메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1726-1731

Modeling and simulation of Dynamic Voltage Restorer (DVR) based on hysteresis voltage control

Author keywords

Dynamic voltage restorer (DVR); Hysteresis voltage control; Simlink' SimPowerSystem toolbox

Indexed keywords

DISCRETE FOURIER TRANSFORMS; ELASTICITY; ELECTRIC CONTROL EQUIPMENT; ELECTRIC POTENTIAL; ELECTRONICS INDUSTRY; FOURIER TRANSFORMS; HYSTERESIS; INDUSTRIAL ELECTRONICS; VIDEODISKS; VOLTAGE CONTROL; VOLTAGE REGULATORS; VOLTAGE STABILIZING CIRCUITS;

EID: 50049127879     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IECON.2007.4459890     Document Type: Conference Paper
Times cited : (57)

References (10)
  • 1
    • 0032649570 scopus 로고    scopus 로고
    • Experience With An Inverter-Based Dynamic Voltage Restorer
    • July
    • N. H. Woodley, L. Morgan. , and A. Sundaram, "Experience With An Inverter-Based Dynamic Voltage Restorer," IEEE Trans. Power Delivery, vol. 14, No. 3 pp. 549-557, July 1999.
    • (1999) IEEE Trans. Power Delivery , vol.14 , Issue.3 , pp. 549-557
    • Woodley, N.H.1    Morgan, L.2    Sundaram, A.3
  • 3
    • 0035151806 scopus 로고    scopus 로고
    • Comparison system topologies for dynamic voltage restorer
    • J.G Nielsen and F. Balaabjerg," Comparison system topologies for dynamic voltage restorer," in Proc. IEEE/IAS01 Conf., 2001, pp. 2397-2403.
    • (2001) Proc. IEEE/IAS01 Conf , pp. 2397-2403
    • Nielsen, J.G.1    Balaabjerg, F.2
  • 4
    • 0035063843 scopus 로고    scopus 로고
    • th Appl. Power Electron. Conf. Expo., Anaheim, C.A, 2001, pp. 1267-1273.
    • th Appl. Power Electron. Conf. Expo., Anaheim, C.A, 2001, pp. 1267-1273.
  • 6
    • 0347337893 scopus 로고    scopus 로고
    • Design of a Capacitor-Supported Dynamic Voltage Restorer (DVR) for Unbalanced and Distorted Loads
    • January
    • Arindam Ghosh, Amit Kumar Jindal and Avinash Joshi, "Design of a Capacitor-Supported Dynamic Voltage Restorer (DVR) for Unbalanced and Distorted Loads," IEEE Trans. Power Delivery, vol. 19, No.l pp. 405-413, January 2004.
    • (2004) IEEE Trans. Power Delivery , vol.19 , Issue.L , pp. 405-413
    • Ghosh, A.1    Kumar Jindal, A.2    Joshi, A.3
  • 8
    • 26844523410 scopus 로고    scopus 로고
    • Statistical Analysis of Voltage DIP's and Interruption-Final results from the EPRI distribution system power quality monitoring survey
    • ch.2
    • D. D Solin, T. E. Grebe, M. F. Granaghan and A. Sundarm," Statistical Analysis of Voltage DIP's and Interruption-Final results from the EPRI distribution system power quality monitoring survey," in Proc. CIRED'99,ch.2 1999.
    • (1999) Proc. CIRED'99
    • Solin, D.D.1    Grebe, T.E.2    Granaghan, M.F.3    Sundarm, A.4
  • 9
    • 1842581905 scopus 로고    scopus 로고
    • Voltage Sag Detection Technique for a Dynamic Voltage Restorer
    • January/February
    • Chris Fitzer, Mike Barns and Peter Green, "Voltage Sag Detection Technique for a Dynamic Voltage Restorer," IEEE Trans. Power Delivery, vol. 40, No.l pp. 203-212, January/February 2004.
    • (2004) IEEE Trans. Power Delivery , vol.40 , Issue.L , pp. 203-212
    • Fitzer, C.1    Barns, M.2    Green, P.3
  • 10
    • 50049112556 scopus 로고    scopus 로고
    • IEEE recommended practices and requirements for harmonic control in electrical power systems
    • IEEE recommended practices and requirements for harmonic control in electrical power systems, IEEE Standard 519-1992, 1002.
    • IEEE Standard , vol.519 , pp. 1002