메뉴 건너뛰기




Volumn 86, Issue 4, 2008, Pages 1106-1112

Mechanical and chemical characteristics of an autologous glue

Author keywords

Autologous glue; Mechanical characteristics; Surgery

Indexed keywords

ALDEHYDES; COMMUNICATION SATELLITES; CONCENTRATION (PROCESS); CROSSLINKING; ELASTICITY; GAS METAL ARC WELDING; GLUES; GLUING; MIXING; PLASMA (HUMAN); PLASMAS; STRENGTH OF MATERIALS; TENSILE STRENGTH; TENSILE TESTING;

EID: 50149084907     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.31705     Document Type: Article
Times cited : (10)

References (22)
  • 1
    • 0034810587 scopus 로고    scopus 로고
    • Tissue sealing
    • Morikawa T. Tissue sealing. Am J Surg 2001;182(2 Suppl):29S-35S.
    • (2001) Am J Surg , vol.182 , Issue.2 SUPPL.
    • Morikawa, T.1
  • 2
    • 0345688633 scopus 로고    scopus 로고
    • BioGlue: Albumin/glutaraldehyde sealant in cardiac surgery
    • Chao HH, Torchiana DF. BioGlue: Albumin/glutaraldehyde sealant in cardiac surgery. J Card Surg 2003;18:500-503.
    • (2003) J Card Surg , vol.18 , pp. 500-503
    • Chao, H.H.1    Torchiana, D.F.2
  • 3
    • 33646488990 scopus 로고    scopus 로고
    • Antigenic responses to bovine thrombin exposure during surgery: A prospective study of 309 patients
    • Winterbottom N, Kuo J, Nguyen K, Reich C, Trent K, Rondinone J, Shargill N. Antigenic responses to bovine thrombin exposure during surgery: A prospective study of 309 patients. J Appl Res 2002;2:1-12.
    • (2002) J Appl Res , vol.2 , pp. 1-12
    • Winterbottom, N.1    Kuo, J.2    Nguyen, K.3    Reich, C.4    Trent, K.5    Rondinone, J.6    Shargill, N.7
  • 4
    • 0032799189 scopus 로고    scopus 로고
    • Aprotinin in fibrin tissue adhesives induces specific antibody response and increases antibody response of high-dose intravenous application
    • Scheule AM, Beierlein W, Wendel HP, Jurmann MJ, Eckstein FS, Ziemer G. Aprotinin in fibrin tissue adhesives induces specific antibody response and increases antibody response of high-dose intravenous application. J Thorac Cardiovasc Surg 1999;118:348-353.
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 348-353
    • Scheule, A.M.1    Beierlein, W.2    Wendel, H.P.3    Jurmann, M.J.4    Eckstein, F.S.5    Ziemer, G.6
  • 5
    • 0034067994 scopus 로고    scopus 로고
    • An immediate, allergic skin reaction to aprotinin after reexposure to fibrin sealant
    • Beierlein W, Scheule AM, Antoniadis G, Braun C, Schosser R. An immediate, allergic skin reaction to aprotinin after reexposure to fibrin sealant. Transfusion 2000;40:302-305.
    • (2000) Transfusion , vol.40 , pp. 302-305
    • Beierlein, W.1    Scheule, A.M.2    Antoniadis, G.3    Braun, C.4    Schosser, R.5
  • 6
    • 20444439267 scopus 로고    scopus 로고
    • Biochemical characterization of autologous fibrin sealants produced by CryoSeal and Vivostat in comparison to the homologous fibrin sealant product Tissucol/Tisseel
    • Buchta C, Hedrich HC, Macher M, Hocker P, Redl H. Biochemical characterization of autologous fibrin sealants produced by CryoSeal and Vivostat in comparison to the homologous fibrin sealant product Tissucol/Tisseel. Biomaterials 2005;26:6233-6241.
    • (2005) Biomaterials , vol.26 , pp. 6233-6241
    • Buchta, C.1    Hedrich, H.C.2    Macher, M.3    Hocker, P.4    Redl, H.5
  • 8
    • 33645304291 scopus 로고    scopus 로고
    • Recent clinical and investigational applications of fibrin sealant in selected surgical specialties
    • Albala DM, Lawson JH. Recent clinical and investigational applications of fibrin sealant in selected surgical specialties. J Am Coll Surg 2006;202:685-697.
    • (2006) J Am Coll Surg , vol.202 , pp. 685-697
    • Albala, D.M.1    Lawson, J.H.2
  • 9
    • 0001472579 scopus 로고
    • Necrosis of the arterial wall following application of methyl 2-cyanoacrilate
    • Weisberg D, Goetz RH. Necrosis of the arterial wall following application of methyl 2-cyanoacrilate. Surg Gynecol Obstet 1964;119:1248-1252.
    • (1964) Surg Gynecol Obstet , vol.119 , pp. 1248-1252
    • Weisberg, D.1    Goetz, R.H.2
  • 10
    • 0034122915 scopus 로고    scopus 로고
    • Microvascular anastomosis using 2-octyl cyanoacrylate in the rat femoral artery
    • Hall WW, Wrye SW, Banducci DR, Ehrlich P. Microvascular anastomosis using 2-octyl cyanoacrylate in the rat femoral artery. Ann Plast Surg 2000;44:508-511.
    • (2000) Ann Plast Surg , vol.44 , pp. 508-511
    • Hall, W.W.1    Wrye, S.W.2    Banducci, D.R.3    Ehrlich, P.4
  • 12
    • 0035909969 scopus 로고    scopus 로고
    • Genetic variation in coagulation and fibrinolytic proteins and their relation with acute myocardial infarction: A systematic review
    • Boekholdt SM, Bijsterveld NR, Moons AH, Levi M, Buller HR, Peters RJ. Genetic variation in coagulation and fibrinolytic proteins and their relation with acute myocardial infarction: A systematic review. Circulation 2001;104:3063-3068.
    • (2001) Circulation , vol.104 , pp. 3063-3068
    • Boekholdt, S.M.1    Bijsterveld, N.R.2    Moons, A.H.3    Levi, M.4    Buller, H.R.5    Peters, R.J.6
  • 13
    • 24644479049 scopus 로고    scopus 로고
    • Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissection
    • Bernabeu E, Castellá M, Barriuso C, Mulet J. Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissection. Interact CardioVasc Thorac Surg 2005;4:329-331.
    • (2005) Interact CardioVasc Thorac Surg , vol.4 , pp. 329-331
    • Bernabeu, E.1    Castellá, M.2    Barriuso, C.3    Mulet, J.4
  • 14
    • 20544468247 scopus 로고    scopus 로고
    • The threat of adhesive embolization: BioGlue leaks through needle holes in aortic tissue and prosthetic grafts
    • discussion 110-111
    • LeMaire SA, Carter SA, Won T, Wang X, Conklin LD, Coselli JS. The threat of adhesive embolization: BioGlue leaks through needle holes in aortic tissue and prosthetic grafts. Ann Thorac Surg 2005;80:106-110; discussion 110-111.
    • (2005) Ann Thorac Surg , vol.80 , pp. 106-110
    • LeMaire, S.A.1    Carter, S.A.2    Won, T.3    Wang, X.4    Conklin, L.D.5    Coselli, J.S.6
  • 15
    • 8444230519 scopus 로고    scopus 로고
    • Glutaraldehyde: Behavior in aqueous solution, reaction with proteins, and application to enzyme crosslinking
    • Migneault I, Dartiguenave C, Bertrand MJ, Waldron KC. Glutaraldehyde: Behavior in aqueous solution, reaction with proteins, and application to enzyme crosslinking. Biotechniques 2004;37:790-796,798-802.
    • (2004) Biotechniques , vol.37 , Issue.790-796 , pp. 798-802
    • Migneault, I.1    Dartiguenave, C.2    Bertrand, M.J.3    Waldron, K.C.4
  • 21
    • 15944399398 scopus 로고    scopus 로고
    • Genetic toxicity and carcinogenicity studies of glutaraldehyde - A review
    • Zeiger E, Gollapudi B, Spencer P. Genetic toxicity and carcinogenicity studies of glutaraldehyde - A review. Mutat Res 2005;589:136-151.
    • (2005) Mutat Res , vol.589 , pp. 136-151
    • Zeiger, E.1    Gollapudi, B.2    Spencer, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.