메뉴 건너뛰기




Volumn 19, Issue 9, 2008, Pages 1361-1365

Entrance Surface Dose during Three-dimensional Imaging with a Flat-panel Detector Angiography System

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOGRAPHY; ARTICLE; BODY SURFACE; DOSIMETRY; FLAT PANEL DETECTOR ANGIOGRAPHY SYSTEM; IMAGING SYSTEM; NONHUMAN; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION SCATTERING; REGRESSION ANALYSIS; STATISTICAL SIGNIFICANCE; THREE DIMENSIONAL IMAGING;

EID: 49749137378     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvir.2008.05.020     Document Type: Article
Times cited : (7)

References (17)
  • 1
    • 16244392355 scopus 로고    scopus 로고
    • Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector
    • Akpek S., Brunner T., Benndorf G., and Strother C. Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector. Diagn Interv Radiol 11 (2005) 10-13
    • (2005) Diagn Interv Radiol , vol.11 , pp. 10-13
    • Akpek, S.1    Brunner, T.2    Benndorf, G.3    Strother, C.4
  • 2
    • 33748624912 scopus 로고    scopus 로고
    • Evaluation of vascular supply with cone-beam computed tomography during intraarterial chemotherapy for a skull base tumor
    • Ishikura R., Ando K., Nagami Y., et al. Evaluation of vascular supply with cone-beam computed tomography during intraarterial chemotherapy for a skull base tumor. Radiat Med 24 (2006) 384-387
    • (2006) Radiat Med , vol.24 , pp. 384-387
    • Ishikura, R.1    Ando, K.2    Nagami, Y.3
  • 3
    • 33750531430 scopus 로고    scopus 로고
    • Cone-beam CT with flat-panel-detector digital angiography system: early experience in abdominal interventional procedures
    • Hirota S., Nakao N., Yamamoto S., et al. Cone-beam CT with flat-panel-detector digital angiography system: early experience in abdominal interventional procedures. Cardiovasc Intervent Radiol 29 (2006) 1034-1038
    • (2006) Cardiovasc Intervent Radiol , vol.29 , pp. 1034-1038
    • Hirota, S.1    Nakao, N.2    Yamamoto, S.3
  • 4
    • 12844254281 scopus 로고    scopus 로고
    • Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery
    • Siewerdsen J.H., Moseley D.J., Burch S., et al. Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. Med Phys 32 (2005) 241-254
    • (2005) Med Phys , vol.32 , pp. 241-254
    • Siewerdsen, J.H.1    Moseley, D.J.2    Burch, S.3
  • 5
    • 0028185452 scopus 로고
    • Potential biological effects following high x-ray dose interventional procedures
    • Wagner L.K., Eifel P.J., and Geise R.A. Potential biological effects following high x-ray dose interventional procedures. J Vasc Interv Radiol 5 (1994) 71-84
    • (1994) J Vasc Interv Radiol , vol.5 , pp. 71-84
    • Wagner, L.K.1    Eifel, P.J.2    Geise, R.A.3
  • 6
    • 0028883284 scopus 로고
    • Radiation risk and exposure of radiologists and patients during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA)
    • Karppinen J., Parviainen T., Servomaa A., and Komppa T. Radiation risk and exposure of radiologists and patients during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA). Radiat Prot Dosimetry 57 (1995) 481-485
    • (1995) Radiat Prot Dosimetry , vol.57 , pp. 481-485
    • Karppinen, J.1    Parviainen, T.2    Servomaa, A.3    Komppa, T.4
  • 7
    • 0029945748 scopus 로고    scopus 로고
    • Chronic radiodermatitis following cardiac catheterization
    • Lichtenstein D.A., Klapholz L., Vardy D.A., et al. Chronic radiodermatitis following cardiac catheterization. Arch Dermatol 132 (1996) 663-667
    • (1996) Arch Dermatol , vol.132 , pp. 663-667
    • Lichtenstein, D.A.1    Klapholz, L.2    Vardy, D.A.3
  • 8
    • 0003203252 scopus 로고    scopus 로고
    • Radiation induced skin injury after percutaneous transluminal coronary angioplasty: case report
    • Sovik E., Klow N.E., Hellesnes J., and Lykke J. Radiation induced skin injury after percutaneous transluminal coronary angioplasty: case report. Acta Radiol 37 (1996) 305-306
    • (1996) Acta Radiol , vol.37 , pp. 305-306
    • Sovik, E.1    Klow, N.E.2    Hellesnes, J.3    Lykke, J.4
  • 9
    • 0031016963 scopus 로고    scopus 로고
    • Radiodermatitis following cardiac catheterization
    • D'Incan M., and Roger H. Radiodermatitis following cardiac catheterization. Arch Dermatol 133 (1997) 242-243
    • (1997) Arch Dermatol , vol.133 , pp. 242-243
    • D'Incan, M.1    Roger, H.2
  • 10
    • 0030908424 scopus 로고    scopus 로고
    • Acute radiodermatitis after radiofrequency catheter ablation
    • Nahass G.T. Acute radiodermatitis after radiofrequency catheter ablation. J Am Acad Dermatol 36 (1997) 881-884
    • (1997) J Am Acad Dermatol , vol.36 , pp. 881-884
    • Nahass, G.T.1
  • 11
    • 0033194931 scopus 로고    scopus 로고
    • The AAPM/RSNA Physics Tutorial for Residents: typical patient radiation doses in diagnostic radiology
    • Parry R.A., Glaze S.A., and Archer B.R. The AAPM/RSNA Physics Tutorial for Residents: typical patient radiation doses in diagnostic radiology. Radiographics 19 (1999) 1289-1302
    • (1999) Radiographics , vol.19 , pp. 1289-1302
    • Parry, R.A.1    Glaze, S.A.2    Archer, B.R.3
  • 15
    • 32944471741 scopus 로고    scopus 로고
    • Radiation dose to patients and radiologists during transcatheter arterial embolization: comparison of a digital flat-panel system and conventional unit
    • Suzuki S., Furui S., Kobayashi I., et al. Radiation dose to patients and radiologists during transcatheter arterial embolization: comparison of a digital flat-panel system and conventional unit. AJR Am J Roentgenol 185 (2005) 855-859
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 855-859
    • Suzuki, S.1    Furui, S.2    Kobayashi, I.3
  • 17
    • 85008998546 scopus 로고    scopus 로고
    • Avoidance of radiation injuries from medical interventional procedures
    • International Commission on Radiological Protection ICRP Publication 85
    • International Commission on Radiological Protection. Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 30 (2000) 25-43 ICRP Publication 85
    • (2000) Ann ICRP , vol.30 , pp. 25-43


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.