메뉴 건너뛰기




Volumn 40, Issue 11, 2008, Pages 2083-2089

The impact of thermal bridges on the energy demand of buildings with double brick wall constructions

Author keywords

Double brick walls; Insulation; Thermal bridges; Thermal facade

Indexed keywords

BRIDGES; BUILDINGS; CONSERVATION; EFFICIENCY; ENERGY CONSERVATION; ENERGY EFFICIENCY; ENERGY MANAGEMENT; ENERGY POLICY; INSULATION; LAWS AND LEGISLATION; PAPER; WALLS (STRUCTURAL PARTITIONS);

EID: 50349094126     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2008.06.006     Document Type: Article
Times cited : (166)

References (16)
  • 1
    • 50349098318 scopus 로고    scopus 로고
    • European Commission, Directive 2002/91/EC of the European Parliament and of the Council of 16th December 2002 on the energy performance of buildings, OJEC, L1/65, 04/01/2003.
    • European Commission, Directive 2002/91/EC of the European Parliament and of the Council of 16th December 2002 on the energy performance of buildings, OJEC, L1/65, 04/01/2003.
  • 3
    • 23744507276 scopus 로고    scopus 로고
    • Statistical modelling of heat transfer for thermal bridges of buildings
    • Larbi A.B. Statistical modelling of heat transfer for thermal bridges of buildings. Energy and Buildings 37 (2005) 945-951
    • (2005) Energy and Buildings , vol.37 , pp. 945-951
    • Larbi, A.B.1
  • 4
    • 0035400744 scopus 로고    scopus 로고
    • Effect of 2D modelling of thermal bridges on the energy performance of buildings: numerical application on the Matisse apartment
    • Déqué F., Ollivier F., and Roux J.J. Effect of 2D modelling of thermal bridges on the energy performance of buildings: numerical application on the Matisse apartment. Energy and Buildings 33 (2001) 583-587
    • (2001) Energy and Buildings , vol.33 , pp. 583-587
    • Déqué, F.1    Ollivier, F.2    Roux, J.J.3
  • 6
    • 0036788944 scopus 로고    scopus 로고
    • Applying the building energy simulation test (BESTEST) diagnostic method to verification of space conditioning equipment models used in whole-building energy simulation programs
    • Neymark J., Judkoff R., Knabe G., Le H.-T., Durig M., Glass A., and Zweifel G. Applying the building energy simulation test (BESTEST) diagnostic method to verification of space conditioning equipment models used in whole-building energy simulation programs. Energy and Buildings 34 (2002) p.917-931
    • (2002) Energy and Buildings , vol.34
    • Neymark, J.1    Judkoff, R.2    Knabe, G.3    Le, H.-T.4    Durig, M.5    Glass, A.6    Zweifel, G.7
  • 7
    • 0003678867 scopus 로고    scopus 로고
    • Solar Energy Laboratory, University of Wisconsin, Madison, WI
    • TRNSYS. A Transient System Simulation Program (2006), Solar Energy Laboratory, University of Wisconsin, Madison, WI
    • (2006) A Transient System Simulation Program
    • TRNSYS1
  • 11
    • 0036604734 scopus 로고    scopus 로고
    • Multi-dimensional heat transfer through complex building envelope assemblies in hourly energy simulation programs
    • Kosny J., and Kossecka E. Multi-dimensional heat transfer through complex building envelope assemblies in hourly energy simulation programs. Energy and Buildings 34 (2002) 445-454
    • (2002) Energy and Buildings , vol.34 , pp. 445-454
    • Kosny, J.1    Kossecka, E.2
  • 12
    • 29144436238 scopus 로고    scopus 로고
    • Thermal performance benefits of precast concrete panel and insulated concrete form technologies for residential construction
    • Doebber I., and Ellis M. Thermal performance benefits of precast concrete panel and insulated concrete form technologies for residential construction. ASHRAE Trans 111 (2005) 340-352
    • (2005) ASHRAE Trans , vol.111 , pp. 340-352
    • Doebber, I.1    Ellis, M.2
  • 13
    • 50349092177 scopus 로고    scopus 로고
    • SAPPEK, Development of innovative insulation elements based on stone wool, Project report, vol. 1, Lab. of Heat Transfer and Environmental Engineering, Aristotle University Thessaloniki, 2007 (in Greek).
    • SAPPEK, Development of innovative insulation elements based on stone wool, Project report, vol. 1, Lab. of Heat Transfer and Environmental Engineering, Aristotle University Thessaloniki, 2007 (in Greek).
  • 15
    • 0036604728 scopus 로고    scopus 로고
    • Feasibility of energy saving renovation measures in urban buildings: the impact of energy prices and the acceptable pay back time criterion
    • Papadopoulos A.M., Theodosiou T., and Karatzas K. Feasibility of energy saving renovation measures in urban buildings: the impact of energy prices and the acceptable pay back time criterion. Energy and Buildings 34 (2002) 455-466
    • (2002) Energy and Buildings , vol.34 , pp. 455-466
    • Papadopoulos, A.M.1    Theodosiou, T.2    Karatzas, K.3
  • 16
    • 37349001728 scopus 로고    scopus 로고
    • Energy, economic and environmental performance of heating systems used in Greek buildings
    • Papadopoulos A.M., Oxizidis S., and Papandritsas G. Energy, economic and environmental performance of heating systems used in Greek buildings. Energy and Buildings 40 (2008) 224-230
    • (2008) Energy and Buildings , vol.40 , pp. 224-230
    • Papadopoulos, A.M.1    Oxizidis, S.2    Papandritsas, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.