메뉴 건너뛰기




Volumn 33, Issue , 2006, Pages 877-880

Characterization of ventricular torsion in healthy subjects using gabor filters and a variational framework

Author keywords

[No Author keywords available]

Indexed keywords

CARDIOLOGY; CHLORINE COMPOUNDS; DEFORMATION; FILTER BANKS; IMAGE ENHANCEMENT; IMAGING TECHNIQUES; MAGNETIC RESONANCE IMAGING; MAPS; OPTICAL FLOWS; TORSIONAL STRESS; WAVE FILTERS;

EID: 50149113899     PISSN: 02766574     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (14)
  • 1
    • 0024318208 scopus 로고
    • Mr imaging of motion with spatial modulation of magnetization
    • Axel L, Dougherty L. Mr imaging of motion with spatial modulation of magnetization. Radiology 1989;171:841-845.
    • (1989) Radiology , vol.171 , pp. 841-845
    • Axel, L.1    Dougherty, L.2
  • 2
    • 0028397086 scopus 로고
    • Tag and contour detection in tagged mr imagesof the left ventricle
    • Guttman M, Prince J, McVeigh E. Tag and contour detection in tagged mr imagesof the left ventricle. IEEE Trans Med Im 1989;13:74-88.
    • (1989) IEEE Trans Med Im , vol.13 , pp. 74-88
    • Guttman, M.1    Prince, J.2    McVeigh, E.3
  • 3
    • 50149106432 scopus 로고
    • A map framework for tag line detection in spamm data using markov random fields on the b-spline solid
    • Chen Y, Amini A. A map framework for tag line detection in spamm data using markov random fields on the b-spline solid. Radiology 1989;171:841-845.
    • (1989) Radiology , vol.171 , pp. 841-845
    • Chen, Y.1    Amini, A.2
  • 4
    • 0028396887 scopus 로고
    • Optimal brightness functions for optical flow estimation of deformable motion
    • Denney T, Prince J. Optimal brightness functions for optical flow estimation of deformable motion. IEEE Trans Imag Proc 1994;3:178-191.
    • (1994) IEEE Trans Imag Proc , vol.3 , pp. 178-191
    • Denney, T.1    Prince, J.2
  • 9
    • 3042604331 scopus 로고    scopus 로고
    • Rapid 3d lv strain reconstruction from tagged cardiac mr images
    • Deng X, Denney T. Rapid 3d lv strain reconstruction from tagged cardiac mr images. In Proceedings of ISMRM, volume 11. 2003; .
    • (2003) Proceedings of ISMRM , vol.11
    • Deng, X.1    Denney, T.2
  • 11
    • 3042597716 scopus 로고    scopus 로고
    • Extracting tissue deformation using gabor filter banks
    • Montillo A, Metaxas D, Axel L. Extracting tissue deformation using gabor filter banks. In Proceedings of SPIE, volume 5369. 2004; 1-9.
    • (2004) In Proceedings of SPIE , vol.5369 , pp. 1-9
    • Montillo, A.1    Metaxas, D.2    Axel, L.3
  • 14
    • 0034076490 scopus 로고    scopus 로고
    • Delineation of normal human left ventricular twist throughout systole by tagged cine magnetic resonance imaging
    • Lorenz C, Pastorek J, Bundy J. Delineation of normal human left ventricular twist throughout systole by tagged cine magnetic resonance imaging. J Cardiovasc Magn Reson 2000;2(2):97-108.
    • (2000) J Cardiovasc Magn Reson , vol.2 , Issue.2 , pp. 97-108
    • Lorenz, C.1    Pastorek, J.2    Bundy, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.