-
1
-
-
0023720657
-
Failure of the metal-backed patellar component after total knee replacement
-
Bayley J.C., Scott R.D., Ewald F.C., et al. Failure of the metal-backed patellar component after total knee replacement. J Bone Joint Surg Am 70 (1988) 668
-
(1988)
J Bone Joint Surg Am
, vol.70
, pp. 668
-
-
Bayley, J.C.1
Scott, R.D.2
Ewald, F.C.3
-
2
-
-
0023792146
-
Patellar component failure in cementless total knee arthroplasty
-
Rosenberg A.G., Andriacchi T.P., Barden R., et al. Patellar component failure in cementless total knee arthroplasty. Clin Orthop Relat Res 236 (1988) 106
-
(1988)
Clin Orthop Relat Res
, vol.236
, pp. 106
-
-
Rosenberg, A.G.1
Andriacchi, T.P.2
Barden, R.3
-
3
-
-
0026058309
-
Polyethylene failure of metal-backed patellar components. 111 AGC total knees followed for 7-22 months
-
Andersen H.N., Ernst C., and Frandsen P.A. Polyethylene failure of metal-backed patellar components. 111 AGC total knees followed for 7-22 months. Acta Orthop Scand 62 (1991) 1
-
(1991)
Acta Orthop Scand
, vol.62
, pp. 1
-
-
Andersen, H.N.1
Ernst, C.2
Frandsen, P.A.3
-
4
-
-
0023769304
-
Fracture/dissociation of the polyethylene in metal-backed patellar components in total knee arthroplasty
-
Lombardi Jr. A.V., Engh G.A., Volz R.G., et al. Fracture/dissociation of the polyethylene in metal-backed patellar components in total knee arthroplasty. J Bone Joint Surg Am 70 (1988) 675
-
(1988)
J Bone Joint Surg Am
, vol.70
, pp. 675
-
-
Lombardi Jr., A.V.1
Engh, G.A.2
Volz, R.G.3
-
6
-
-
0026027764
-
Failure of metal-backed patellar arthroplasty. 47 AGC total knees followed for at least 1 year
-
Baech J., and Kofoed H. Failure of metal-backed patellar arthroplasty. 47 AGC total knees followed for at least 1 year. Acta Orthop Scand 62 (1991) 166
-
(1991)
Acta Orthop Scand
, vol.62
, pp. 166
-
-
Baech, J.1
Kofoed, H.2
-
7
-
-
0030445652
-
Results of total knee arthroplasty with a metal-backed patellar component. A 6-year follow-up study
-
Rader C.P., Lohr J., Wittmann R., et al. Results of total knee arthroplasty with a metal-backed patellar component. A 6-year follow-up study. J Arthroplasty 11 (1996) 923
-
(1996)
J Arthroplasty
, vol.11
, pp. 923
-
-
Rader, C.P.1
Lohr, J.2
Wittmann, R.3
-
8
-
-
0028340594
-
Early failure of metal-backed patellar arthroplasty
-
Levi N., and Kofoed H. Early failure of metal-backed patellar arthroplasty. J Bone Joint Surg Br 76 (1994) 675
-
(1994)
J Bone Joint Surg Br
, vol.76
, pp. 675
-
-
Levi, N.1
Kofoed, H.2
-
9
-
-
0025997555
-
The metal-backed patella. An invitation for failure?
-
Peters J.D., Engh G.A., and Corpe R.S. The metal-backed patella. An invitation for failure?. J Arthroplasty 6 (1991) 221
-
(1991)
J Arthroplasty
, vol.6
, pp. 221
-
-
Peters, J.D.1
Engh, G.A.2
Corpe, R.S.3
-
10
-
-
0032107878
-
Isolated metal-backed patellar component revision following total knee arthroplasty
-
Chan W.H., Yeo S.J., Lee B.P., et al. Isolated metal-backed patellar component revision following total knee arthroplasty. Singapore Med J 39 (1998) 303
-
(1998)
Singapore Med J
, vol.39
, pp. 303
-
-
Chan, W.H.1
Yeo, S.J.2
Lee, B.P.3
-
11
-
-
0035169017
-
Outcome of metal-backed cementless patellar components: the effect of implant design
-
Kraay M.J., Darr O.J., Salata M.J., et al. Outcome of metal-backed cementless patellar components: the effect of implant design. Clin Orthop Relat Res 392 (2001) 239
-
(2001)
Clin Orthop Relat Res
, vol.392
, pp. 239
-
-
Kraay, M.J.1
Darr, O.J.2
Salata, M.J.3
-
12
-
-
4644351651
-
Isolated patellar revisions for failed metal-backed components: 2- to 9-year follow-up
-
Koh J.S., Yeo S.J., Lo N.N., et al. Isolated patellar revisions for failed metal-backed components: 2- to 9-year follow-up. J Arthroplasty 19 (2004) 880
-
(2004)
J Arthroplasty
, vol.19
, pp. 880
-
-
Koh, J.S.1
Yeo, S.J.2
Lo, N.N.3
-
13
-
-
0033783519
-
Revision of failed metal-backed patellar component of Miller/Galante-I total knee prosthesis
-
Kobori M., Kamisato S., Yoshida M., et al. Revision of failed metal-backed patellar component of Miller/Galante-I total knee prosthesis. J Orthop Sci 5 (2000) 436
-
(2000)
J Orthop Sci
, vol.5
, pp. 436
-
-
Kobori, M.1
Kamisato, S.2
Yoshida, M.3
-
14
-
-
0035171805
-
Problems with cementless total knee arthroplasty at 11 years followup
-
Berger R.A., Lyon J.H., Jacobs J.J., et al. Problems with cementless total knee arthroplasty at 11 years followup. Clin Orthop Relat Res 392 (2001) 196
-
(2001)
Clin Orthop Relat Res
, vol.392
, pp. 196
-
-
Berger, R.A.1
Lyon, J.H.2
Jacobs, J.J.3
-
15
-
-
29244454587
-
Isolated revision of failed metal-backed patellar components: outcome with minimum 4-year follow-up
-
Burke W.V., Ammeen D.J., and Engh G.A. Isolated revision of failed metal-backed patellar components: outcome with minimum 4-year follow-up. J Arthroplasty 20 (2005) 998
-
(2005)
J Arthroplasty
, vol.20
, pp. 998
-
-
Burke, W.V.1
Ammeen, D.J.2
Engh, G.A.3
-
16
-
-
0033967283
-
Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints
-
Que L., Topoleski L.D., and Parks N.L. Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints. J Biomed Mater Res 53 (2000) 111
-
(2000)
J Biomed Mater Res
, vol.53
, pp. 111
-
-
Que, L.1
Topoleski, L.D.2
Parks, N.L.3
-
17
-
-
0027411495
-
Isolated patellar component revision of total knee arthroplasty
-
Berry D.J., and Rand J.A. Isolated patellar component revision of total knee arthroplasty. Clin Orthop Relat Res 286 (1993) 110
-
(1993)
Clin Orthop Relat Res
, vol.286
, pp. 110
-
-
Berry, D.J.1
Rand, J.A.2
-
18
-
-
0031225348
-
Midterm results in metal-backed patella revisions for metallosis
-
Arredondo J., Worland R.L., Jessup D.E., et al. Midterm results in metal-backed patella revisions for metallosis. Am J Orthop 26 (1997) 598
-
(1997)
Am J Orthop
, vol.26
, pp. 598
-
-
Arredondo, J.1
Worland, R.L.2
Jessup, D.E.3
-
19
-
-
0037264743
-
Isolated revision of the patellar component in total knee arthroplasty
-
Leopold S.S., Silverton C.D., Barden R.M., et al. Isolated revision of the patellar component in total knee arthroplasty. J Bone Joint Surg Am 85-A (2003) 41
-
(2003)
J Bone Joint Surg Am
, vol.85 -A
, pp. 41
-
-
Leopold, S.S.1
Silverton, C.D.2
Barden, R.M.3
-
20
-
-
0028044658
-
Postoperative alignment of total knee replacement. Its effect on survival
-
Ritter M.A., Faris P.M., Keating E.M., et al. Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299 (1994) 153
-
(1994)
Clin Orthop Relat Res
, vol.299
, pp. 153
-
-
Ritter, M.A.1
Faris, P.M.2
Keating, E.M.3
-
22
-
-
0024950156
-
The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system
-
Ewald F.C. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248 (1989) 9
-
(1989)
Clin Orthop Relat Res
, vol.248
, pp. 9
-
-
Ewald, F.C.1
-
23
-
-
0033761398
-
Serum titanium level for diagnosis of a failed, metal-backed patellar component
-
Leopold S.S., Berger R.A., Patterson L., et al. Serum titanium level for diagnosis of a failed, metal-backed patellar component. J Arthroplasty 15 (2000) 938
-
(2000)
J Arthroplasty
, vol.15
, pp. 938
-
-
Leopold, S.S.1
Berger, R.A.2
Patterson, L.3
-
24
-
-
8644226869
-
Patella resurfacing versus nonresurfacing in total knee arthroplasty: results of a randomized controlled clinical trial at a minimum of 10 years' followup
-
Burnett R.S., Haydon C.M., Rorabeck C.H., et al. Patella resurfacing versus nonresurfacing in total knee arthroplasty: results of a randomized controlled clinical trial at a minimum of 10 years' followup. Clin Orthop Relat Res 428 (2004) 12
-
(2004)
Clin Orthop Relat Res
, vol.428
, pp. 12
-
-
Burnett, R.S.1
Haydon, C.M.2
Rorabeck, C.H.3
-
25
-
-
0041419736
-
Resurfacing versus not resurfacing the patella in total knee arthroplasty: 8- to 10-year results
-
Mayman D., Bourne R.B., Rorabeck C.H., et al. Resurfacing versus not resurfacing the patella in total knee arthroplasty: 8- to 10-year results. J Arthroplasty 18 (2003) 541
-
(2003)
J Arthroplasty
, vol.18
, pp. 541
-
-
Mayman, D.1
Bourne, R.B.2
Rorabeck, C.H.3
-
26
-
-
8644262311
-
Knee simulator wear of polyethylene tibias articulating against explanted rough femoral components
-
Muratoglu O.K., Burroughs B.R., Bragdon C.R., et al. Knee simulator wear of polyethylene tibias articulating against explanted rough femoral components. Clin Orthop Relat Res 428 (2004) 108
-
(2004)
Clin Orthop Relat Res
, vol.428
, pp. 108
-
-
Muratoglu, O.K.1
Burroughs, B.R.2
Bragdon, C.R.3
-
27
-
-
0034106173
-
Effect of fabrication method and resin type on performance of tibial bearings
-
Currier B.H., Currier J.H., Collier J.P., et al. Effect of fabrication method and resin type on performance of tibial bearings. J Biomed Mater Res 53 (2000) 143
-
(2000)
J Biomed Mater Res
, vol.53
, pp. 143
-
-
Currier, B.H.1
Currier, J.H.2
Collier, J.P.3
-
29
-
-
27644575992
-
Revision of the patella with deficient bone using a biconvex component
-
Maheshwer C.B., Mitchell E., Kraay M., et al. Revision of the patella with deficient bone using a biconvex component. Clin Orthop Relat Res 440 (2005) 126
-
(2005)
Clin Orthop Relat Res
, vol.440
, pp. 126
-
-
Maheshwer, C.B.1
Mitchell, E.2
Kraay, M.3
|