메뉴 건너뛰기




Volumn 34, Issue 9, 2008, Pages 1513-1527

Evaluation of a Novel Solid-State Method for Determining the Acoustic Power Generated by Physiotherapy Ultrasound Transducers

Author keywords

Physiotherapy transducers; Polyvinylidene fluoride; Pyroelectric method; Thermal technique; Ultrasonic power measurement

Indexed keywords

ACOUSTIC POWERS; BACKING MATERIALS; PHYSIOTHERAPY TRANSDUCERS; PIEZOELECTRIC POLYMERS; POLYVINYLIDENE FLUORIDE; POWER LEVELING; POWER SOURCING; PYROELECTRIC METHOD; RAPID HEATING; RATE OF CHANGE; SENSOR PERFORMANCES; SOLID-STATE METHODS; SYSTEMATIC EVALUATION; THERMAL TECHNIQUE; THIN MEMBRANES; TRANSDUCER EXCITATION; ULTRASONIC POWER MEASUREMENT; ULTRASOUND TRANSDUCERS;

EID: 49849093162     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2008.02.003     Document Type: Article
Times cited : (12)

References (24)
  • 1
    • 0021522267 scopus 로고
    • The influence of membrane reflections on ultrasonic power measurements
    • Beissner K. The influence of membrane reflections on ultrasonic power measurements. J Acoust Soc Am 50 (1984) 1505-1510
    • (1984) J Acoust Soc Am , vol.50 , pp. 1505-1510
    • Beissner, K.1
  • 2
    • 0011285023 scopus 로고
    • Radiation force and force balances
    • Ziskin M.C., and Lewin P.A. (Eds), CRC Press, Boca Raton, FL
    • Beissner K. Radiation force and force balances. In: Ziskin M.C., and Lewin P.A. (Eds). Ultrasonic Exposimetry (1993), CRC Press, Boca Raton, FL 127-142
    • (1993) Ultrasonic Exposimetry , pp. 127-142
    • Beissner, K.1
  • 3
    • 0011285023 scopus 로고
    • Thermal techniques
    • Ziskin M.C., and Lewin P.A. (Eds), CRC Press, Boca Raton, FL
    • Beissner K. Thermal techniques. In: Ziskin M.C., and Lewin P.A. (Eds). Ultrasonic Exposimetry (1993), CRC Press, Boca Raton, FL 163-168
    • (1993) Ultrasonic Exposimetry , pp. 163-168
    • Beissner, K.1
  • 4
    • 0001814584 scopus 로고
    • Ultrasonic power balances
    • Preston R.C. (Ed), Springer-Verlag, London
    • Davidson F. Ultrasonic power balances. In: Preston R.C. (Ed). Output Measurements for Medical Ultrasound (1991), Springer-Verlag, London 75-90
    • (1991) Output Measurements for Medical Ultrasound , pp. 75-90
    • Davidson, F.1
  • 5
    • 0030164985 scopus 로고    scopus 로고
    • The thermoacoustic effect and its use in ultrasonic power determination
    • Fay B., and Rinker M. The thermoacoustic effect and its use in ultrasonic power determination. Ultrasonics 34 (1996) 563-566
    • (1996) Ultrasonics , vol.34 , pp. 563-566
    • Fay, B.1    Rinker, M.2
  • 6
    • 30244463882 scopus 로고
    • Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes
    • Fry W.J., and Fry W.B. Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes. J Acoust Soc Am 26 (1954) 294-317
    • (1954) J Acoust Soc Am , vol.26 , pp. 294-317
    • Fry, W.J.1    Fry, W.B.2
  • 8
    • 33751333444 scopus 로고    scopus 로고
    • Therapeutic applications of ultrasound
    • ter Haar G.R. Therapeutic applications of ultrasound. Progr Biophys Mol Biol 93 1-3 (2007) 111-129
    • (2007) Progr Biophys Mol Biol , vol.93 , Issue.1-3 , pp. 111-129
    • ter Haar, G.R.1
  • 9
    • 0034318050 scopus 로고    scopus 로고
    • The impact of piezoelectric pvdf on medical ultrasound exposure measurements, standards and regulations
    • Harris G.R., Preston R.C., and DeReggi A.S. The impact of piezoelectric pvdf on medical ultrasound exposure measurements, standards and regulations. IEEE Trans Ultrason Ferroelectr Freq Control 47 6 (2000) 1321-1335
    • (2000) IEEE Trans Ultrason Ferroelectr Freq Control , vol.47 , Issue.6 , pp. 1321-1335
    • Harris, G.R.1    Preston, R.C.2    DeReggi, A.S.3
  • 11
    • 49849086410 scopus 로고    scopus 로고
    • Hekkenberg RT, Beissner, K, Zeqiri, B. Therapy-level ultrasonic power measurement. Final Technical Report SMT4-T96-2139, European Commission, BCR Information, report EUR 18828 ISSN 2000.
    • Hekkenberg RT, Beissner, K, Zeqiri, B. Therapy-level ultrasonic power measurement. Final Technical Report SMT4-T96-2139, European Commission, BCR Information, report EUR 18828 ISSN 2000.
  • 13
    • 0028212543 scopus 로고
    • Development of standard measurement methods for the essential properties of ultrasound therapy equipment
    • Hekkenberg R.T., Reibold R., and Zeqiri B. Development of standard measurement methods for the essential properties of ultrasound therapy equipment. Ultrasound Med Biol 20 1 (1994) 83-94
    • (1994) Ultrasound Med Biol , vol.20 , Issue.1 , pp. 83-94
    • Hekkenberg, R.T.1    Reibold, R.2    Zeqiri, B.3
  • 19
    • 36149063885 scopus 로고
    • The absorption of ultrasonic waves in liquids and its relation to molecular constitution
    • Pinkerton J.M.M. The absorption of ultrasonic waves in liquids and its relation to molecular constitution. Proc Phys Soc 62 (1949) 129-141
    • (1949) Proc Phys Soc , vol.62 , pp. 129-141
    • Pinkerton, J.M.M.1
  • 20
    • 0028339558 scopus 로고
    • The performance of ultrasound physiotherapy machines in the Lothian Region, Scotland
    • Pye S.D., and Milford C. The performance of ultrasound physiotherapy machines in the Lothian Region, Scotland. Ultrasound Med Biol 20 (1992) 347-359
    • (1992) Ultrasound Med Biol , vol.20 , pp. 347-359
    • Pye, S.D.1    Milford, C.2
  • 22
    • 49849097773 scopus 로고    scopus 로고
    • Safety Action Notice SAN(SC) 06/44, Scottish Healthcare Supplies, Edinburgh. September 2006.
    • Safety Action Notice SAN(SC) 06/44, Scottish Healthcare Supplies, Edinburgh. September 2006.
  • 23
    • 0034117818 scopus 로고    scopus 로고
    • A new anechoic material for medical ultrasonic applications
    • Zeqiri B., and Bickley C.J. A new anechoic material for medical ultrasonic applications. Ultrasound Med Biol 26 3 (2000) 481-485
    • (2000) Ultrasound Med Biol , vol.26 , Issue.3 , pp. 481-485
    • Zeqiri, B.1    Bickley, C.J.2
  • 24
    • 37049024062 scopus 로고    scopus 로고
    • A novel pyroelectric method of determining ultrasonic transducer output power: device concept, modelling and preliminary studies
    • Zeqiri B., Gelat P.N., Barrie J., and Bickley C.J. A novel pyroelectric method of determining ultrasonic transducer output power: device concept, modelling and preliminary studies. IEEE Trans Ultrason Ferroelectr Freq Control 54 11 (2007) 2318-2330
    • (2007) IEEE Trans Ultrason Ferroelectr Freq Control , vol.54 , Issue.11 , pp. 2318-2330
    • Zeqiri, B.1    Gelat, P.N.2    Barrie, J.3    Bickley, C.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.