TACHYCARDIA; TREATMENT OUTCOME;

EID: 50449090093     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2008.01156.x     Document Type: Article
Times cited : (54)

References (19)
  • 1
    • 15944369656 scopus 로고    scopus 로고
    • Transvenous cryothermal catheter ablation of re-entry circuit located near the atrioventricular junction in pediatric patients: Efficacy, safety, and midterm follow-up
    • Drago F, De Santis A, Grutter G, Silvetti MS. Transvenous cryothermal catheter ablation of re-entry circuit located near the atrioventricular junction in pediatric patients: Efficacy, safety, and midterm follow-up. J Am Coll Cardiol 2005 45 : 1096 1103.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1096-1103
    • Drago, F.1    De Santis, A.2    Grutter, G.3    Silvetti, M.S.4
  • 2
    • 11144240783 scopus 로고    scopus 로고
    • Transcatheter cryoablation of tachyarrhythmias in children: Initial experience from an international registry
    • Kirsh JA, Gross GJ, O'Connor S, Hamilton RM. Transcatheter cryoablation of tachyarrhythmias in children: Initial experience from an international registry. J Am Coll Cardiol 2005 45 : 133 136.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 133-136
    • Kirsh, J.A.1    Gross, G.J.2    O'Connor, S.3    Hamilton, R.M.4
  • 3
    • 32944475207 scopus 로고    scopus 로고
    • Efficacy and safety of cryoenergy in the ablation of atrioventricular reentrant tachycardia substrates in children and adolescents
    • Kriebel T, Broistedt C, Kroll M, Sigler M, Paul T. Efficacy and safety of cryoenergy in the ablation of atrioventricular reentrant tachycardia substrates in children and adolescents. J Cardiovasc Electrophysiol 2005 16 : 960 966.
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 960-966
    • Kriebel, T.1    Broistedt, C.2    Kroll, M.3    Sigler, M.4    Paul, T.5
  • 4
    • 13644271364 scopus 로고    scopus 로고
    • Cryo-ablation for septal tachycardia substrates in pediatric patients: Mid-term results
    • Miyazaki A, Blaufox AD, Fairbrother DL, Saul JP. Cryo-ablation for septal tachycardia substrates in pediatric patients: Mid-term results. J Am Coll Cardiol 2005 45 : 581 588.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 581-588
    • Miyazaki, A.1    Blaufox, A.D.2    Fairbrother, D.L.3    Saul, J.P.4
  • 5
    • 34547873098 scopus 로고    scopus 로고
    • Transvenous cryo-ablation of the slow pathway for the treatment of atrioventricular nodal re-entrant tachycardia: A single-centre initial experience study
    • De Sisti A, Tonet J, Barakett N, Lacotte J, Leclercq JF, Frank R. Transvenous cryo-ablation of the slow pathway for the treatment of atrioventricular nodal re-entrant tachycardia: A single-centre initial experience study. Europace 2007 9 : 906 908.
    • (2007) Europace , vol.9 , pp. 906-908
    • De Sisti, A.1    Tonet, J.2    Barakett, N.3    Lacotte, J.4    Leclercq, J.F.5    Frank, R.6
  • 6
    • 33845865243 scopus 로고    scopus 로고
    • Lengthier cryoablation and a bonus cryoapplication is associated with improved efficacy for cryothermal catheter ablation of supraventricular tachycardias in children
    • Drago F, Silvetti MS, De Santis A, Grutter G, Andrew P. Lengthier cryoablation and a bonus cryoapplication is associated with improved efficacy for cryothermal catheter ablation of supraventricular tachycardias in children. J Interv Card Electrophysiol 2006 16 : 191 198.
    • (2006) J Interv Card Electrophysiol , vol.16 , pp. 191-198
    • Drago, F.1    Silvetti, M.S.2    De Santis, A.3    Grutter, G.4    Andrew, P.5
  • 7
    • 33845502106 scopus 로고    scopus 로고
    • Cryoablation compared with radiofrequency ablation for atrioventricular nodal re-entrant tachycardia: Analysis of factors contributing to acute and follow-up outcome
    • Gupta D, Al-Lamee RK, Earley MJ, Kistler P, Harris SJ, Nathan AW, Sporton SC, Schilling RJ. Cryoablation compared with radiofrequency ablation for atrioventricular nodal re-entrant tachycardia: Analysis of factors contributing to acute and follow-up outcome. Europace 2006 8 : 1022 1026.
    • (2006) Europace , vol.8 , pp. 1022-1026
    • Gupta, D.1    Al-Lamee, R.K.2    Earley, M.J.3    Kistler, P.4    Harris, S.J.5    Nathan, A.W.6    Sporton, S.C.7    Schilling, R.J.8
  • 8
    • 33645962471 scopus 로고    scopus 로고
    • Cryoablation versus radiofrequency ablation for treatment of pediatric atrioventricular nodal reentrant tachycardia: Initial experience with 4-mm cryocatheter
    • Collins KK, Dubin AM, Chiesa NA, Avasarala K, Van Hare GF. Cryoablation versus radiofrequency ablation for treatment of pediatric atrioventricular nodal reentrant tachycardia: Initial experience with 4-mm cryocatheter. Heart Rhythm 2006 3 : 564 570.
    • (2006) Heart Rhythm , vol.3 , pp. 564-570
    • Collins, K.K.1    Dubin, A.M.2    Chiesa, N.A.3    Avasarala, K.4    Van Hare, G.F.5
  • 9
    • 38649134517 scopus 로고    scopus 로고
    • Cryoablation outcomes for AV nodal reentrant tachycardia comparing 4-mm versus 6-mm electrode-tip catheters
    • Rivard L, Dubuc M, Guerra PG, Novak P, Roy D, Macle L, Thibault B, et al. Cryoablation outcomes for AV nodal reentrant tachycardia comparing 4-mm versus 6-mm electrode-tip catheters. Heart Rhythm 2008 5 : 230 234.
    • (2008) Heart Rhythm , vol.5 , pp. 230-234
    • Rivard, L.1    Dubuc, M.2    Guerra, P.G.3    Novak, P.4    Roy, D.5    MacLe, L.6    Thibault, B.7
  • 10
    • 44649165958 scopus 로고    scopus 로고
    • Impact of cryoablation catheter size on success rates in the treatment of atrioventricular nodal re-entry tachycardia in 160 patients with long-term follow-up
    • Sandilands A, Boreham P, Pitts-Crick J, Cripps T. Impact of cryoablation catheter size on success rates in the treatment of atrioventricular nodal re-entry tachycardia in 160 patients with long-term follow-up. Europace 2008 10 : 683 686.
    • (2008) Europace , vol.10 , pp. 683-686
    • Sandilands, A.1    Boreham, P.2    Pitts-Crick, J.3    Cripps, T.4
  • 11
    • 33646002618 scopus 로고    scopus 로고
    • Cryoablation in pediatric atrioventricular nodal reentry: Electrophysiologic effects on atrioventricular nodal conduction
    • Collins KK, Dubin AM, Chiesa NA, McDaniel GM, Van Hare GF. Cryoablation in pediatric atrioventricular nodal reentry: Electrophysiologic effects on atrioventricular nodal conduction. Heart Rhythm 2006 3 : 557 563.
    • (2006) Heart Rhythm , vol.3 , pp. 557-563
    • Collins, K.K.1    Dubin, A.M.2    Chiesa, N.A.3    McDaniel, G.M.4    Van Hare, G.F.5
  • 12
    • 38849164708 scopus 로고    scopus 로고
    • Cryothermal slow pathway modification for atrioventricular nodal reentrant tachycardia
    • Khairy P, Novak PG, Guerra PG, Greiss I, Macle L, Roy D, Talajic M, et al. Cryothermal slow pathway modification for atrioventricular nodal reentrant tachycardia. Europace 2007 9 : 909 914.
    • (2007) Europace , vol.9 , pp. 909-914
    • Khairy, P.1    Novak, P.G.2    Guerra, P.G.3    Greiss, I.4    MacLe, L.5    Roy, D.6    Talajic, M.7
  • 13
    • 0028651867 scopus 로고
    • Radiofrequency ablation of slow pathway in patients with atrioventricular nodal reentrant tachycardia. Do arrhythmia recurrences correlate with persistent slow pathway conduction or site of successful ablation?
    • Manolis AS, Wang PJ, Estes NA, III. Radiofrequency ablation of slow pathway in patients with atrioventricular nodal reentrant tachycardia. Do arrhythmia recurrences correlate with persistent slow pathway conduction or site of successful ablation? Circulation 1994 90 : 2815 2819.
    • (1994) Circulation , vol.90 , pp. 2815-2819
    • Manolis, A.S.1    Wang, P.J.2    Estes, N.A.3    Iii4
  • 14
    • 0026526076 scopus 로고
    • Conversion of typical to "atypical" atrioventricular nodal reentrant tachycardia after radiofrequency catheter modification of the atrioventricular junction
    • Langberg JJ, Kim YN, Goyal R, Kou W, Calkins H, Sousa J, el-Atassi R, et al. Conversion of typical to "atypical" atrioventricular nodal reentrant tachycardia after radiofrequency catheter modification of the atrioventricular junction. A J Cardiol 1992 69 : 503 508.
    • (1992) A J Cardiol , vol.69 , pp. 503-508
    • Langberg, J.J.1    Kim, Y.N.2    Goyal, R.3    Kou, W.4    Calkins, H.5    Sousa, J.6    El-Atassi, R.7
  • 15
    • 27744481198 scopus 로고    scopus 로고
    • Prolongation of the fast pathway effective refractory period during cryoablation in children: A marker of slow pathway modification
    • Miyazaki A, Blaufox AD, Fairbrother DL, Saul JP. Prolongation of the fast pathway effective refractory period during cryoablation in children: A marker of slow pathway modification. Heart Rhythm 2005 2 : 1179 1185.
    • (2005) Heart Rhythm , vol.2 , pp. 1179-1185
    • Miyazaki, A.1    Blaufox, A.D.2    Fairbrother, D.L.3    Saul, J.P.4
  • 16
    • 23144467230 scopus 로고    scopus 로고
    • Catheter ablation of tachyarrhythmias in small children
    • Blaufox AD. Catheter ablation of tachyarrhythmias in small children. Indian Pacing Electrophysiol J 2005 5 : 51 62.
    • (2005) Indian Pacing Electrophysiol J , vol.5 , pp. 51-62
    • Blaufox, A.D.1
  • 17
    • 0033779095 scopus 로고    scopus 로고
    • Morphology of the human atrioventricular node is age dependent: A feature of potential clinical significance
    • Waki K, Kim JS, Becker AE. Morphology of the human atrioventricular node is age dependent: A feature of potential clinical significance. J Cardiovasc Electrophysiol 2000 11 : 1144 1151.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1144-1151
    • Waki, K.1    Kim, J.S.2    Becker, A.E.3
  • 19
    • 0037461289 scopus 로고    scopus 로고
    • Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation
    • Khairy P, Chauvet P, Lehmann J, Lambert J, Macle L, Tanguay JF, Sirois MG, et al. Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation. Circulation 2003 107 : 2045 2050.
    • (2003) Circulation , vol.107 , pp. 2045-2050
    • Khairy, P.1    Chauvet, P.2    Lehmann, J.3    Lambert, J.4    MacLe, L.5    Tanguay, J.F.6    Sirois, M.G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.