메뉴 건너뛰기




Volumn 86, Issue 1, 2009, Pages 52-59

Numerical analysis of effect of shape-stabilized phase change material plates in a building combined with night ventilation

Author keywords

Latent heat thermal energy storage; Night ventilation; Shape stabilized phase change material

Indexed keywords

AIR CONDITIONING; HEAT STORAGE; PASSIVE SOLAR BUILDINGS; PLATES (STRUCTURAL COMPONENTS); THERMAL CONDUCTIVITY; THERMODYNAMIC PROPERTIES; VENTILATION;

EID: 50349083954     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2008.03.020     Document Type: Article
Times cited : (119)

References (34)
  • 2
    • 0022562488 scopus 로고
    • Thermal analysis of naturally ventilated buildings
    • Mathews E.H. Thermal analysis of naturally ventilated buildings. Build Environ 21 1 (1986) 35-39
    • (1986) Build Environ , vol.21 , Issue.1 , pp. 35-39
    • Mathews, E.H.1
  • 3
    • 0032098962 scopus 로고    scopus 로고
    • Summer cooling with night ventilation for office buildings in moderate climates
    • Kolokotroni M., and Webb B.C. Summer cooling with night ventilation for office buildings in moderate climates. Energy Build 27 3 (1998) 231-237
    • (1998) Energy Build , vol.27 , Issue.3 , pp. 231-237
    • Kolokotroni, M.1    Webb, B.C.2
  • 5
    • 33745037453 scopus 로고    scopus 로고
    • Application of night cooling concept to social housing design in dry hot climate
    • Macias M., Mateo A., Schuler M., and Mitre E.M. Application of night cooling concept to social housing design in dry hot climate. Energy Build 38 9 (2006) 1104-1110
    • (2006) Energy Build , vol.38 , Issue.9 , pp. 1104-1110
    • Macias, M.1    Mateo, A.2    Schuler, M.3    Mitre, E.M.4
  • 6
    • 34248201223 scopus 로고    scopus 로고
    • Sensitivity analysis of a maritime located night ventilated library building
    • Finn D.P., Connolly D., and Kenny P. Sensitivity analysis of a maritime located night ventilated library building. Sol Energy 81 6 (2007) 697-710
    • (2007) Sol Energy , vol.81 , Issue.6 , pp. 697-710
    • Finn, D.P.1    Connolly, D.2    Kenny, P.3
  • 7
    • 0031281983 scopus 로고    scopus 로고
    • Night ventilation for building cooling in summer
    • Blondeau P., Sperandio M., and Allard F. Night ventilation for building cooling in summer. Sol Energy 61 5 (1997) 327-335
    • (1997) Sol Energy , vol.61 , Issue.5 , pp. 327-335
    • Blondeau, P.1    Sperandio, M.2    Allard, F.3
  • 8
    • 0032141520 scopus 로고    scopus 로고
    • Effectiveness of mass and night ventilation in lowering the indoor daytime temperatures. Part I: 1993 experimental periods
    • Givoni B. Effectiveness of mass and night ventilation in lowering the indoor daytime temperatures. Part I: 1993 experimental periods. Energy Build 28 1 (1998) 25-32
    • (1998) Energy Build , vol.28 , Issue.1 , pp. 25-32
    • Givoni, B.1
  • 9
    • 0033311825 scopus 로고    scopus 로고
    • Cooling energy reduction in air conditioned offices by using night ventilation
    • Kolokotroni M., and Aronis A. Cooling energy reduction in air conditioned offices by using night ventilation. Appl Energy 63 4 (1999) 241-253
    • (1999) Appl Energy , vol.63 , Issue.4 , pp. 241-253
    • Kolokotroni, M.1    Aronis, A.2
  • 10
    • 0034817698 scopus 로고    scopus 로고
    • Night ventilation cooling of office buildings: parametric analyses of conceptual energy impacts
    • Kolokotroni M. Night ventilation cooling of office buildings: parametric analyses of conceptual energy impacts. ASHRAE Trans 107 1 (2001) 479-489
    • (2001) ASHRAE Trans , vol.107 , Issue.1 , pp. 479-489
    • Kolokotroni, M.1
  • 11
    • 0033990741 scopus 로고    scopus 로고
    • Improving night ventilation into low-rise buildings in hot-arid climates exploring a combined wall-roof solar chimney
    • AboulNaga M.M. Improving night ventilation into low-rise buildings in hot-arid climates exploring a combined wall-roof solar chimney. Renew Energy 19 1-2 (2000) 47-54
    • (2000) Renew Energy , vol.19 , Issue.1-2 , pp. 47-54
    • AboulNaga, M.M.1
  • 12
    • 0035502240 scopus 로고    scopus 로고
    • Thermal mass and night ventilation as passive cooling design strategy
    • Shaviv E., Yezioro A., and Capeluto I.G. Thermal mass and night ventilation as passive cooling design strategy. Renew Energy 24 3-4 (2001) 445-452
    • (2001) Renew Energy , vol.24 , Issue.3-4 , pp. 445-452
    • Shaviv, E.1    Yezioro, A.2    Capeluto, I.G.3
  • 13
    • 0037365219 scopus 로고    scopus 로고
    • Nonlinear coupling between thermal mass and natural ventilation in buildings
    • Yam J., Li Y.G., and Zheng Z.H. Nonlinear coupling between thermal mass and natural ventilation in buildings. Int J Heat Mass Transfer 46 7 (2003) 1251-1264
    • (2003) Int J Heat Mass Transfer , vol.46 , Issue.7 , pp. 1251-1264
    • Yam, J.1    Li, Y.G.2    Zheng, Z.H.3
  • 15
    • 33745347383 scopus 로고    scopus 로고
    • Ideal thermal physical properties for free-cooling (or heating) buildings with constant thermal physical property material
    • Zhang Y.P., Lin K.P., Zhang Q.L., and Di H.F. Ideal thermal physical properties for free-cooling (or heating) buildings with constant thermal physical property material. Energy Build 38 10 (2006) 1164-1170
    • (2006) Energy Build , vol.38 , Issue.10 , pp. 1164-1170
    • Zhang, Y.P.1    Lin, K.P.2    Zhang, Q.L.3    Di, H.F.4
  • 16
    • 33847018738 scopus 로고    scopus 로고
    • Application of latent heat thermal energy storage in buildings: state-of-the-art and outlook
    • Zhang Y.P., Zhou G.B., Lin K.P., Zhang Q.L., and Di H.F. Application of latent heat thermal energy storage in buildings: state-of-the-art and outlook. Build Environ 42 6 (2007) 2197-2209
    • (2007) Build Environ , vol.42 , Issue.6 , pp. 2197-2209
    • Zhang, Y.P.1    Zhou, G.B.2    Lin, K.P.3    Zhang, Q.L.4    Di, H.F.5
  • 17
    • 10044257361 scopus 로고    scopus 로고
    • Free-cooling of buildings with phase change materials
    • Zalba B., Marin J.M., Cabeza L.F., and Mehling H. Free-cooling of buildings with phase change materials. Int J Refrig 27 8 (2004) 839-849
    • (2004) Int J Refrig , vol.27 , Issue.8 , pp. 839-849
    • Zalba, B.1    Marin, J.M.2    Cabeza, L.F.3    Mehling, H.4
  • 18
    • 0033727740 scopus 로고    scopus 로고
    • Novel ventilation system for reducing air conditioning in buildings: testing and theoretical modeling
    • Turnpenny J.R., Etheridge D.W., and Reay D.A. Novel ventilation system for reducing air conditioning in buildings: testing and theoretical modeling. Appl Therm Eng 20 11 (2000) 1019-1037
    • (2000) Appl Therm Eng , vol.20 , Issue.11 , pp. 1019-1037
    • Turnpenny, J.R.1    Etheridge, D.W.2    Reay, D.A.3
  • 19
    • 0035427464 scopus 로고    scopus 로고
    • Novel ventilation system for reducing air conditioning in buildings: testing of prototype
    • Turnpenny J.R., Etheridge D.W., and Reay D.A. Novel ventilation system for reducing air conditioning in buildings: testing of prototype. Appl Therm Eng 21 12 (2001) 1203-1217
    • (2001) Appl Therm Eng , vol.21 , Issue.12 , pp. 1203-1217
    • Turnpenny, J.R.1    Etheridge, D.W.2    Reay, D.A.3
  • 20
    • 0035254762 scopus 로고    scopus 로고
    • Analysis and modelling of a phase change storage system for air conditioning applications
    • Vakilaltojjar S.M., and Saman W. Analysis and modelling of a phase change storage system for air conditioning applications. Appl Therm Eng 21 3 (2001) 249-263
    • (2001) Appl Therm Eng , vol.21 , Issue.3 , pp. 249-263
    • Vakilaltojjar, S.M.1    Saman, W.2
  • 22
    • 24344483870 scopus 로고    scopus 로고
    • Feasibility analysis on phase change cooling storage in large day-and-night temperature difference area
    • [in Chinese]
    • Feng G.H., Cao G.Y., Yu J., Chen X.D., and Hu Y.J. Feasibility analysis on phase change cooling storage in large day-and-night temperature difference area. J Shenyang Jianzhu Univ (Nat Sci) 21 4 (2005) 350-353 [in Chinese]
    • (2005) J Shenyang Jianzhu Univ (Nat Sci) , vol.21 , Issue.4 , pp. 350-353
    • Feng, G.H.1    Cao, G.Y.2    Yu, J.3    Chen, X.D.4    Hu, Y.J.5
  • 23
    • 0031124279 scopus 로고    scopus 로고
    • Evaluation of thermophysical characteristics on shape-stabilized paraffin as a solid-liquid phase change material
    • Inaba H., and Tu P. Evaluation of thermophysical characteristics on shape-stabilized paraffin as a solid-liquid phase change material. Heat Mass Transfer 32 4 (1997) 307-312
    • (1997) Heat Mass Transfer , vol.32 , Issue.4 , pp. 307-312
    • Inaba, H.1    Tu, P.2
  • 24
    • 0034259291 scopus 로고    scopus 로고
    • Preparation of polyethylene-paraffin compound as a form-stable solid-liquid phase change material
    • Ye H., and Ge X.S. Preparation of polyethylene-paraffin compound as a form-stable solid-liquid phase change material. Sol Energy Mater Sol Cells 64 1 (2000) 37-44
    • (2000) Sol Energy Mater Sol Cells , vol.64 , Issue.1 , pp. 37-44
    • Ye, H.1    Ge, X.S.2
  • 25
    • 0036027768 scopus 로고    scopus 로고
    • Preparation and performance of shape stabilized phase change thermal storage materials with high thermal conductivity
    • Xiao M., Feng B., and Gong K.C. Preparation and performance of shape stabilized phase change thermal storage materials with high thermal conductivity. Energy Convers Manage 43 1 (2002) 103-108
    • (2002) Energy Convers Manage , vol.43 , Issue.1 , pp. 103-108
    • Xiao, M.1    Feng, B.2    Gong, K.C.3
  • 26
    • 33745371048 scopus 로고    scopus 로고
    • Preparation, thermal performance and application of shape-stabilized PCM in energy efficient buildings
    • Zhang Y.P., Lin K.P., Yang R., Di H.F., and Jiang Y. Preparation, thermal performance and application of shape-stabilized PCM in energy efficient buildings. Energy Build 38 10 (2006) 1262-1269
    • (2006) Energy Build , vol.38 , Issue.10 , pp. 1262-1269
    • Zhang, Y.P.1    Lin, K.P.2    Yang, R.3    Di, H.F.4    Jiang, Y.5
  • 27
    • 33646062896 scopus 로고    scopus 로고
    • Influence of additives on thermal conductivity of shape-stabilized phase change materials
    • Zhang Y.P., Ding J.H., Yang R., and Wang X. Influence of additives on thermal conductivity of shape-stabilized phase change materials. Sol Energy Mater Sol Cells 90 11 (2006) 1692-1702
    • (2006) Sol Energy Mater Sol Cells , vol.90 , Issue.11 , pp. 1692-1702
    • Zhang, Y.P.1    Ding, J.H.2    Yang, R.3    Wang, X.4
  • 28
    • 23844496489 scopus 로고    scopus 로고
    • Modeling and simulation on the thermal performance of shape-stabilized phase change material floor used in passive solar buildings
    • Xu X., Zhang Y.P., Lin K.P., Di H.F., and Yang R. Modeling and simulation on the thermal performance of shape-stabilized phase change material floor used in passive solar buildings. Energy Build 37 (2005) 1084-1091
    • (2005) Energy Build , vol.37 , pp. 1084-1091
    • Xu, X.1    Zhang, Y.P.2    Lin, K.P.3    Di, H.F.4    Yang, R.5
  • 29
    • 84881326461 scopus 로고    scopus 로고
    • Wu RH, Jiang Y. Medpha - Meteorological Data producer for HVAC analysis. Version 1.0. Tsinghua Artificial Environment Co., Beijing, China, 1997.
    • Wu RH, Jiang Y. Medpha - Meteorological Data producer for HVAC analysis. Version 1.0. Tsinghua Artificial Environment Co., Beijing, China, 1997.
  • 30
    • 39349102924 scopus 로고    scopus 로고
    • Thermal analysis of a direct gain room with shape-stabilized PCM plates
    • Zhou G.B., Zhang Y.P., Lin K.P., and Xiao W. Thermal analysis of a direct gain room with shape-stabilized PCM plates. Renew Energy 33 (2008) 1228-1236
    • (2008) Renew Energy , vol.33 , pp. 1228-1236
    • Zhou, G.B.1    Zhang, Y.P.2    Lin, K.P.3    Xiao, W.4
  • 31
    • 84881358939 scopus 로고    scopus 로고
    • ASHRAE. ASHRAE handbook - Fundamentals, Chapter 3: Heat transfer. Atlanta: ASHRAE; 2001.
    • ASHRAE. ASHRAE handbook - Fundamentals, Chapter 3: Heat transfer. Atlanta: ASHRAE; 2001.
  • 32
    • 85136102120 scopus 로고
    • Radiation analysis by network method
    • Oppenheim A.K. Radiation analysis by network method. Trans ASME 65 (1956) 725-735
    • (1956) Trans ASME , vol.65 , pp. 725-735
    • Oppenheim, A.K.1
  • 34
    • 0026226247 scopus 로고
    • An analysis of office equipment load factors
    • Wilkins C.K., Kosonen R., and Laine T. An analysis of office equipment load factors. ASHRAE J 33 (1991) 38-44
    • (1991) ASHRAE J , vol.33 , pp. 38-44
    • Wilkins, C.K.1    Kosonen, R.2    Laine, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.