메뉴 건너뛰기




Volumn 16, Issue 4, 2004, Pages 271-276

ECG artifacts during intraoperative high-field MRI scanning

Author keywords

Electrocardiogram; Electrocardiographic artifacts; Intraoperative magnetic resonance imaging; Magnetic resonance imaging; Monitoring

Indexed keywords

PROPOFOL; REMIFENTANIL;

EID: 5044222453     PISSN: 08984921     EISSN: None     Source Type: Journal    
DOI: 10.1097/00008506-200410000-00002     Document Type: Article
Times cited : (26)

References (20)
  • 1
    • 0036836015 scopus 로고    scopus 로고
    • Low-field magnetic resonance imaging for intraoperative use in neurosurgery: A 5-year experience
    • Nimsky C, Ganslandt O, Tomandl B, et al. Low-field magnetic resonance imaging for intraoperative use in neurosurgery: a 5-year experience. Eur Radiol. 2002;12:2690-2703.
    • (2002) Eur Radiol , vol.12 , pp. 2690-2703
    • Nimsky, C.1    Ganslandt, O.2    Tomandl, B.3
  • 2
    • 0032611693 scopus 로고    scopus 로고
    • Anesthesiologic technical problems in procedures with open MRI. Results following 104 anesthesias
    • Laufer M, Schaffranietz L, Rudolph C, et al. Anesthesiologic technical problems in procedures with open MRI. Results following 104 anesthesias. Anaesthesist. 1999;48:51-56.
    • (1999) Anaesthesist , vol.48 , pp. 51-56
    • Laufer, M.1    Schaffranietz, L.2    Rudolph, C.3
  • 3
    • 0027984418 scopus 로고
    • ASA monitoring standards and magnetic resonance imaging
    • Jorgensen NH, Messick JM, Gray J, et al. ASA monitoring standards and magnetic resonance imaging. Anesth Analg. 1994;79:1141-1147.
    • (1994) Anesth Analg , vol.79 , pp. 1141-1147
    • Jorgensen, N.H.1    Messick, J.M.2    Gray, J.3
  • 4
    • 0026604572 scopus 로고
    • Anesthestic management for resonance imaging: Problems and solutions
    • Patteson SK, Chesney JT. Anesthestic management for resonance imaging: problems and solutions. Anesth Analg. 1992;74:121-128.
    • (1992) Anesth Analg , vol.74 , pp. 121-128
    • Patteson, S.K.1    Chesney, J.T.2
  • 5
    • 0038045169 scopus 로고    scopus 로고
    • Anesthesia during high-field intraoperative resonance imaging: Experience with eighty consecutive cases
    • Schmitz B, Nimsky C, Wendel G, et al. Anesthesia during high-field intraoperative resonance imaging: experience with eighty consecutive cases. J Neurosurg Anesth. 2003;15:215-226.
    • (2003) J Neurosurg Anesth , vol.15 , pp. 215-226
    • Schmitz, B.1    Nimsky, C.2    Wendel, G.3
  • 6
    • 3542996542 scopus 로고    scopus 로고
    • First clinical results of intraoperative high-field magnetic resonance imaging supported by neuronavigation
    • Lemke H, Vannier M, Inamura K, et al, eds. Amsterdam: Elsevier
    • Nimsky C, Ganslandt O, Keller v B, et al. First clinical results of intraoperative high-field magnetic resonance imaging supported by neuronavigation. In: Lemke H, Vannier M, Inamura K, et al, eds. CARS 2003. Amsterdam: Elsevier, 2003:601-606.
    • (2003) CARS 2003 , pp. 601-606
    • Nimsky, C.1    Ganslandt, O.2    Keller, V.B.3
  • 8
    • 0033228531 scopus 로고    scopus 로고
    • The AAPM/RSNA physics tutorial for residents
    • Price RR. The AAPM/RSNA physics tutorial for residents. Radiographies. 1999;19:1641-1651.
    • (1999) Radiographies , vol.19 , pp. 1641-1651
    • Price, R.R.1
  • 9
    • 0024730061 scopus 로고
    • ECG-alterations under the influence of static magnetic fields in nuclear magnetic tomography using magnets of field strength of 0,5 to 4,0 Tesla
    • Weikl A, Moshage W, Hentschel D, et al. ECG-alterations under the influence of static magnetic fields in nuclear magnetic tomography using magnets of field strength of 0,5 to 4,0 Tesla. Z Kardiolog. 1989;78:578-586.
    • (1989) Z Kardiolog , vol.78 , pp. 578-586
    • Weikl, A.1    Moshage, W.2    Hentschel, D.3
  • 10
    • 0030222301 scopus 로고    scopus 로고
    • Burns associated with electrographic monitoring during magnetic resonance imaging
    • Jones S, Jaffe W, Alvi R. Burns associated with electrographic monitoring during magnetic resonance imaging. Burns. 1996;22:420-421.
    • (1996) Burns , vol.22 , pp. 420-421
    • Jones, S.1    Jaffe, W.2    Alvi, R.3
  • 11
    • 0035383751 scopus 로고    scopus 로고
    • Thermal injuries associated with MRI
    • Dempsey MF, Condon B. Thermal injuries associated with MRI. Clin Radiol. 2001;56:457-465.
    • (2001) Clin Radiol , vol.56 , pp. 457-465
    • Dempsey, M.F.1    Condon, B.2
  • 12
    • 0035085031 scopus 로고    scopus 로고
    • Investigation of the factors responsible for burns during MRI
    • Dempsey MF, Condon B, Hadley DM. Investigation of the factors responsible for burns during MRI. Magn Res Imag. 2001;13:627-631.
    • (2001) Magn Res Imag , vol.13 , pp. 627-631
    • Dempsey, M.F.1    Condon, B.2    Hadley, D.M.3
  • 13
    • 0030340334 scopus 로고    scopus 로고
    • Burns caused by ECG monitoring during MRI imaging
    • Keens SJ, Laurence AS. Burns caused by ECG monitoring during MRI imaging. Anesthesia. 1996;51:1188-1189.
    • (1996) Anesthesia , vol.51 , pp. 1188-1189
    • Keens, S.J.1    Laurence, A.S.2
  • 14
    • 0035064547 scopus 로고    scopus 로고
    • Intraoperative magnetic resonance imaging combined with neuronavigation: A new concept
    • Nimsky C, Ganslandt O, Kober H, et al. Intraoperative magnetic resonance imaging combined with neuronavigation: a new concept. Neurosurgery. 2001;48:1082-1091.
    • (2001) Neurosurgery , vol.48 , pp. 1082-1091
    • Nimsky, C.1    Ganslandt, O.2    Kober, H.3
  • 15
    • 0033753708 scopus 로고    scopus 로고
    • Quantification of, visualization of, and compensation for brain shift using intraoperative magnetic resonance imaging
    • Nimsky C, Ganslandt O, Cerny S, et al. Quantification of, visualization of, and compensation for brain shift using intraoperative magnetic resonance imaging. Neurosurgery. 2000;47:1070-1080.
    • (2000) Neurosurgery , vol.47 , pp. 1070-1080
    • Nimsky, C.1    Ganslandt, O.2    Cerny, S.3
  • 16
    • 0035085319 scopus 로고    scopus 로고
    • Anesthesia for magnetic resonance guided neurosurgery: Initial experience with a new open magnetic resonance imaging system
    • Berkenstadt H, Perel A, Ram Z, et al. Anesthesia for magnetic resonance guided neurosurgery: initial experience with a new open magnetic resonance imaging system. J Neurosurg Anesthesiol. 2001;13:158-162.
    • (2001) J Neurosurg Anesthesiol , vol.13 , pp. 158-162
    • Berkenstadt, H.1    Perel, A.2    Ram, Z.3
  • 17
    • 0036247392 scopus 로고    scopus 로고
    • Anesthesia in the magnetic resonance unit: A hazardous environment
    • Farling PA. Anesthesia in the magnetic resonance unit: a hazardous environment. Anesthesia. 2002;57:421-423.
    • (2002) Anesthesia , vol.57 , pp. 421-423
    • Farling, P.A.1
  • 18
    • 0034264482 scopus 로고    scopus 로고
    • Exposure to strong ELF magnetic fields does not alter cardiac autonomic control mechanisms
    • Graham C, Sastre A, Cook MR, et al. Exposure to strong ELF magnetic fields does not alter cardiac autonomic control mechanisms. Bioelectromagnetics. 2000;21:413-421.
    • (2000) Bioelectromagnetics , vol.21 , pp. 413-421
    • Graham, C.1    Sastre, A.2    Cook, M.R.3
  • 19
    • 0027431317 scopus 로고
    • Invasive pressure monitoring of patients during magnetic resonance imaging
    • Taber KH, Thompson J, Coveler LA, et al. Invasive pressure monitoring of patients during magnetic resonance imaging. Can J Anesth. 1993;40:1092-1095.
    • (1993) Can J Anesth , vol.40 , pp. 1092-1095
    • Taber, K.H.1    Thompson, J.2    Coveler, L.A.3
  • 20
    • 0028524876 scopus 로고
    • Electrocardiogram aquisition during MR examinations for patient monitoring and sequence triggering
    • Felblinger J, Lehmann C, Boesch C. Electrocardiogram aquisition during MR examinations for patient monitoring and sequence triggering. Mag Res Med. 1994;32:523-529.
    • (1994) Mag Res Med , vol.32 , pp. 523-529
    • Felblinger, J.1    Lehmann, C.2    Boesch, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.