메뉴 건너뛰기




Volumn 19, Issue 5, 2004, Pages 230-236

FX minirail balloon angioplasty for the treatment of patients with in-stent restenosis: A matched comparison of 6 months' outcome with conventional balloon angioplasty

Author keywords

Conventional percutaneous transluminal balloon angioplasty; FX minirail balloon; In stent restenosis

Indexed keywords

ACETYLSALICYLIC ACID; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CALCIUM ANTAGONIST; CLOPIDOGREL; CORASPIN; HEPARIN; HYDROXYMETHYLGLUTARYL COENZYME A REDUCTASE INHIBITOR; LIQUEMINE; NITRIC ACID DERIVATIVE; TIROFIBAN;

EID: 5044220921     PISSN: 09108327     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00380-004-0773-9     Document Type: Article
Times cited : (3)

References (25)
  • 3
    • 0035112671 scopus 로고    scopus 로고
    • Prevention of restenosis after percutaneous coronary interventions
    • Jan/Feb
    • Lubbe DF, Holmes DR (2001) Prevention of restenosis after percutaneous coronary interventions. ACC Curr J Rev Jan/Feb: 39-42
    • (2001) ACC Curr. J. Rev. , pp. 39-42
    • Lubbe, D.F.1    Holmes, D.R.2
  • 6
    • 0019559720 scopus 로고
    • Percutaneous transluminal coronary angioplasty
    • Gruentzig AR (1981) Percutaneous transluminal coronary angioplasty. Semin Roentgenol 16:152-153
    • (1981) Semin. Roentgenol. , vol.16 , pp. 152-153
    • Gruentzig, A.R.1
  • 7
    • 5044236932 scopus 로고
    • Pathologic findings after percutaneous transluminal angioplasty
    • Mizuno K, Jurital A, Imazeki N (1984) Pathologic findings after percutaneous transluminal angioplasty. Br Heart J 18:476-484
    • (1984) Br. Heart J. , vol.18 , pp. 476-484
    • Mizuno, K.1    Jurital, A.2    Imazeki, N.3
  • 8
    • 0006148223 scopus 로고    scopus 로고
    • The pathophysiology and treatment of in-stent restenosis
    • Belder A, Thomas M (1998) The pathophysiology and treatment of in-stent restenosis. Stent 1:74-82
    • (1998) Stent , vol.1 , pp. 74-82
    • Belder, A.1    Thomas, M.2
  • 9
    • 0036900030 scopus 로고    scopus 로고
    • Clinical and angiographic outcome after conventional angioplasty with optional stent implantation compared with direct stenting without predilatation
    • Miketic S, Carlsson J, Tebbe U (2002) Clinical and angiographic outcome after conventional angioplasty with optional stent implantation compared with direct stenting without predilatation. Heart 88:622-626
    • (2002) Heart , vol.88 , pp. 622-626
    • Miketic, S.1    Carlsson, J.2    Tebbe, U.3
  • 10
    • 0024393107 scopus 로고
    • Restenosis after coronary angioplasty: Potential biologic determinants and role of intimal hyperplasia
    • Liu MW, Roubin GS, King SB (1989) Restenosis after coronary angioplasty: potential biologic determinants and role of intimal hyperplasia. Circulation 79:1374-1386
    • (1989) Circulation , vol.79 , pp. 1374-1386
    • Liu, M.W.1    Roubin, G.S.2    King, S.B.3
  • 11
  • 13
    • 0021998408 scopus 로고
    • Balloon angioplasty: Natural history of the pathophysiological response to injury in a pig model
    • Steele PM, Chesebro JH, Stanson AW (1985) Balloon angioplasty: natural history of the pathophysiological response to injury in a pig model. Circ Res 57:105-112
    • (1985) Circ. Res. , vol.57 , pp. 105-112
    • Steele, P.M.1    Chesebro, J.H.2    Stanson, A.W.3
  • 15
    • 0028240007 scopus 로고
    • Strain measurements in cultured vascular smooth muscle cells subjected to mechanical deformation
    • Barbee KA, Macarak EJ, Thibault LE (1994) Strain measurements in cultured vascular smooth muscle cells subjected to mechanical deformation. Ann Biomed Eng 22:14-22
    • (1994) Ann. Biomed. Eng. , vol.22 , pp. 14-22
    • Barbee, K.A.1    Macarak, E.J.2    Thibault, L.E.3
  • 16
    • 0028266292 scopus 로고
    • A randomized comparison of the effects of gradual prolonged versus standard primary balloon inflation on early and late outcome. Results of a multicenter clinical trial
    • Perfusion Balloon Catheter Study Group
    • Ohman EM, Marquis JF, Ricci DR, Brown RI, Knudtson ML, Kereiakes DJ, Samaha JK, Margolis JR, Niederman AL, Dean LS, et al (1994) A randomized comparison of the effects of gradual prolonged versus standard primary balloon inflation on early and late outcome. Results of a multicenter clinical trial. Perfusion Balloon Catheter Study Group. Circulation 89:1118-1125
    • (1994) Circulation , vol.89 , pp. 1118-1125
    • Ohman, E.M.1    Marquis, J.F.2    Ricci, D.R.3    Brown, R.I.4    Knudtson, M.L.5    Kereiakes, D.J.6    Samaha, J.K.7    Margolis, J.R.8    Niederman, A.L.9    Dean, L.S.10
  • 17
  • 18
    • 0019265325 scopus 로고
    • Coronary artery incision and dilation
    • Lary B (1980) Coronary artery incision and dilation. Arch Surg 115:1478-1480
    • (1980) Arch. Surg. , vol.115 , pp. 1478-1480
    • Lary, B.1
  • 19
    • 14444275200 scopus 로고    scopus 로고
    • Microsurgical dilation concept: Animal data
    • Barath P (1996) Microsurgical dilation concept: animal data. J Invas Cardiol 8:2-5
    • (1996) J. Invas. Cardiol. , vol.8 , pp. 2-5
    • Barath, P.1
  • 20
    • 0034857558 scopus 로고    scopus 로고
    • Cutting balloon angioplasty for the treatment of in-stent restenosis: A matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty
    • Adamian M, Colombo A, Briguori C, Nishida T, Marsico F, Di Mario C, Albiero R, Moussa I, Moses JW (2001) Cutting balloon angioplasty for the treatment of in-stent restenosis: a matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty. J Am Coll Cardiol 38:672-679
    • (2001) J. Am. Coll. Cardiol. , vol.38 , pp. 672-679
    • Adamian, M.1    Colombo, A.2    Briguori, C.3    Nishida, T.4    Marsico, F.5    Di Mario, C.6    Albiero, R.7    Moussa, I.8    Moses, J.W.9
  • 21
    • 0036710611 scopus 로고    scopus 로고
    • Comparison of volumetric intravascular ultrasound analysis of acute results and underlying mechanism from cutting balloon and conventional balloon angioplasty for the treatment of coronary in-stent restenotic lesions
    • Schiele TM, König A, Rieber J, Theisen K, Siebert U, Klauss V (2002) Comparison of volumetric intravascular ultrasound analysis of acute results and underlying mechanism from cutting balloon and conventional balloon angioplasty for the treatment of coronary in-stent restenotic lesions. Am J Cardiol 90:539-542
    • (2002) Am. J. Cardiol. , vol.90 , pp. 539-542
    • Schiele, T.M.1    König, A.2    Rieber, J.3    Theisen, K.4    Siebert, U.5    Klauss, V.6
  • 23
    • 0036606901 scopus 로고    scopus 로고
    • Intravascular ultrasonic comparison of mechanism of vasodilatation of cutting balloon angioplasty versus conventional balloon angioplasty
    • Hara H, Nakamura M, Asahura T, Nishida T, Yamaguchi T (2002) Intravascular ultrasonic comparison of mechanism of vasodilatation of cutting balloon angioplasty versus conventional balloon angioplasty. Am J Cardiol 89:1253-1256
    • (2002) Am. J. Cardiol. , vol.89 , pp. 1253-1256
    • Hara, H.1    Nakamura, M.2    Asahura, T.3    Nishida, T.4    Yamaguchi, T.5
  • 24
    • 0035500034 scopus 로고    scopus 로고
    • Intravascular ultrasound assessment of the mechanism of lumen enlargement during cutting balloon angioplasty treatment of in-stent restenosis
    • Ahmed JM, Mintz GS, Castogna M, Weissman NJ, Pichard AD, Satler LF, Kent KM (2001) Intravascular ultrasound assessment of the mechanism of lumen enlargement during cutting balloon angioplasty treatment of in-stent restenosis. Am J Cardiol 88:1032-1034
    • (2001) Am. J. Cardiol. , vol.88 , pp. 1032-1034
    • Ahmed, J.M.1    Mintz, G.S.2    Castogna, M.3    Weissman, N.J.4    Pichard, A.D.5    Satler, L.F.6    Kent, K.M.7
  • 25
    • 5044225470 scopus 로고    scopus 로고
    • First clinical experience with the FX minirail catheter: A novel device for the enhancement of percutaneous coronary intervention in de novo and restenostic lesions
    • (abstract)
    • Almagor Y, Meerkin D, Solar R, Ischinger T (2002) First clinical experience with the FX minirail catheter: a novel device for the enhancement of percutaneous coronary intervention in de novo and restenostic lesions (abstract). Eur Heart J 23 (suppl A): 553
    • (2002) Eur. Heart J. , vol.23 , Issue.SUPPL. A , pp. 553
    • Almagor, Y.1    Meerkin, D.2    Solar, R.3    Ischinger, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.