메뉴 건너뛰기




Volumn 49, Issue 7, 2008, Pages 755-760

High-resolution computed tomography with 16-row MDCT: A comparison regarding visibility and motion artifacts of dose-modulated thin slices and "step and shoot" images

Author keywords

CT technique; High resolution CT; Lung structures; Thorax

Indexed keywords

DIAGNOSTIC RADIOGRAPHY; HEALTH; IMAGE ENHANCEMENT; IMAGE QUALITY; IMAGING TECHNIQUES; LAWS AND LEGISLATION; MEDICAL IMAGING; MERGERS AND ACQUISITIONS; MODULATION; OPTICAL PROPERTIES; SIGNAL RECONSTRUCTION; THERMOGRAPHY (TEMPERATURE MEASUREMENT); TOMOGRAPHY; VISIBILITY;

EID: 50149096626     PISSN: 02841851     EISSN: 16000455     Source Type: Journal    
DOI: 10.1080/02841850802078128     Document Type: Article
Times cited : (12)

References (15)
  • 2
    • 0038037974 scopus 로고    scopus 로고
    • Radiation exposure at chest CT: A statement of the Fleischner Society
    • Mayo JR, Aldrich J, Muller NL. Radiation exposure at chest CT: a statement of the Fleischner Society. Radiology 2003;228:15-21.
    • (2003) Radiology , vol.228 , pp. 15-21
    • Mayo, J.R.1    Aldrich, J.2    Muller, N.L.3
  • 3
    • 0025943263 scopus 로고
    • Assessment of diffuse infiltrative lung disease: Comparison of conventional CT and high-resolution CT
    • Remy-Jardin M, Remy J, Deffontaines C, Duhamel A. Assessment of diffuse infiltrative lung disease: comparison of conventional CT and high-resolution CT. Radiology 1991;181:157-62.
    • (1991) Radiology , vol.181 , pp. 157-162
    • Remy-Jardin, M.1    Remy, J.2    Deffontaines, C.3    Duhamel, A.4
  • 5
    • 50149101250 scopus 로고    scopus 로고
    • GE Healthcare Light Speed. Learning and reference guide 2369749-142
    • General Electric Company
    • General Electric Company (2004). GE Healthcare Light Speed. Learning and reference guide 2369749-142, revision 4.
    • (2004) revision , vol.4
  • 7
    • 50149104106 scopus 로고    scopus 로고
    • NEMA. Digital Imaging and Communications in Medicine (DICOM) part 14: grayscale display and standard function. Rosslyn, VA: National Electrical Manufacturers Association; Tech. Rep.; 2004:PS 3.14.
    • NEMA. Digital Imaging and Communications in Medicine (DICOM) part 14: grayscale display and standard function. Rosslyn, VA: National Electrical Manufacturers Association; Tech. Rep.; 2004:PS 3.14.
  • 8
    • 33846709498 scopus 로고    scopus 로고
    • European guidelines on quality criteria for computed tomography
    • Commission of the European Communities, 16262 EN. Luxembourg: Office for Official Publications of the European Communities;
    • Commission of the European Communities. European guidelines on quality criteria for computed tomography. Report EUR 16262 EN. Luxembourg: Office for Official Publications of the European Communities; 1996.
    • (1996) Report EUR
  • 10
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley JA, McNeill BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982;143:29-36.
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeill, B.J.2
  • 11
    • 34347238949 scopus 로고    scopus 로고
    • Visual grading characteristics (VGC) analysis: A non-parametric rank-invariant statistical method for image quality evaluation
    • Båth M, Månsson LG. Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation. Br J Radiol 2007;80:169-76.
    • (2007) Br J Radiol , vol.80 , pp. 169-176
    • Båth, M.1    Månsson, L.G.2
  • 12
    • 28144437469 scopus 로고    scopus 로고
    • Multi-detector row CT and postprocessing techniques in the assessment of diffuse lung disease
    • Beigelman-Aubry C, Hill C, Guibal A, Savatovsky J, Grenier PA. Multi-detector row CT and postprocessing techniques in the assessment of diffuse lung disease. Radiographics 2005;25:1639-52.
    • (2005) Radiographics , vol.25 , pp. 1639-1652
    • Beigelman-Aubry, C.1    Hill, C.2    Guibal, A.3    Savatovsky, J.4    Grenier, P.A.5
  • 13
    • 1442305589 scopus 로고    scopus 로고
    • High-resolution CT using MDCT: Comparison of degree of motion artifact between volumetric and axial methods
    • Kelly DM, Hasegawa I, Borders R, Hatabu H, Boiselle PM. High-resolution CT using MDCT: comparison of degree of motion artifact between volumetric and axial methods. Am J Roentgenol 2004;182:757-9.
    • (2004) Am J Roentgenol , vol.182 , pp. 757-759
    • Kelly, D.M.1    Hasegawa, I.2    Borders, R.3    Hatabu, H.4    Boiselle, P.M.5
  • 14
    • 0034989937 scopus 로고    scopus 로고
    • Multislice helical CT of focal and diffuse lung disease: Comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan
    • Schoepf UJ, Bruening RD, Hong C, Eibel R, Aydemir S, Crispin A, et al. Multislice helical CT of focal and diffuse lung disease: comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan. Am J Roentgenol 2001;177:179-84.
    • (2001) Am J Roentgenol , vol.177 , pp. 179-184
    • Schoepf, U.J.1    Bruening, R.D.2    Hong, C.3    Eibel, R.4    Aydemir, S.5    Crispin, A.6
  • 15
    • 27744452595 scopus 로고    scopus 로고
    • Image quality from high-resolution CT of the lung: Comparison of axial scans and of sections reconstructed from volumetric data acquired using MDCT
    • Studler U, Gluecker T, Bongartz G, Roth J, Steinbrich W. Image quality from high-resolution CT of the lung: comparison of axial scans and of sections reconstructed from volumetric data acquired using MDCT. Am J Roentgenol 2005;185:602-7.
    • (2005) Am J Roentgenol , vol.185 , pp. 602-607
    • Studler, U.1    Gluecker, T.2    Bongartz, G.3    Roth, J.4    Steinbrich, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.