메뉴 건너뛰기




Volumn 31, Issue 4 SPEC. ISS., 2004, Pages 737-741

Robotic pyeloplasty: Technique and results

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CATHETERIZATION; DOPPLER FLOWMETRY; HUMAN; KIDNEY PELVIS; LAPAROSCOPIC SURGERY; MORBIDITY; POSTOPERATIVE CARE; PRIORITY JOURNAL; PYELOPLASTY; ROBOTICS; STENT; SURGEON; SURGICAL TECHNIQUE; SUTURE; URETEROPELVIC JUNCTION OBSTRUCTION;

EID: 4944264980     PISSN: 00940143     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ucl.2004.06.006     Document Type: Review
Times cited : (44)

References (16)
  • 1
    • 0030899697 scopus 로고    scopus 로고
    • Open surgical exploration after failed endopyelotomy: A 12-year perspective
    • M. Gupta, O.T. Tuncay, and A.D. Smith Open surgical exploration after failed endopyelotomy: a 12-year perspective J Urol 157 1997 1613 1619
    • (1997) J Urol , vol.157 , pp. 1613-1619
    • Gupta, M.1    Tuncay, O.T.2    Smith, A.D.3
  • 2
    • 0030999834 scopus 로고    scopus 로고
    • A multicenter clinical trial investigating the use of a fluoroscopically controlled cutting balloon catheter for the management of ureteral and ureteropelvic junction obstruction
    • G.M. Preminger, R.V. Clayman, S.Y. Nakada, R.K. Babayan, D.M. Albala, and G.J. Fuchs A multicenter clinical trial investigating the use of a fluoroscopically controlled cutting balloon catheter for the management of ureteral and ureteropelvic junction obstruction J Urol 157 1997 1625 1629
    • (1997) J Urol , vol.157 , pp. 1625-1629
    • Preminger, G.M.1    Clayman, R.V.2    Nakada, S.Y.3    Babayan, R.K.4    Albala, D.M.5    Fuchs, G.J.6
  • 3
    • 0345827937 scopus 로고    scopus 로고
    • Retrograde ureteroscopic endopyelotomy
    • R. Urena, F. Mendez, and R. Thomas Retrograde ureteroscopic endopyelotomy Atlas Urol Clin 11 2003 155 163
    • (2003) Atlas Urol Clin , vol.11 , pp. 155-163
    • Urena, R.1    Mendez, F.2    Thomas, R.3
  • 5
    • 0343081496 scopus 로고    scopus 로고
    • Extraperitoneal laparoscopic repair of ureteropelvic junction obstruction: Initial experience in 15 cases
    • M.R. Ben Slama, L. Salomon, A. Hoznek, A. Cicco, F. Saint, and W. Alame Extraperitoneal laparoscopic repair of ureteropelvic junction obstruction: initial experience in 15 cases Urology 56 2000 45 48
    • (2000) Urology , vol.56 , pp. 45-48
    • Ben Slama, M.R.1    Salomon, L.2    Hoznek, A.3    Cicco, A.4    Saint, F.5    Alame, W.6
  • 8
    • 0036129413 scopus 로고    scopus 로고
    • Effect of crossing vessels on successful laparoscopic pyeloplasty using contrast-enhanced color Doppler imaging
    • F. Frauscher, G. Janetschek, A. Klauser, R. Peschel, E.J. Halpern, and L. Pallwein Effect of crossing vessels on successful laparoscopic pyeloplasty using contrast-enhanced color Doppler imaging Urology 59 2002 500 505
    • (2002) Urology , vol.59 , pp. 500-505
    • Frauscher, F.1    Janetschek, G.2    Klauser, A.3    Peschel, R.4    Halpern, E.J.5    Pallwein, L.6
  • 10
    • 0033153307 scopus 로고    scopus 로고
    • Robotic-assisted laparoscopic pyeloplasty: A pilot study
    • G.T. Sung, I.S. Gill, and T.H. Hsu Robotic-assisted laparoscopic pyeloplasty: a pilot study Urology 53 1999 1099 1103
    • (1999) Urology , vol.53 , pp. 1099-1103
    • Sung, G.T.1    Gill, I.S.2    Hsu, T.H.3
  • 11
    • 0035667656 scopus 로고    scopus 로고
    • Robotic laparoscopic surgery: A comparison of the daVinci and Zeus systems
    • G.T. Sung, and I.S. Gill Robotic laparoscopic surgery: a comparison of the daVinci and Zeus systems Urology 58 2001 893 898
    • (2001) Urology , vol.58 , pp. 893-898
    • Sung, G.T.1    Gill, I.S.2
  • 12
    • 0036754182 scopus 로고    scopus 로고
    • Anderson-Hynes dismembered pyeloplasty performed using the daVinci robotic system
    • M.T. Gettman, R. Neururer, G. Bartsch, and R. Peschel Anderson-Hynes dismembered pyeloplasty performed using the daVinci robotic system Urology 60 2002 509 513
    • (2002) Urology , vol.60 , pp. 509-513
    • Gettman, M.T.1    Neururer, R.2    Bartsch, G.3    Peschel, R.4
  • 13
    • 0036855986 scopus 로고    scopus 로고
    • Laparoscopic pyeloplasty: Comparison of procedures performed with the daVinci robotic system versus standard techniques
    • M.T. Gettman, R. Peschel, R. Neururer, and G. Bartsch Laparoscopic pyeloplasty: comparison of procedures performed with the daVinci robotic system versus standard techniques Eur Urol 42 2002 453 458
    • (2002) Eur Urol , vol.42 , pp. 453-458
    • Gettman, M.T.1    Peschel, R.2    Neururer, R.3    Bartsch, G.4
  • 14
    • 1542382904 scopus 로고    scopus 로고
    • DaVinci robot assisted Anderson-Hynes dismembered pyeloplasty: Technique and 1 year follow-up
    • W. Bentas, M. Wolfram, R. Brautigam, M. Probst, W.D. Beecken, and D. Jonas daVinci robot assisted Anderson-Hynes dismembered pyeloplasty: technique and 1 year follow-up World J Urol 21 2003 133 138
    • (2003) World J Urol , vol.21 , pp. 133-138
    • Bentas, W.1    Wolfram, M.2    Brautigam, R.3    Probst, M.4    Beecken, W.D.5    Jonas, D.6
  • 15
    • 0036292129 scopus 로고    scopus 로고
    • Comparison of robotic versus laparoscopic skills: Is there a difference in the learning curve?
    • P. Yohannes, P. Rotariu, P. Pinto, A.D. Smith, and B.R. Lee Comparison of robotic versus laparoscopic skills: is there a difference in the learning curve? Urology 60 2002 39 45
    • (2002) Urology , vol.60 , pp. 39-45
    • Yohannes, P.1    Rotariu, P.2    Pinto, P.3    Smith, A.D.4    Lee, B.R.5
  • 16
    • 0037344073 scopus 로고    scopus 로고
    • Laparoscopic Anderson-Hynes dismembered pyeloplasty using the daVinci robot: Technical considerations
    • P. Yohannes, and S.C. Burjonrappa Laparoscopic Anderson-Hynes dismembered pyeloplasty using the daVinci robot: technical considerations J Endourol 17 2003 79 83
    • (2003) J Endourol , vol.17 , pp. 79-83
    • Yohannes, P.1    Burjonrappa, S.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.