메뉴 건너뛰기




Volumn 134, Issue 1, 2008, Pages 25-30

Solid-state potentiometric SO2 sensor combining NASICON with V2O5-doped TiO2 electrode

Author keywords

NASICON; SO2 gas sensor; Solid electrolyte; V2O5 TiO2

Indexed keywords

ELECTRIC CONDUCTIVITY;

EID: 49549115978     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2008.04.003     Document Type: Article
Times cited : (76)

References (23)
  • 9
    • 0021447275 scopus 로고
    • A new sulphur dioxide sensor using a novel two-phase solid-sulphate electrolyte
    • Worrell W.L., and Liu Q. A new sulphur dioxide sensor using a novel two-phase solid-sulphate electrolyte. J. Electrochem. Soc. 168 (1984) 355-362
    • (1984) J. Electrochem. Soc. , vol.168 , pp. 355-362
    • Worrell, W.L.1    Liu, Q.2
  • 10
    • 0022151585 scopus 로고
    • potentiometric sensor for sulfur oxides using NASICON as a solid electrolyte
    • Maruyama T., Saito Y., Matsumoto Y., and Yano Y. potentiometric sensor for sulfur oxides using NASICON as a solid electrolyte. Solid State Ionics 17 (1985) 281-286
    • (1985) Solid State Ionics , vol.17 , pp. 281-286
    • Maruyama, T.1    Saito, Y.2    Matsumoto, Y.3    Yano, Y.4
  • 12
    • 0033908736 scopus 로고    scopus 로고
    • Development of a NASICON-based amperometric carbon dioxide sensor
    • Yang Y., and Liu C. Development of a NASICON-based amperometric carbon dioxide sensor. Sens. Actuators B 62 (2000) 30-34
    • (2000) Sens. Actuators B , vol.62 , pp. 30-34
    • Yang, Y.1    Liu, C.2
  • 14
    • 0001263091 scopus 로고    scopus 로고
    • 2 sensor using NASICON and perovskite-type oxide electrode
    • 2 sensor using NASICON and perovskite-type oxide electrode. Sens. Actuators B 64 (2000) 102-106
    • (2000) Sens. Actuators B , vol.64 , pp. 102-106
    • Shimizu, Y.1    Yamashita, N.2
  • 15
    • 0029292052 scopus 로고
    • Carbon dioxide sensor using NASICON prepared by the sol-gel method
    • Lee D., Choi S., and Lee K. Carbon dioxide sensor using NASICON prepared by the sol-gel method. Sens. Actuators B 24-25 (1995) 607-609
    • (1995) Sens. Actuators B , vol.24-25 , pp. 607-609
    • Lee, D.1    Choi, S.2    Lee, K.3
  • 19
    • 0346342632 scopus 로고    scopus 로고
    • 2 sensor based on solid-electrolyte NASICON synthesized by sol-gel process
    • 2 sensor based on solid-electrolyte NASICON synthesized by sol-gel process. Mater. Chem. Phys. 83 (2004) 193-198
    • (2004) Mater. Chem. Phys. , vol.83 , pp. 193-198
    • Qiu, F.1    Zhu, Q.2    Yang, X.3    Quan, Y.4    Xu, B.5
  • 20
    • 0242658663 scopus 로고    scopus 로고
    • Preparation and characterization of NASICON with a new sol-gel process
    • Zhang S., Quan B., Zhao Z., Zhao B., He Y., and Chen W. Preparation and characterization of NASICON with a new sol-gel process. Mater. Lett. 58 (2003) 226-229
    • (2003) Mater. Lett. , vol.58 , pp. 226-229
    • Zhang, S.1    Quan, B.2    Zhao, Z.3    Zhao, B.4    He, Y.5    Chen, W.6
  • 21
    • 0000241282 scopus 로고    scopus 로고
    • 2 based on stabilized zirconia and spinel-type oxide electrodes
    • 2 based on stabilized zirconia and spinel-type oxide electrodes. J. Mater. Chem. 7 (1997) 1445-1449
    • (1997) J. Mater. Chem. , vol.7 , pp. 1445-1449
    • Lu, G.1    Miura, N.2    Yamazoe, N.3
  • 22
    • 0030233438 scopus 로고    scopus 로고
    • High-temperature hydrogen sensor based on stabilized zirconia and a metal oxide electrode
    • Lu G., Miura N., and Yamazoe N. High-temperature hydrogen sensor based on stabilized zirconia and a metal oxide electrode. Sens. Actuators B 35-36 (1996) 130-135
    • (1996) Sens. Actuators B , vol.35-36 , pp. 130-135
    • Lu, G.1    Miura, N.2    Yamazoe, N.3
  • 23
    • 0034733350 scopus 로고    scopus 로고
    • x sensor combined with NASICON and Pb-Ru-based pyrochlore-type oxide electrode
    • x sensor combined with NASICON and Pb-Ru-based pyrochlore-type oxide electrode. Sens. Actuators B 65 (2000) 141-143
    • (2000) Sens. Actuators B , vol.65 , pp. 141-143
    • Shimizu, Y.1    Nishi, H.2    Suzuki, H.3    Maeda, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.