메뉴 건너뛰기




Volumn 15, Issue 4, 2008, Pages 1190-1199

Accurate estimation of the time-of-arrival of partial discharge pulses in cable systems in service

Author keywords

Defect location; Delay estimation; Partial discharges; Power cables; Signal analysis

Indexed keywords

CABLES; DISCHARGE (FLUID MECHANICS); FLUID MECHANICS; SENSITIVITY ANALYSIS;

EID: 49449101303     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2008.4591242     Document Type: Article
Times cited : (85)

References (15)
  • 1
    • 49449110162 scopus 로고    scopus 로고
    • th Int. Conf. Insul. Power Cables (Jicable), paper No. A 4.1, 2007.
    • th Int. Conf. Insul. Power Cables (Jicable), paper No. A 4.1, 2007.
  • 2
    • 33847740252 scopus 로고    scopus 로고
    • A Novel Wavelet Transform Technique for On-line Partial Discharge Measurements Part 1: WT De-noising Algorithm
    • H. Zhang, T.R. Blackburn, B.T. Phung and D. Sen, "A Novel Wavelet Transform Technique for On-line Partial Discharge Measurements Part 1: WT De-noising Algorithm", IEEE Trans. Dielectr. Electr. Insul., Vol. 14, pp. 3-14, 2007.
    • (2007) IEEE Trans. Dielectr. Electr. Insul , vol.14 , pp. 3-14
    • Zhang, H.1    Blackburn, T.R.2    Phung, B.T.3    Sen, D.4
  • 3
    • 33645807177 scopus 로고    scopus 로고
    • Cost-Effective On-line Partial Discharge Measurements for Cables
    • Y. Zhou, Y. Qin and P. Chappell, "Cost-Effective On-line Partial Discharge Measurements for Cables", IEEE Electr. Insul. Mag., Vol. 22, No. 2, pp. 31-38, 2006.
    • (2006) IEEE Electr. Insul. Mag , vol.22 , Issue.2 , pp. 31-38
    • Zhou, Y.1    Qin, Y.2    Chappell, P.3
  • 4
    • 52049122858 scopus 로고    scopus 로고
    • Innovative asset management and targeted investments using on-line partial discharge monitoring & mapping techniques
    • CIRED, paper No. 0551
    • th Int. Conf. Electr. Distr. (CIRED), paper No. 0551, 2007.
    • (2007) th Int. Conf. Electr. Distr
    • Michel, M.1
  • 5
    • 0027697724 scopus 로고
    • Partial Discharge Part XVIII: Errors in the Location of Partial Discharges in High Voltage Solid Dielectric Cables
    • F.H. Kreuger, M.G. Wezelenburg, A.G. Wiemer and W.A. Sonneveld, "Partial Discharge Part XVIII: Errors in the Location of Partial Discharges in High Voltage Solid Dielectric Cables", IEEE Electr. Insul. Mag., Vol. 9, No. 6, 1993.
    • (1993) IEEE Electr. Insul. Mag , vol.9 , Issue.6
    • Kreuger, F.H.1    Wezelenburg, M.G.2    Wiemer, A.G.3    Sonneveld, W.A.4
  • 6
    • 51249186419 scopus 로고
    • A procedure for the modeling of nonstationary time series
    • G. Kitagawa and H. Akaike, "A procedure for the modeling of nonstationary time series", Ann. Inst. Stat. Math., Vol. 30, pp. 351-363, 1978.
    • (1978) Ann. Inst. Stat. Math , vol.30 , pp. 351-363
    • Kitagawa, G.1    Akaike, H.2
  • 7
    • 0033393307 scopus 로고    scopus 로고
    • Robust automatic p-phase picking: An on-line implementation in the analysis of broadband seismogram recordings
    • R. Sleeman and T. van Eck, "Robust automatic p-phase picking: an on-line implementation in the analysis of broadband seismogram recordings", Phys. Earth Planet. Inter., Vol. 113, pp. 265-275, 1999.
    • (1999) Phys. Earth Planet. Inter , vol.113 , pp. 265-275
    • Sleeman, R.1    van Eck, T.2
  • 8
    • 0442328684 scopus 로고    scopus 로고
    • Automatic p-wave arrival detection and picking with multiscale wavelet analysis for single-component recordings
    • H. Zhang, C. Thurber, and C. Rowe, "Automatic p-wave arrival detection and picking with multiscale wavelet analysis for single-component recordings", Bull. Seism. Soc. Am., Vol. 93, pp. 1904-1912, 2003.
    • (2003) Bull. Seism. Soc. Am , vol.93 , pp. 1904-1912
    • Zhang, H.1    Thurber, C.2    Rowe, C.3
  • 9
    • 20144383158 scopus 로고    scopus 로고
    • Strategies for reliable automatic onset time picking of acoustic emissions and of ultrasound signals in concrete
    • J.H. Kurz, C.U. Grosse, and H.-W. Reinhardt, "Strategies for reliable automatic onset time picking of acoustic emissions and of ultrasound signals in concrete", Ultrasonics, Vol. 43, pp. 538-546, 2005.
    • (2005) Ultrasonics , vol.43 , pp. 538-546
    • Kurz, J.H.1    Grosse, C.U.2    Reinhardt, H.-W.3
  • 10
    • 51849131195 scopus 로고    scopus 로고
    • Algorithms for automated arrival time estimation of partial discharge signals in power cables
    • ISH, paper No. T7-332
    • C. Herold, T. Leibfried, S. Markalous, and I. Quint, "Algorithms for automated arrival time estimation of partial discharge signals in power cables", Proc. Int. Symp. High Volt. Eng. (ISH), paper No. T7-332, 2007.
    • (2007) Proc. Int. Symp. High Volt. Eng
    • Herold, C.1    Leibfried, T.2    Markalous, S.3    Quint, I.4
  • 11
    • 49449093457 scopus 로고    scopus 로고
    • D.Gabor, Theory of communication, J. IEE Pt. III: Radio Commun. Eng., 93, pp. 429-457, 1946.
    • D.Gabor, "Theory of communication", J. IEE Pt. III: Radio Commun. Eng., Vol. 93, pp. 429-457, 1946.
  • 12
    • 0005846844 scopus 로고    scopus 로고
    • Partial discharge location as a diagnostic tool for power cables
    • M. Mashikian, "Partial discharge location as a diagnostic tool for power cables", IEEE Power Eng. Soc. Winter Meeting, pp. 1604-1608, 2000.
    • (2000) IEEE Power Eng. Soc. Winter Meeting , pp. 1604-1608
    • Mashikian, M.1
  • 15
    • 17644403522 scopus 로고    scopus 로고
    • Online calibration of high-frequency partial discharge signals in three-phase belted power cables
    • P.A.A.F. Wouters, "Online calibration of high-frequency partial discharge signals in three-phase belted power cables", IEE Proc. Sci. Meas. Technol., Vol. 152, pp. 79-86, 2005.
    • (2005) IEE Proc. Sci. Meas. Technol , vol.152 , pp. 79-86
    • Wouters, P.A.A.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.