메뉴 건너뛰기




Volumn , Issue , 2007, Pages

Diagnosis of XLPE cable using the recovery voltage measurement method

Author keywords

Ageing; Diagnosis; Recovery voltage; RVM; XLPE cable

Indexed keywords

ELECTRIC MEASURING INSTRUMENTS; VOLTAGE MEASUREMENT;

EID: 50449088217     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SCORED.2007.4451441     Document Type: Conference Paper
Times cited : (8)

References (18)
  • 1
    • 0025403533 scopus 로고
    • Ageing characteristics of paper-insulated power cables
    • March
    • G. Robinson, "Ageing characteristics of paper-insulated power cables", IEE Power Engineering Journal, pp. 95-99, March 1990.
    • (1990) IEE Power Engineering Journal , pp. 95-99
    • Robinson, G.1
  • 4
    • 3242756597 scopus 로고    scopus 로고
    • Dielectric response measurements as diagnostic tool of power cable systems Helsinki University of Technology, High Voltage Institute
    • Report TKK-SJT-47, Espoo, pp
    • B. Oyegoke, P. Hyvonen and M. Aro, "Dielectric response measurements as diagnostic tool of power cable systems" Helsinki University of Technology, High Voltage Institute, Report TKK-SJT-47, Espoo, pp. 1 -24, 2001
    • (2001) , pp. 1-24
    • Oyegoke, B.1    Hyvonen, P.2    Aro, M.3
  • 5
    • 0344978176 scopus 로고
    • Proposed fundamental characteristics describing dielectric processes in dielectrics
    • Feb
    • E. Nemeth, "Proposed fundamental characteristics describing dielectric processes in dielectrics", Periodica Polytechnica Ser. Electrical Engineering, vol. 15, no. 4, pp. 305-322, Feb. 1971.
    • (1971) Periodica Polytechnica Ser. Electrical Engineering , vol.15 , Issue.4 , pp. 305-322
    • Nemeth, E.1
  • 6
    • 50449105096 scopus 로고    scopus 로고
    • Experience with dielectric response measurements on oil-paper insulated cables
    • Rotterdam, Netherlands, Millpress
    • T.K. Saha, J.H. Yew and P. Purkait , "Experience with dielectric response measurements on oil-paper insulated cables" XIIIth Int'l Symposium on High Voltage Engineering. Rotterdam, Netherlands, Millpress, 2003
    • (2003) XIIIth Int'l Symposium on High Voltage Engineering
    • Saha, T.K.1    Yew, J.H.2    Purkait, P.3
  • 7
    • 0033353280 scopus 로고    scopus 로고
    • Measuring voltage response: A non-destructive diagnostic test method of HV insulation
    • Sept
    • E. Nemeth, "Measuring voltage response: a non-destructive diagnostic test method of HV insulation" IEE Proceedings: Science, Measurement and Technology, vol. 146, no. 5, pp. 249-252, Sept. 1999.
    • (1999) IEE Proceedings: Science, Measurement and Technology , vol.146 , Issue.5 , pp. 249-252
    • Nemeth, E.1
  • 9
    • 0037971978 scopus 로고    scopus 로고
    • Voltage response measurements for power transformer moisture and ageing condition assessment
    • T.Z. Yao and T.K. Saha, "Voltage response measurements for power transformer moisture and ageing condition assessment", IEEE Transmission and Distribution Conf. And Exhibition, pp. 307-312, 2002.
    • (2002) IEEE Transmission and Distribution Conf. And Exhibition , pp. 307-312
    • Yao, T.Z.1    Saha, T.K.2
  • 11
    • 1842529229 scopus 로고    scopus 로고
    • Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers
    • Jan
    • T.K. Saha and P. Purkait, "Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers", IEEE Transactions on Dielectrics and Electrical Insulation, vol. 11, no. 1, pp. 144-154, Jan. 2004.
    • (2004) IEEE Transactions on Dielectrics and Electrical Insulation , vol.11 , Issue.1 , pp. 144-154
    • Saha, T.K.1    Purkait, P.2
  • 12
    • 84901740915 scopus 로고    scopus 로고
    • Investigating the impact of ageing and moisture on dielectric response of oil/paper insulation system
    • Rotterdam, Netherlands, Millpress
    • T.K. Saha and P. Purkait, "Investigating the impact of ageing and moisture on dielectric response of oil/paper insulation system", XIIIth Int'l Symposium on High Voltage Engineering. Rotterdam, Netherlands, Millpress, 2003.
    • (2003) XIIIth Int'l Symposium on High Voltage Engineering
    • Saha, T.K.1    Purkait, P.2
  • 15
    • 0037250619 scopus 로고    scopus 로고
    • Experience with return voltage measurements for assessing insulation conditions in service-aged transformers
    • Jan
    • T.K. Saha and Z.T. Yao, "Experience with return voltage measurements for assessing insulation conditions in service-aged transformers", IEEE Transactions on Power Delivery, vol. 18, no. 1, pp. 128-135, Jan. 2003
    • (2003) IEEE Transactions on Power Delivery , vol.18 , Issue.1 , pp. 128-135
    • Saha, T.K.1    Yao, Z.T.2
  • 16
    • 0035193608 scopus 로고    scopus 로고
    • th Int'l Conference on Solid Dielectrics, pp. 504-507.
    • th Int'l Conference on Solid Dielectrics, pp. 504-507.
  • 18
    • 50449085870 scopus 로고    scopus 로고
    • Voltage response measurements for the diagnosis of insulation condition in power transformer
    • T.K. Saha, A. Prasad and Z.T. Yao, "Voltage response measurements for the diagnosis of insulation condition in power transformer", Int'l Sym. on High Voltage Engineering, 1999.
    • (1999) Int'l Sym. on High Voltage Engineering
    • Saha, T.K.1    Prasad, A.2    Yao, Z.T.3