Volumn 34, Issue 9, 2008, Pages 1718-1723

Comparison of lung tissue concentrations of nebulized ceftazidime in ventilated piglets: Ultrasonic versus vibrating plate nebulizers

Author keywords

Lung tissue concentration; Nebulization of antibiotics; Nebulizer; Ultrasonic; Vibrating plate

Indexed keywords

CEFTAZIDIME;

EID: 49749140066     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00134-008-1126-4     Document Type: Article
Times cited : (37)

References (20)
  • 1
    • 0028040181 scopus 로고
    • Aerosol deposition in mechanically ventilated patients. Optimizing nebulizer delivery
    • TG O'Riordan LB Palmer GC Smaldone 1994 Aerosol deposition in mechanically ventilated patients. Optimizing nebulizer delivery Am J Respir Crit Care Med 149 214 219
    • (1994) Am J Respir Crit Care Med , vol.149 , pp. 214-219
    • O'Riordan, T.G.1    Palmer, L.B.2    Smaldone, G.C.3
  • 2
    • 33846309189 scopus 로고    scopus 로고
    • Effective inhaled drug administration to mechanically ventilated patients
    • R Dhand E Mercier 2007 Effective inhaled drug administration to mechanically ventilated patients Expert Opin Drug Deliv 4 47 61
    • (2007) Expert Opin Drug Deliv , vol.4 , pp. 47-61
    • Dhand, R.1    Mercier, E.2
  • 8
    • 17844393121 scopus 로고    scopus 로고
    • Intravenous versus nebulized ceftazidime in ventilated piglets with and without experimental bronchopneumonia: Comparative effects of helium and nitrogen
    • M Tonnellier F Ferrari I Goldstein A Sartorius CH Marquette JJ Rouby 2005 Intravenous versus nebulized ceftazidime in ventilated piglets with and without experimental bronchopneumonia: comparative effects of helium and nitrogen Anesthesiology 102 995 1000
    • (2005) Anesthesiology , vol.102 , pp. 995-1000
    • Tonnellier, M.1    Ferrari, F.2    Goldstein, I.3    Sartorius, A.4    Marquette, C.H.5    Rouby, J.J.6
  • 9
    • 18444401720 scopus 로고    scopus 로고
    • Influence of lung aeration on pulmonary concentrations of nebulized and intravenous amikacin in ventilated piglets with severe bronchopneumonia
    • M Elman I Goldstein CH Marquette F Wallet G Lenaour JJ Rouby 2002 Influence of lung aeration on pulmonary concentrations of nebulized and intravenous amikacin in ventilated piglets with severe bronchopneumonia Anesthesiology 97 199 206
    • (2002) Anesthesiology , vol.97 , pp. 199-206
    • Elman, M.1    Goldstein, I.2    Marquette, C.H.3    Wallet, F.4    Lenaour, G.5    Rouby, J.J.6
  • 14
    • 33745615425 scopus 로고    scopus 로고
    • Factors influencing the in vitro deposition of tobramycin aerosol: A comparison of an ultrasonic nebulizer and a high-frequency vibrating mesh nebulizer
    • KM Pedersen VN Handlos L Heslet HG Kristensen 2006 Factors influencing the in vitro deposition of tobramycin aerosol: a comparison of an ultrasonic nebulizer and a high-frequency vibrating mesh nebulizer J Aerosol Med 19 175 183
    • (2006) J Aerosol Med , vol.19 , pp. 175-183
    • Pedersen, K.M.1    Handlos, V.N.2    Heslet, L.3    Kristensen, H.G.4
  • 15
    • 0030936482 scopus 로고    scopus 로고
    • Effect of nebulizer configuration on delivery of aerosolized tobramycin
    • TG O'Riordan JC Amram 1997 Effect of nebulizer configuration on delivery of aerosolized tobramycin J Aerosol Med 10 13 23
    • (1997) J Aerosol Med , vol.10 , pp. 13-23
    • O'Riordan, T.G.1    Amram, J.C.2
  • 16
    • 0032900977 scopus 로고    scopus 로고
    • Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors
    • JB Fink R Dhand J Grychowski PJ Fahey MJ Tobin 1999 Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors Am J Respir Crit Care Med 159 63 68
    • (1999) Am J Respir Crit Care Med , vol.159 , pp. 63-68
    • Fink, J.B.1    Dhand, R.2    Grychowski, J.3    Fahey, P.J.4    Tobin, M.J.5
  • 17
    • 24144457260 scopus 로고    scopus 로고
    • Effects of filtering and delays on the estimates of a nonlinear respiratory mechanics model
    • FC Jandre AR Carvalho AV Pino A Giannella-Neto 2005 Effects of filtering and delays on the estimates of a nonlinear respiratory mechanics model Respir Physiol Neurobiol 148 309 314
    • (2005) Respir Physiol Neurobiol , vol.148 , pp. 309-314
    • Jandre, F.C.1    Carvalho, A.R.2    Pino, A.V.3    Giannella-Neto, A.4
  • 18
    • 0035138503 scopus 로고    scopus 로고
    • Improvement in aerosol delivery with helium-oxygen mixtures during mechanical ventilation
    • ML Goode JB Fink R Dhand MJ Tobin 2001 Improvement in aerosol delivery with helium-oxygen mixtures during mechanical ventilation Am J Respir Crit Care Med 163 109 114
    • (2001) Am J Respir Crit Care Med , vol.163 , pp. 109-114
    • Goode, M.L.1    Fink, J.B.2    Dhand, R.3    Tobin, M.J.4
  • 19
    • 0036885621 scopus 로고    scopus 로고
    • Nebulizers that use a vibrating mesh or plate with multiple apertures to generate aerosol
    • discussion 1416-1408
    • R Dhand 2002 Nebulizers that use a vibrating mesh or plate with multiple apertures to generate aerosol Respir Care 47 1406 1416 discussion 1416-1408
    • (2002) Respir Care , vol.47 , pp. 1406-1416
    • Dhand, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.