메뉴 건너뛰기




Volumn 55, Issue 8, 2008, Pages 1878-1882

High frequency coded imaging system with RF software signal processing

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC WAVES; CODES (STANDARDS); CODES (SYMBOLS); DATA PROCESSING; DIGITAL IMAGE STORAGE; FIELD PROGRAMMABLE GATE ARRAYS (FPGA); IMAGING SYSTEMS; IMAGING TECHNIQUES; OPTOELECTRONIC DEVICES; SIGNAL PROCESSING; SOFTWARE ARCHITECTURE; ULTRASONIC APPLICATIONS; ULTRASONICS;

EID: 49449116989     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2008.871     Document Type: Article
Times cited : (28)

References (17)
  • 1
    • 0031675580 scopus 로고    scopus 로고
    • Pulse elongation and deconvolution filtering for medical ultrasonic imaging
    • B. Haider, P. A. Lewin, and K. E. Thomenius, "Pulse elongation and deconvolution filtering for medical ultrasonic imaging," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 45, no. 1, pp. 98-113, 1998.
    • (1998) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.45 , Issue.1 , pp. 98-113
    • Haider, B.1    Lewin, P.A.2    Thomenius, K.E.3
  • 3
    • 0037972744 scopus 로고    scopus 로고
    • Clinical evaluation of chirp coded excitation in medical ultrasound
    • M. H. Pedersen, T. X. Misaridis, and J. A. Jensen, "Clinical evaluation of chirp coded excitation in medical ultrasound," Ultrasound Med. Biol., vol. 29, no. 6, pp. 895-905, 2003.
    • (2003) Ultrasound Med. Biol , vol.29 , Issue.6 , pp. 895-905
    • Pedersen, M.H.1    Misaridis, T.X.2    Jensen, J.A.3
  • 4
    • 0018345949 scopus 로고
    • Determining skin thickness with pulsed ultrasound
    • H. Alexander and D. L. Miller, "Determining skin thickness with pulsed ultrasound," J. Invest. Dermatol., vol. 72, no. 1, pp. 17-19, 1979.
    • (1979) J. Invest. Dermatol , vol.72 , Issue.1 , pp. 17-19
    • Alexander, H.1    Miller, D.L.2
  • 5
    • 0032262063 scopus 로고    scopus 로고
    • Structural analysis of the skin using high frequency, broadband ultrasound in the range from 30 to 140 MHz
    • M. Vogt, H. Ermert, S. el Gammal, K. Kaspar, K. Hoffmann, and P. Altmeyer, "Structural analysis of the skin using high frequency, broadband ultrasound in the range from 30 to 140 MHz," in Proc. IEEE Ultrason. Symp., vol. 2, 1998, pp. 1685-1688.
    • (1998) Proc. IEEE Ultrason. Symp , vol.2 , pp. 1685-1688
    • Vogt, M.1    Ermert, H.2    el Gammal, S.3    Kaspar, K.4    Hoffmann, K.5    Altmeyer, P.6
  • 7
  • 9
    • 29244471892 scopus 로고    scopus 로고
    • On the application of signal compression using Golay's codes sequences in ultrasound diagnostic
    • A. Nowicki, J. Litniewski, W. Secomski, and I. Trots, "On the application of signal compression using Golay's codes sequences in ultrasound diagnostic," Arch. Acoust., vol. 28, no. 4, pp. 313-324, 2003.
    • (2003) Arch. Acoust , vol.28 , Issue.4 , pp. 313-324
    • Nowicki, A.1    Litniewski, J.2    Secomski, W.3    Trots, I.4
  • 10
    • 33847115306 scopus 로고    scopus 로고
    • High frequency imaging using coded Golay transmission
    • Rotterdam, The Netherlands
    • A. Nowicki, M. Lewandowski, W. Secomski, and J. Litniewski, "High frequency imaging using coded Golay transmission," in Proc. IEEE Ultrason. Symp., Rotterdam, The Netherlands, 2005, pp. 2058-2061.
    • (2005) Proc. IEEE Ultrason. Symp , pp. 2058-2061
    • Nowicki, A.1    Lewandowski, M.2    Secomski, W.3    Litniewski, J.4
  • 11
    • 3042671174 scopus 로고    scopus 로고
    • Parameter optimization of pulse compression in ultrasound imaging systems with coded excitation
    • V. Behar and D. Adam, "Parameter optimization of pulse compression in ultrasound imaging systems with coded excitation," Ultrasonics, vol. 42, no. 10, pp. 1101-1109, 2004.
    • (2004) Ultrasonics , vol.42 , Issue.10 , pp. 1101-1109
    • Behar, V.1    Adam, D.2
  • 12
    • 1642586049 scopus 로고    scopus 로고
    • Ultrasonic biomedical technology; marketing versus clinical reality
    • F. Forsberg, "Ultrasonic biomedical technology; marketing versus clinical reality," Ultrasonics, vol. 42, pp. 17-27, 2004.
    • (2004) Ultrasonics , vol.42 , pp. 17-27
    • Forsberg, F.1
  • 13
    • 15844367336 scopus 로고    scopus 로고
    • Coded excitation for diagnostic ultrasound: A system developer's perspective
    • R. Y. Chiao and X. Hao, "Coded excitation for diagnostic ultrasound: A system developer's perspective," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 52, pp. 160-170, 2005.
    • (2005) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.52 , pp. 160-170
    • Chiao, R.Y.1    Hao, X.2
  • 16
    • 85027703845 scopus 로고    scopus 로고
    • General Purpose Computation on Graphics Hardware, ACM SIGGRAPH 2005 Course, 2005.
    • "General Purpose Computation on Graphics Hardware," ACM SIGGRAPH 2005 Course, 2005.
  • 17
    • 0038789017 scopus 로고    scopus 로고
    • Realtime 3D visualization of ultrasonic data using a standard PC
    • S. I. Nikolov, J. P. Gomez Gonzalez, and J. A. Jensen, "Realtime 3D visualization of ultrasonic data using a standard PC," Ultrasonics, vol. 41, no. 6, pp. 421-426, 2003.
    • (2003) Ultrasonics , vol.41 , Issue.6 , pp. 421-426
    • Nikolov, S.I.1    Gomez Gonzalez, J.P.2    Jensen, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.